background image

6

that may occur due to difference in potential 
between charger terminals and battery termi-
nals. Note! Make sure the charger terminals are 
not short-circuited and ensure that the polarity 
is correct.

•  If the charger is equipped with battery clips; 

fi rst connect the positive clip (RED) to the 
positive battery pole, then connect the other 
clip (BLACK) to the battery’s negative pole.

•  To charge batteries in vehicles; fi rst connect 

the positive clip (RED) to the positive battery 
pole (The one not connected to the vehicles 
chassis), then connect the other clip (BLACK) to 
the vehicle’s chassis - a good distance from the 
battery and fuel system (fuel hoses, fuel pump 
etc.).

•  The charge cycle starts when the charger is 

connected to the mains.

•  If the charger is disconnected from the mains 

voltage during a charge cycle the charger will 
start a new charge cycle when it is reconnected 
to the mains.

•  When charging is complete, disconnect the 

charger from the mains before removing 
battery connections.
If the charger is equipped with battery clips:
fi rst disconnect the clip from the battery’s 
positive pole then the other from the negative 
battery pole/vehicle chassis, in this order.

•  The recommended minimum battery capacity 

for which the specifi c charger can be used 
vary from battery to battery. Some do not have 
a capacity restriction at the specifi ed boost 
voltage level while others have restrictions. 
Please follow the datasheet and recommen-
dations from the battery manufacturer. In 
our tables we use typical C/5 as a maximum 
charge current for Lead Acid cells. C/5 means 
that charge current for a 10Ah battery should 
be max 2A. Thus the typical minimum capacity 
recommendation is then 10Ah for a 2A charger. 
For max battery capacity we have used 50 
times charge current for chargers with timer 
(and/or uC) and 50 times current detection 
levels for chargers using only this termination 
method. For a 2A charger with 0.25A current 
detection level the max capacity recommended 
will be 50 x 0.25A = 12.5Ah. Again this is 
just typical recommendations. Please read 
recommendations and datasheets from battery 
manufacturer.

Содержание 205140

Страница 1: ...w mascot no downloads usermanuals Bruksanvisning Käyttöohjeet Bedienungsanleitung Mode d emploi Manual de instrucciones Istruzioni per l uso Doc no 5140C Part No 205140 04 12 2017 MASCOT ELECTRONICS AS P O Box 177 N 1601 Fredrikstad NORWAY Phone 47 69 36 43 00 Telefax 47 69 36 43 01 E mail sales mascot no Web www mascot no ...

Страница 2: ...RIC SHOCK READ THROUGH THESE INSTRUCTIONS PRIOR TO USING THE PRODUCT CAREFULLY FOLLOW THESE INSTRUCTIONS WHEN USING THE PRODUCT RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE compound and is dust tight and protected against the effects of temporary immersion in water according to standard EN IEC 60529 but must not be immersed in water for longer periods of time Products marked with the double squa...

Страница 3: ...emoval of the products mains supply should an operational error occur during use If the product has a detachable mains cord the appliance coupler may be used as a disconnect device The product is switched on by inserting the mains plug into the mains socket and switched off by disconnecting the mains plug from the mains socket The product may be connected to an IT type mains supply For use in U S ...

Страница 4: ...may not be used in home healthcare environment unless they are permanently wired to the building installation Installation must only be carried out by qualified service personnel following the below instructions The protective earth conductor must be min 0 75 mm2 Connect the protective earth conductor to the external protective earthing system Verify that the protective earth terminal used is conn...

Страница 5: ...rs result in a fuse blowing leaving the charger useless When charging batteries other than vehicle batteries it is recommended that you connect the charger to the mains before connection is made to the battery This will reduce the sparks Cautions to observe prior to charging Lead Acid batteries This product complies with the requirements to electromagnetic compatibility for medical electric equipm...

Страница 6: ...ore removing battery connections If the charger is equipped with battery clips first disconnect the clip from the battery s positive pole then the other from the negative battery pole vehicle chassis in this order The recommended minimum battery capacity for which the specific charger can be used vary from battery to battery Some do not have a capacity restriction at the specified boost voltage le...

Страница 7: ...50V 13A BS 1363 AUS 250V 10A AS NZS 3112 Mains Cord Set is available on request if you wish your product to be DeskTop How to connect exchangeable DC output plugs 1 To connect for desired polarity both plug ends are clearly marked 2 When connected the female plug is also marked on each side to identify plug polarity 3 Shows the center polarity of the plug 3 12 3 1 2 ...

Страница 8: ... The LED indication on the charger is ORANGE The battery is charged to its full capacity at the end of this step STEP 3 FLOAT CHARGE The LED indication on the charger is GREEN and the battery is fully charged The charger is in standby mode The charge voltage is at standby level and the charger may remain connected to the battery The charger will return to boost charging if the battery is used A lo...

Страница 9: ...dicator charges to yellow The charger stays in this mode until the charge current decreases to charge termination level The battery is charged to its full capacity at the end of this step STEP 3 FLOAT CHARGE The LED indication on the charger is GREEN and the battery is fully charged The charger is in standby mode The charge voltage is at standby level and the charger may remain connected to the ba...

Страница 10: ...r mode indicated by the YELLOW LED and will remain in this mode until time interval is completed The battery is charged to its full capacity at the end of this step STEP 3 FLOAT CHARGE The LED indication on the charger is GREEN and the battery is fully charged The charger is in standby mode The charge voltage is at standby level which means that the charger can continue to be connected to the batt...

Страница 11: ... charger is in standby mode The charge voltage is at standby level and the charger may remain connected to the battery The charger will return to boost charge if the battery is used BATTERY NOT CONNECTED INDICATIONS Battery not connected is indicated by FLASHING GREEN Yellow Yellow Green INDICATOR FLASHING YELLOW INDICATOR GREEN Charge Voltage Charge Current INDICATOR YELLOW Charge Voltage Battery...

Страница 12: ...y charged The charger is in standby mode The charge voltage is at standby level and the charger may remain connected to the battery The charger will return to boost charge if the battery is used BATTERY NOT CONNECTED INDICATIONS Battery not connected is indicated by FLASHING GREEN In this mode charger will apply short pulses attempting to wake up deeply discharged batteries ERROR INDICATIONS 2 red...

Страница 13: ...A 44 1V 44 1V 0 4A 44 1V 0 4A 41 1V 250mA 4Ah 12 5Ah 0 6A 58 8V 58 8V 0 25A 58 8V 0 25A 54 8V 100mA 3Ah 5Ah Input voltage Charge LED indicator 6V 12V 24V 36V 48V 2240 P 2241 P 100 240Vac 50 60Hz max 0 35A Orange CC ch Orange CV ch Green Float ch Rec batt capacity 1 3A 7 35V 7 35V 250mA 6 85V 250mA 6 5Ah 12 5Ah 1A 14 7V 14 7V 250mA 13 7V 250mA 5Ah 12 5Ah 0 56A 29 4V 29 4V 250mA 27 4V 250mA 2 8Ah 12...

Страница 14: ... 284X P 314X P 220 240Vac 50 60Hz Orange CC ch Orange CV ch Yellow CV ch Green Float ch Rec batt capacity 8 5A 7 35V 7 35V 4 25A 7 35V 4 25A 6 85V 1 6A 42 5Ah 80Ah 7A 14 7V 14 7V 3 5A 14 7V 3 5A 13 7V 1 6A 35Ah 80Ah 3 5A 29 4V 29 4V 1 7A 29 4V 1 7A 27 4V 0 8A 17 5Ah 40Ah 2 3A 44 1V 44 1V 1 1A 44 1V 1 1A 41 1V 0 5A 11 5 25Ah 1 7A 58 8V 58 8V 0 9A 58 8V 0 9A 54 8V 0 4A 8 5Ah 20Ah 324X P 110 120Vac 2...

Страница 15: ...ch Yellow Timer CV ch Green Float ch Rec batt capacity N A 4A 14 7V 14 7V 4A 2h 13 8V 20Ah 200Ah 2A 29 5V 29 5V 2A 2h 27 6V 10Ah 100Ah 1 4A 44 1V 44 1V 1 4A 2h 41 4V 7Ah 70Ah 1A 58 8V 58 8V 1A 4h 54 8V 5Ah 50Ah 9840 220 240Vac 50 60Hz Orange CC ch Yellow Timer CV ch Green Float ch Rec batt capacity 5A 7 35V 7 35V 5A 2h 6 85V 25Ah 250Ah 5A 14 7V 14 7V 5A 2h 13 7V 25Ah 250Ah 2 5A 29 4V 29 4V 2A 2h 2...

Страница 16: ...A 29 4V 29 4V 10A 4h 27 4V 50Ah 500Ah 6 7A 44 1V 44 1V 6 7A 4h 41 1V 33 5Ah 335Ah 5A 58 8V 58 8V 5A 4h 54 8V 25Ah 250Ah 2640 per channel 220 240Vac 50 60Hz Orange CC ch Yellow Timer CV ch Green Float ch Rec batt capacity 10A 7 35V 7 35V 10A 4h 6 85V 50Ah 500Ah 10A 14 7V 14 7V 10A 4h 13 7V 50Ah 500Ah 5A 29 4V 29 4V 5A 4h 27 4V 25Ah 250Ah 3 3A 44 1V 44 1V 5A 4h 41 1V 16 5Ah 165Ah 2 5A 58 8V 58 8V 2 ...

Страница 17: ...0Vac 50 60Hz Yellow CC ch Flash Yellow CV ch Green Float ch Rec batt capacity 5A 7 35V 7 35V 1 5 5A 4h 6 85V 0 5A 25Ah 250Ah 5A 14 7V 14 7V 1 5 5A 4h 13 7V 0 5A 25Ah 250Ah 2 5A 29 4V 29 4V 0 6 2 5A 4h 27 6V 0 2 5A 12 5Ah 125Ah 1 7A 44 1V 44 1V 0 4 1 7A 4h 41 1V 0 1 6A 8 5Ah 85Ah 1 2A 58 8V 58 8V 0 3 1 2A 4h 54 8V 0 1 2A 6Ah 60Ah 2245 220 240Vac 115Vac 50 60Hz Yellow CC ch Flash Yellow CV ch Green ...

Страница 18: ...loat ch Rec batt capacity 2 7A 7 35V 7 35V 0 5 2 7A 4h 6 85V 0 2 7A 13 5Ah 135Ah 2A 14 7V 14 7V 0 5 2A 4h 13 7V 0 2A 10Ah 100Ah 1A 29 4V 29 4V 0 25 1A 4h 27 4V 0 1A 5Ah 50Ah 0 65A 44 1V 44 1V 0 15 0 65A 4h 41 1V 0 0 65A 3 25Ah 32 5Ah N A 3540 230Vac 50 60Hz Yellow CC ch Flash Yellow CV ch Green Float ch Rec batt capacity N A 20A 14 7V 14 7V 2 5 20A 4h 13 7V 0 20A 100Ah 1000Ah 10A 29 4V 29 4V 1 4 1...

Отзывы: