Too much water being
used in house
•
Reduce water use
•
Check for leaky fixtures
•
Groundwater
infiltrating
into tanks
•
Drain ground and surface
water away from tanks
•
Find and fix aking openings
le
•
Water-tight tanks if possible
•
Pump
failure
•
Check pump operation by
running manually
•
Replace pump if necessary*
•
Fuse breaker tripped
•
Check breaker and reset
•
Pump or float power
cord unplugged
•
Check electrical plugs
•
Controls
malfunctioning
•
Call system installer and/or
electrician
•
Control floats tangled by
other parts in the
chamber
•
Untangle and secure cords
•
Ensure all floats swing freely
Alarm ounding
Sewage may back up
in
o
S
to house or break
ut on ground
•
Debris on floats and
power cords causing
improper function
•
Clean floats and cords by
hosing/scraping off
•
Pump tank if necessary
•
Sewage backup in
house
•
See “Sewage Backing Up In
House” on previous page
•
Sewage surfacing in
yard
•
See “Sewage Breaking Out
On Ground” on previous
page
•
Roof vent pipe blocked
•
Locate and clear roof vent
pipe(s)
•
Improper
plumbing
•
Repair plumbing
Sewage Smells in
House
Toxic gases can be
flammable or make
people sick
•
Unsealed
ejector
sump
pump
•
Locate and seal ejector sump
properly
•
Someone
else’s
septic
problems
•
Talk to your neighbor about
correcting the problem
•
If public health is threatened
call county
•
Sewage surfacing in
yard
•
Repair or replace drainfield
•
Inspection
port
caps
damaged or removed
•
Replace damaged caps
Sewage Smells
Outside
Nuisance
•
Tank lids not sealed or
improperly installed
•
Repair or replace lids with
ones that seal properly*
Float Chattering -
Pump turns off
and on rapidly.
e
meter
•
Nuisance
•
Inaccurat
readings
•
Mercury float switch
•
Replace chattering float
switch with correct
‘mechanical’ float sw
installed to control pump
itch*
•
Improper
construction
•
Check system for problems*
•
Transport
line
doesn’t
drain between doses
•
Remove check valve from
line or install anti-siphon
device if pumping downhill*
•
Water not flowing
through system often
enough
•
Increase frequency of pump
cycling
Pipes or system
freezes in winter
top
The system may s
functioning causing
breakouts or backups
•
Compacted ground not
insulating pipes or
drainfield
•
Keep people and vehicles off
area
*
Call a professional
- 29 -
Содержание Septic System