EXR
Coil
VALVE AND PUMPING ROD
ASSEMBLY
FIG. 13
After having overhauled or replaced the
valve unit and after having cleaned the
inside of the tube, reassemble. Assemble
valve components, in correct sequence:
washer
(12)
, valve
(13)
and covering
(14)
.
Then fit pumping rod
(10)
with seal ring
(9)
and rebound spring
(11)
into the valve
assembly.
FIG. 14
Fit this assembly into the stanchion tube and
properly seat the valve assembly
(C)
.
Insert the stop ring
(22)
.
CROWN AND STANCHIONS
ASSEMBLY
FIG. 15
Fit the crown and stanchions assembly
(1)
- with the dust seals in place - gently into the
sliders seals.
WARNING:
to avoid any dam-
ages to sealing surfaces, keep the
stanchions duly lubricated and squared
into the sliders.
Press the crown and stanchions assembly
fully down and check that threaded ends of
pumping elements
(10)
are coming out
through the bottom of the sliders.
Check to see that the stanchions slide unre-
stricted by cycling the fork up and down
several times.
The tube should slide freely inside the seal
assembly without any side play. In the event
it is too hard or too soft, repeat the previous
steps described above and check compo-
nents to ensure they are not damaged.
Seat the dust seals
(15)
on top of the
sliders.
10
12
13
14
11
9
22
C
1
15
15