Marvel MLVB224 Скачать руководство пользователя страница 12

ENERGY SAVING TIPS

4.  Plug your appliance into a dedicated power circuit. (Not 

shared with other appliances).

5.  When initially loading your new product, or whenever 

large quantities of warm contents are placed within 

refrigerated storage compartment, minimize door 

openings for the next 12 hours to allow contents to pull 

down to compartment set temperature.

6.  Maintaining a relatively full storage compartment will 

require less appliance run time than an empty compart-

ment.

7.  Ensure door closing is not obstructed by contents 

stored in your appliance.

8.  Allow hot items to reach room temperature before plac-

ing in product.

9.  Minimize door openings and duration of door openings.

10. Use the warmest temperature control set temperature 

that meets your personal preference and provides the 

proper storage for your stored contents.

11. When on vacation or away from home for extended pe-

      riods, set the appliance to warmest acceptable tem-

      perature for the stored contents.

12. Set the control to the “off” position if cleaning the 

      appliance requires the door to be open for an extended

      period of time.

13. For wine storage products:

               When serving temperatures are not required, 

               return the compartment(s) set temperature to the

               ideal red and white wine long term storage tem-

               perature of 13°C / 55°F.

The following suggestions will minimize the 

cost of operating your refrigeration appliance.

1. 

Do not install your appliance next to a hot appliance 

(cooker, dishwasher, etc.), heating air duct, or other 

heat sources.

2.  Install product out of direct sunlight.

3.  Ensure the front grille vents at front of appliance be-

neath door are not obstructed and kept clean to allow 

ventilation for the refrigeration system to expel heat.

12

Содержание MLVB224

Страница 1: ...OWNERS GUIDE MARVEL OUTDOOR UNDERCOUNTER REFRIGERATION T H E O R I G I N A L R E F R I G E R A T I O N E X P E R T S S I N C E 1 8 9 2 F O R M O D E L M O R F 2 2 4...

Страница 2: ...w home Send us photos at marketing marvelrefrigera tion com and we might feature your Marvel home design on our website and social media XXXXXXXXXXXX XXXXXXXXXXXX MARVEL g Figure 1 R600A WELCOME It is...

Страница 3: ...pliance Electrical Installing The Water Supply Maintenance Care and Cleaning Stainless Steel Maintenance Operating Instructions Ice Maker Operation Interior Adjustments Energy Savng Tips Service Obtai...

Страница 4: ...em free installation and operation WARNING WARNING You can be killed or seriously injured if you do not follow these instructions WARNING State of California Proposition 65 Warning This product contai...

Страница 5: ...lace The owners manual is shipped inside the product in a plastic bag along with the warranty registration card and other accessory items Important Keep your carton and packaging until your appliance...

Страница 6: ...rrupters GFCI are prone to nui sance tripping which will cause the appliance to shut down GFCI s are generally not used on circuits with power equip ment that must run unattended for long periods of t...

Страница 7: ...gth and coil it behind the unit to form a service loop which will allow the appliance to be pulled out from the installation for servicing or cleaning Connect the copper tubing to the top side of a co...

Страница 8: ...aise the ice maker bail arm 3 Empty the ice bucket 4 Replace the ice bucket in the unit and lower the bail arm Dispensing of the cubes should occur within 2 hours After the ice cubes dispense empty cl...

Страница 9: ...ng the shelf To Add or Remove a Shelf Remove stored product from the shelf Do not try to remove a loaded shelf from the appliance Grasp the shelf front with both hands rotate the install a shelf inser...

Страница 10: ...cuit Not shared with other appliances 5 When initially loading your new product or whenever large quantities of warm contents are placed within refrigerated storage compartment minimize door openings...

Страница 11: ...upon the installation location environmental and usage conditions Choosing a Cleaning Product The choice of a proper cleaning product is ultimately that of the consumer and there are many products fro...

Страница 12: ...rsonal preference and provides the proper storage for your stored contents 11 When on vacation or away from home for extended pe riods set the appliance to warmest acceptable tem perature for the stor...

Страница 13: ...rt section In all correspondence regarding service be sure to give the service number serial number and proof of purchase Try to have information or description of nature of the problem how long the a...

Страница 14: ...r and part description Some parts will require color or voltage information If Marvel requires the return of original parts we will inform you when the parts order is taken This requirement will be no...

Страница 15: ...er and part description Some parts will require color or voltage information Marvel requires the return of original parts we will inform you when the parts order is taken This requirement will be note...

Страница 16: ...Of PROPERTY IN ACCORDANCE WITH FEDERAL OR LOCAL REGULATIONS FLAHHABLE REFRIGERANT USED R 600A Specifications Gloves and Eye Protection must be used R 600a is considered non toxic but is flammable when...

Страница 17: ...ended that a simple LPG gas detector is on site during service Ensure that all R 600a is removed from the system prior to brazing any part of the sealed system Only a clean dry leak free system should...

Страница 18: ...uate and charge with dry nitrogen for leak checks Repair leaks or replace system parts as required R 600A Specifications When re brazing the system must be purged with dry nitrogen and at least one ac...

Страница 19: ...microns prior to charging Weigh in the R 600a charge using a refrigerant scale run compressor an extra two minutes to clear the charging hoses Seal the Schrader Type access port a proper cap and seal...

Страница 20: ...um temperature temperature cool cool No Gas 0 PSIG to 25 Room Cool to hot temperature cool System Diagnosis Guide Condenser Capillary Evaporator Wattage Tube Very hot Warm Cold Normal Hot to warm Cool...

Страница 21: ...nvironment When in this mode the only functions will be the control and cabinet lights The compressor fans etc will not operate To enter exit this mode hold the light key and the power key for 5 secon...

Страница 22: ...nce accident or improper use maintenance instal lation service repair acts of God fire flood or other natural disasters The product must be installed operated and maintained in accordance with the Mar...

Страница 23: ...DQJH ZLWKRXW QRWLFH 6XFK UHYLVLRQV GR QRW HQWLWOH the buyer to corresponding changes improvements additions replacements or compensation for previously purchased products www marvelrefrigeration com 1...

Отзывы: