NMM Series
5
The warranty conditions will only be valid when all the
instructions about installation and start-up operations
of the pump unit are taken into account.
2.4. Test
All Pumps are dispatched for sale when all the
performance and pressure tests are completed. Proper
assurance of material and fault-free operation of
pumps whose performance tests are made is under the
warrantyof
MAS DAF MAKINA SANAYI A.Ş.
2.5. Pressure Limit
Pressure at the discharge flange must not exceed 10
Bar. A special order is necessary for applications with
higher pressures.
3. SAFE OPERATING CONDITIONS
This manual contains main safety instructions for the
installation, operation and maintenance. It must be
read by the personnel who are responsible for installa-
tion and operation. This manual should always be kept
near the installation location. It is important to comply
with safety precautions stated in page 1 along with the
general safety instructions as well as preventive
measures repeated in other sections of this manual.
3.1. Training of Personnel
Installation, operation and maintenance personnel
must have necessary knowledge in order to accomplish
the given job. The responsibility, adequacies and
controlling duties of such personnel must be
determined by the costumer. It has to be certain that
these personnel comprehend totally the content of the
operating manual.
If the personnel do not have enough knowledge,
required training must be given by the costumer. If
training support is needed by the costumer, it will be
provided by the manufacturer/seller.
CAUTION
Untrained personnel and unwillingness to comply with
safety instructions may be risky for both machine and
environment.
MAS DAF MAKINA SANAYI A.Ş.
is not
responsible for this kind of damages.
3.2. Hazardous Conditions That May Occur When One
does not Comply With the Safety Instructions
Incompliance with safety regulations may put the
personnel, the environment and the machine in danger
and thus may cause damages. Incompliance with safety
regulations may give rise to situations listed below.
Important operational functions of the factory may
stop.
Maintenance may get difficult.
One may get injured by electrical, mechanical or
chemical hazards.
3.3. Safety Measures for Operator
Dangerous, hot or cold components in the pump area
must be covered so that one cannot touch them.
Moving components of the pump must be covered so
that one cannot touch them. Those covers must not be
dismounted while the pump is running. Dangers that
results from electrical connections must be removed.
To get more information about this subject, you can
refer to domestic electrical instructions.
3.4. Safety Measures for Maintenance and Installation
The costumer must assure that all maintenance, check
and installment tasks are performed by qualified
personnel. Repair work must only be performed while
the machine is not running.
The pump and its auxiliary system must be cleaned
thoroughly if it contains hazardous liquids. At the end of
the repair work, all safety and protective equipment
must be re-installed.
3.5. Spare Parts Replacement
Replacement of spare parts and all modifications must
be done after contacting with the manufacturer. Spare
parts and accessories certified by the manufacturer are
important for the safe operation of the system.
Notice: MAS DAF MAKINA SANAYI A.Ş.
is not responsible
from the usage of improper spare parts.
4. TECHNICAL INFORMATION
4.1. Design
These are close coupled, single stage, single suction
with a horizontal opening and a vertical discharge
opening volute type (with horizontal shaft) pumps. They
have closed radial impellers and their casing sizes are in
accordance to DIN 24255 and EN 733 standards.
4.1.1. Locations of Flange – Flanges
Suction Flanges: In axial direction
DN50-DN150
Discharge Flanges: Radially upward DN32-DN125
Standard of Flanges:
TSE EN 1092-2
4.1.2. Connection of Pump and Motor
Motor is close coupled to the pump with a rigid coupling
using and an adapter and flange. In this way, the shafts
of the motor and pump constitute a complete unit.
Содержание NMM Series
Страница 1: ...NMM SERIES Operating Manual Monoblock Centrifugal Pumps May 2021 Revision No ...
Страница 2: ...2 ...