Mase IS 10.2 Скачать руководство пользователя страница 19

IS 8 - 9.5  9 - 10.2

ma

s

e

31

GB

5.8 Coolant replacement

Yearly change the coolant in the closed-circuit cooling

system.

Connect a 20-30 cm long rubber tube [Fig. 10, Ref. 2] to

the drain tap [Fig. 10, Ref. 1] located on the engine base

to facilitate collection of the used coolant in a collection

receptacle  [Fig. 10, Ref. 3]. Open the tap and completely

drain the closed-circuit cooling system.

When the operation has been completed, close the tap

and fill the circuit with new coolant.

Dispose of the used coolant in an appropriate manner

as it is a polluting product.

Take the used coolant to special collection centres

responsible for disposal.

5.9  Zinc anode replacement

To protect the water/air heat exchanger [Fig. 11, Ref. 1]

and the water/coolant heat exchanger [Fig. 11, Ref. 2]

against galvanic current, two sacrificial zinc anodes [Fig.

11, Ref. 4] have been inserted inside them. Periodically

check their state of wear and, if necessary, replace them

in order to prevent that the galvanic current irreparably

corrodes  the  heat  exchanger.  It  is  recommended  to

check the zinc anodes at least once a month when the

generator is new to check how fast consumption is, to

then be able to act accordingly.

It is, however, opportune to replace the zinc anodes at

least once a year.

Fig. 11 shows the points where the zinc anodes are

positioned.

5.10 Seawater pump maintenance

At least once a year check the integrity of the rubber rotor

of the seawater pump [Fig. 12, Ref. 1].

Before opening the seawater pump to inspect the rotor,

drain the seawater from the cooling system as described

in Paragraph 5.7.

To access the rotor, remove the cover [Fig. 12, Ref. 2] and

with the aid of a pair of pliers extract the rotor pulling it out

with force. To remount a new rotor, repeat the operations

described above in reverse order.

5.11 Alternator maintenance

The alternator used on this model of generator is type

synchronous,  self-energised,  with  electronic  voltage

regulation. This model alternator, without manifold and

brushes,  does  not  require  particular  maintenance

operations. The periodic checks and maintenance are

limited to removing any traces of damp and oxidation

which might damage it.

5.12 Battery maintenance

For starting all the generator models, it is recommended

to  use  an  80  A/h  battery  for  ambient  temperatures

exceeding 0ºC, and 100 A/h for lower temperatures.

Before  installing  a  new  battery  it  is  important  that  it

undergoes a full charging cycle.

At least once a month check the level of the electrolyte

and,  if  necessary,  top  up  with  distilled  water.  If  the

generator  is  not  to  be  used  for  a  long  period,  it  is

recommended to disconnect the battery and store it in a

dry place at a temperature over 10ºC and to carry out a full

charging cycle once a month.

If the battery is left completely flat for long periods,

there is a risk of irreparably damaging it.

The positive terminal of the battery must be protected with

Vaseline to prevent corrosion and the formation of oxide.

For  top-ups  with  sulphuric  acid,  ready  solutions

must be used.

The battery top-up operations with distilled water or

with acid must be carried out with rubber gloves and

protective glasses to prevent accidental contact of

the sulphuric acid with the skin.

In the event of accidental contact, thoroughly wash

the part affected with soap and water and consult a

doctor.

Before recharging the battery check the level of the

electrolyte and, if necessary, fill up with distilled

water. This operation must be repeated when the

recharging cycle has been completed.

5.13 Periods of inactivity

Start  up  the  generator  at  least  once  a  month.  If  the

generator is not to be used for a long time, the following

operations must be carried out:

-

Change the engine oil

-

Replace the oil filter cartridge (see par. 5.2)

-

Replace the fuel filter cartridge (see par. 5.4)

-

Remove the injectors and pour 2 cc engine oil into

each cylinder and let the engine turn over a few times,

manually operating the drive shaft pulley. Remount

the injectors.

-

Replace the zinc anodes (see par. 5.9)

-

Through the seawater intake pipe aspirate some anti-

freeze  whose  function  is  to  protect  the  heat

exchangers against low temperatures and to lubricate

Содержание IS 10.2

Страница 1: ...SAGE AND MAINTANCE MANUAL MANUEL D INSTRUCTIONS ET D ENTRETIEN GEBRAUCHSANWEISUNG UND WARTUNGSVORSCHRIFTEN MANUAL USO Y MANTENIMENTO GEBRUIKS EN ONDERHOUDSHANDLEIDING IS 8 IS 9 5 50 Hz 60 Hz IS 9 IS 1...

Страница 2: ...hat the generators model is Codice Code Descrizione Model Matricola Serial N E conforme alle disposizioni delle Direttive di seguito elencate CEE 89 392 come emendata delle Direttive CEE 91 368 e CEE...

Страница 3: ...IS 8 9 5 9 2 10 2 mase 3 10 2 1 2 3 5 6 7 8 9 4...

Страница 4: ...IS 8 9 5 9 2 10 2 4 mase 3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 18 17 19 20 21 22 23 24...

Страница 5: ...IS 8 9 5 9 2 10 2 mase 5 12 9 8 7 6 10 4 5 1 2 3 4 5 11 1 3 2 2 4 5...

Страница 6: ...IS 8 9 5 9 2 10 2 6 mase 1 1 TAB A 6 2 7 3 2 S A E Service Grade 30 20 10 0 10 20 30 40 Ambient temperature o C 8...

Страница 7: ...IS 8 9 5 9 2 10 2 mase 7 9 10 1 2 3...

Страница 8: ...IS 8 9 5 9 2 10 2 8 mase 11 12 1 2 3...

Страница 9: ...IS 8 9 5 9 2 10 2 mase 9 13 IS 8 9 5 IS 9 2 10 2...

Страница 10: ...IS 8 9 5 9 2 10 2 10 mase 14 IS 8 9 5 P I IS 9 2 10 2 P I...

Страница 11: ...IS 8 9 5 9 2 10 2 mase 11...

Страница 12: ...Low oil pressure protection 27 4 2 Highwatertemperatureprotection 27 4 3 Alternatoroverheatingprotection 27 4 4 Alternatoroverheatingprotection 28 4 5 Protection against short circuit of the low volta...

Страница 13: ...g economy and a longer life of the generator To facilitate consultation it has been divided into sections identifying the main concepts For a quick look at the topics consult the index on Page 23 Symb...

Страница 14: ...ght engine running 7 OIL light low oil pressure 8 C light high engine temperature 9 BATT light battery charger operating 10 C light high alternator temperature 11 Glow plugs not present 12 Fuel leak v...

Страница 15: ...tlight Fig 4Ref 7 whenon indicates that the engine oil pressure is insufficient Red Fig 4Ref 10 pilotlight whenon indicatesthat thetemperatureofthecoolantorthewatercirculating in the heat exchangers i...

Страница 16: ...nd the alternator to cool down 4 PROTECTIONS TheIS8andIS9 5generatorsareequippedwithaseries of protections which safeguard them against improper use and operating problems When the generator stops bec...

Страница 17: ...tres Top ups and filling with engine oil is carried out through the hole Fig 3 Ref 17 Tochangetheoilintheoilsump removethedipstick Fig 7 Ref 2 and operate the special extraction pump Fig 3 Ref 12 afte...

Страница 18: ...ent pour coolant into the expansion tank taking care not to exceed the maximum level index Never open the cap of the expansion tank Fig 3 Ref 11 or coolant tank Fig 3 Ref 20 when the engine is hot to...

Страница 19: ...oes not require particular maintenance operations The periodic checks and maintenance are limited to removing any traces of damp and oxidation which might damage it 5 12 Battery maintenance For starti...

Страница 20: ...Thestartermotorturnsbutthemainenginedoesnot start Check that there is fuel in the tank fill up Checkifthestopelectromagnetisinthefiringposition consultServiceCentre Bleedtheairbubblesfromthefuelcircu...

Страница 21: ...ttery Ah V Battery charger Ah V Starter KW V Max inclination Water pump flow l min gl min 25 6 6 28 6 1 25 6 6 28 6 1 50 Hz 60Hz 50 Hz 60Hz Type Cooling Voltage V 115 230 120 240 115 230 120 240 Frequ...

Страница 22: ...uge 11 Oil pressure gauge 12 Water temperature gauge 13 Fuel pump 14 High water temperature sensor 15 High coolant temperature sensor 16 Oil pressure switch 17 DC alternator 18 Stop electromagnet 19 S...

Страница 23: ...IS 8 9 5 9 2 10 2 mase 79 Rev Rel FIG 1 7 IS 8 9 5 9 10 2 MOTORE ENGINE...

Страница 24: ...P 20 71059 1 VASO ESPANSIONE TAPPO SUB TANK PLUG 21 010664 1 STAFFA SUPPORTO FILTRO NAFTA FUEL FILTER BRACKET SUPPORT 22 11280 2 RACC OCCHIO D 12 PORTAGOM D 8 UNION 23 10817 1 RACC OCCHIO D 14 PORTAGO...

Страница 25: ...TTO ROTORE ROTOR BALL BEARING 6 010758 1 FASCIA PROTEZIONE ALTERNATORE ALTERNATOR PROTECTION BAND 7 910317 1 STATORE STATOR 8 70229 cm 60 GUARNIZIONE ADESIVA 10X3 ADHESIVE GASKET 10X3 9 71197 1 O RING...

Страница 26: ...IS 8 9 5 9 2 10 2 82 mase Rev Rel FIG 3 7 CASSA FRAME IS 8 9 5 9 10 2...

Страница 27: ...STING CLOSURE 12 71078 1 MANIGLIA POCKET PULL HANDLE 13 41628 1 PIANALE COMPENSATO WOODEN BASE 14 70210 cm 4 GUARNIZIONE ADESIVA 20X3 ADHESIVE GASKET 15 71182 cm 20 CHIUSURA A STRAPPO TUG CLOSING 16 7...

Страница 28: ...IS 8 9 5 9 2 10 2 84 mase Rev Rel FIG 4 7 GRUPPO MARINIZZAZIONE SEA WATER IS 8 9 5 9 10 2...

Страница 29: ...ASKET 20 011388 1 MISCELATORE MIXER 21 30253 1 TERMOCONTATTO VDO 70 RIF 867 THERMAL SWITCH 22 70873 mt 0 2 TUBO SPIRALBENZ D 50 PIPE 23 011390 1 CURVA SCARICO D 50 60 D 50 90 EXHAUST BEND 24 11281 1 F...

Страница 30: ...L 2 32393 1 MODULO PROTEZIONE MOTORE ENGINE PROTECTION MODULE 3 32402 1 INTERRUTTORE START 0 STOP START 0 STOP BUTTON 4 30270 1 CALOTTA PER T11 211 TIPO H THERMAL SWITCH PROTECTION 5 30474 1 CONTAORE...

Страница 31: ...A DIST CON STRUMENTI REMOTE CONTROL PANEL KIT WITH INSTRUMENTS 1 010879 1 QUADRO COMANDO A DISTANZA REMOTE CONTROL PANEL WITH INSTRUMENTS 1a 012396 1 PANNELLO PANEL 1b 41669 1 ADESIVO LABEL 1c 32402 1...

Страница 32: ...RUMENTS IS 8 9 5 9 10 2 5LI RG 4 W HVFUL LRQH HVFULSWLRQ 010881 1 KIT COMANDO A DISTANZA REMOTE CONTROL PANEL KIT 1 010882 1 QUADRO COMANDO A DISTANZA REMOTE CONTROL PANEL 1a 012395 1 PANNELLO PANEL 1...

Страница 33: ......

Страница 34: ...Mase Generators S p a Via Tortona 345 47023 Cesena FC ITALY Tel 39 0547 35 43 11 Fax 39 0547 31 75 55 www masegenerators com e mail mase masegenerators com...

Отзывы: