background image

12

!

CAUTION

Step 1: Removing the Door and Hinges

Hold the door secure in the closed position and remove 

Hinge Pin from the Upper Hinge using a 1/8” Hex Key tool. 

Slowly remove the door by sliding outward away from the 

cabinet and lift to remove off the Lower Hinge. If reversing 

the door, remove hinges from cabinet per Door Reversal 

Instructions.

Remove the hinge bushing from the adaptor plate. A new 

bushing is included in the literature pack with your unit. 

Cut and prepare panels according to the information 

provided in the Integrated Panel Dimensions section. 

It is important to use the factory provided grille that came 

with the product to assure proper air flow is maintained 

through the condenser. The use of a custom grille is not 

recommended and will void the warranty.

INTEGRATED DOOR PANEL INSTALLATION

Step 2: Remove the Door Gasket

With the door laying on a flat surface and starting at a 

corner of the door, remove the magnetic door gasket from 

the interior side of the door. Set the gasket aside on a flat 

surface. 

There are 10 holes in the gasket retainer extrusions (3 on 

each side and 2 at the top and bottom) which are used to 

fasten the panel to the front of the door. The screws are 

provided in the literature pack.

Step 3: Assemble the Panel to the Door

The preferred method of attaching the panel to the door 

is to clamp the panel to the door so it cannot move while 

drilling the screw pilot holes. Use bar clamps or "C" clamps 

with pads on the clamping surfaces that will not mar the 

panel or the door. The custom panel should be flush with 

the top of the door and centered along the width of the 

door. Drill holes through the gasket extrusion using the 10 

holes as pilot holes. Use the drill size from the chart in the 

table below being careful not to drill through the front sur-

face of the panel. Fasten the panel to the door with the 10 

screws provided in the literature pack. Remove the clamps 

and replace the gasket in the gasket extrusion channels of 

the door. Some force may be required to seat the gasket 

into the channels. Be sure the gasket corners are seated 

properly.

Integrated panel 

flush with top of 

door

Integrated panel 

flush with top of 

door

Holes in gasket 

container

Material Type

#10 Wood Screw 

Hardwood

1

8

" (3.2 mm) Diameter. Pilot Hole

Softwood

7

64

 (2.8 mm) Diameter. Pilot Hole

9

Содержание MLWD224

Страница 1: ...OWNERS GUIDE MARVEL UNDERCOUNTER REFRIGERATION T H E O R I G I N A L R E F R I G E R A T I O N E X P E R T S S I N C E 1 8 9 2 F O R M O D EL M L W D 2 2 4...

Страница 2: ...lem free installation and operation WARNING WARNING You can be killed or seriously injured if you do not follow these instructions WARNING State of California Proposition 65 Warning This product conta...

Страница 3: ...g the anti tip device Integrated Panel Dimensions Integrated Panel Installation Maintenance Care and Cleaning Extended Non Use Operating Instructions Interior Adjustments Energy Savng Tips Service Obt...

Страница 4: ...lace The owners manual is shipped inside the product in a plastic bag along with the warranty registration card and other accessory items Important Keep your carton and packaging until your appliance...

Страница 5: ...rrupters GFCI are prone to nui sance tripping which will cause the appliance to shut down GFCI s are generally not used on circuits with power equip ment that must run unattended for long periods of t...

Страница 6: ...ith the end of the 211 2 54 6 cm line Rear of cabinet line 5 Fasten the anti tip bracket to the floor using the supplied screw See Figure 15 6 Slide the cabinet back into position making sure the rear...

Страница 7: ...nti tip bracket is used the mini mum adjusted height of the cabinet is increased by 3 8 9 mm Figure 15a V notches in bracket V notches in bracket Figure 15 211 2 54 6 cm Front of cabinet line Rear Lev...

Страница 8: ...uct is pressed against the adjacent cabinet use a 5 8 thick panel The window cutout is for glass door models only Do not use a solid door panel on a glass door model INTEGRATED PANEL DIMENSIONS Top of...

Страница 9: ...ket retainer extrusions 3 on each side and 2 at the top and bottom which are used to fasten the panel to the front of the door The screws are provided in the literature pack Step 3 Assemble the Panel...

Страница 10: ...or swing reinstall hinges per Door Reversal Instructions Carefully slide lower hinge bushing over bottom hinge pin Install the new upper hinge bushing into adaptor plate Align hinge bushing with top h...

Страница 11: ...the extended cabinet mounted shelf exten sions back into the cabinet To re install a shelf Pull out the cabinet mounted shelf extensions to assist the engagement with the wire rack shelf Insert the wi...

Страница 12: ...cuit Not shared with other appliances 5 When initially loading your new product or whenever large quantities of warm contents are placed within refrigerated storage compartment minimize door openings...

Страница 13: ...rsonal preference and provides the proper storage for your stored contents 11 When on vacation or away from home for extended pe riods set the appliance to warmest acceptable tem perature for the stor...

Страница 14: ...low ice to thaw naturally 4 Clean and dry the interior of the unit Ensure all water has been removed from the unit 5 The door must remain open to prevent formation of mold and mildew Open door a minim...

Страница 15: ...rt section In all correspondence regarding service be sure to give the service number serial number and proof of purchase Try to have information or description of nature of the problem how long the a...

Страница 16: ...r and part description Some parts will require color or voltage information If Marvel requires the return of original parts we will inform you when the parts order is taken This requirement will be no...

Страница 17: ...er and part description Some parts will require color or voltage information Marvel requires the return of original parts we will inform you when the parts order is taken This requirement will be note...

Страница 18: ...Of PROPERTY IN ACCORDANCE WITH FEDERAL OR LOCAL REGULATIONS FLAHHABLE REFRIGERANT USED R 600A Specifications Gloves and Eye Protection must be used R 600a is considered non toxic but is flammable when...

Страница 19: ...ended that a simple LPG gas detector is on site during service Ensure that all R 600a is removed from the system prior to brazing any part of the sealed system Only a clean dry leak free system should...

Страница 20: ...uate and charge with dry nitrogen for leak checks Repair leaks or replace system parts as required R 600A Specifications When re brazing the system must be purged with dry nitrogen and at least one ac...

Страница 21: ...microns prior to charging Weigh in the R 600a charge using a refrigerant scale run compressor an extra two minutes to clear the charging hoses Seal the Schrader Type access port a proper cap and seal...

Страница 22: ...um temperature temperature cool cool No Gas 0 PSIG to 25 Room Cool to hot temperature cool System Diagnosis Guide Condenser Capillary Evaporator Wattage Tube Very hot Warm Cold Normal Hot to warm Cool...

Страница 23: ...are not hot or frozen Do not touch a bare circuit board unless you are wearing an anti static wrist strap that is grounded to an electrical ground or grounded water pipe Handle circuit boards carefull...

Страница 24: ...nvironment When in this mode the only functions will be the control and cabinet lights The compressor fans etc will not operate To enter exit this mode hold the light key and the power key for 5 secon...

Страница 25: ...nce accident or improper use maintenance instal lation service repair acts of God fire flood or other natural disasters The product must be installed operated and maintained in accordance with the Mar...