DOOR ADJUSTMENTS
NOTE
!
CAUTION
T-25 Torx Screw
T-25 Torx Screw
Figure 2
8
Door Adjustments - MLNP115
& MPNP415
DOOR ALIGNMENT AND ADJUSTMENT
Align and adjust the door if it is not level or not sealing
properly. If the door is not sealed, the unit may not cool
properly, or excessive frost or condensation may form in
the interior.
Properly aligned, the door’s gasket should be firmly in
contact with the cabinet all the way around the door (no
gaps). Carefully examine the door’s gasket to ensure
that it is firmly in contact with the cabinet. Also make
sure the door gasket is not pinched on the hinge side of
the door.
Do not attempt to use the door to raise or pivot your unit.
This would put excessive stress on the hinge system.
Alignment and Adjustment Procedure
1. Open door and remove gasket near the hinges.
2. Using a T-25 Torx bit, loosen each pair of Torx head
screws both the upper and lower hinge plates.
3. Square and align door as necessary.
4. Tighten Torx head screws on hinge.
5. Reinstall gasket into the channel starting at the
corner.