Thermistors 

Thermistors are used for various temperature readings. 
Thermistors provide reliable temperature readings 
using a resistance which varies based on  surrounding 
temperatures.  If a faulty thermistor  is suspected it may be 
tested using an accurate ohmmeter. 

Both  thermistors  in the unit are  identical.  If a thermistor 

is suspected of being defective,  the resistance can be 
verified.  Place the thermistor in an ice water bath,  the 
resistance should read  16.lk  Ohms  +/-5% on your meter. 

Thermistor connections must be kept  clean.  A thermistor 
connection that has become corroded can  cause resistance 
values from the thermistor to change as they pass through 
a dirty connection to the board. 

It is for that reason that we apply dielectric grease to all of 

our thermistor connections.  Dielectric grease will help to 
keep thermistor connections clean and dry. 

If you change a  thermistor  in  the unit please re-apply 

dielectric grease to the connection.  If you encounter 
a dirty thermistor connection,  you should replace the 
thermistor and the thermistor harness. 

Thermistor error  information can be found in  the Control 

Operations -  Service  section. 

This unit has 

two 

thermistors. 

Thermistor one  (Zone): 

Located along the right hand side wall.  It  is used to 

maintain the operating temperature within that  zone. 

Thermistor two  (Evaporator): 

Located on the evaporator.  It is used for  defrost. 

THERMISTOR  FAILURE 

Zone Thermistor 

If the zone thermistor in the unit fails,  the unit will 

continue to cool in a backup mode (Self  Preservation 

Mode)  to preserve the integrity of the contents. The unit 

will otherwise operate normally. 

Thermistor 

Evaporator Thermistor 

If the evaporator thermistor fails,  the unit will rely  on a 

preset defrost timer during defrost cycles. The unit will 
otherwise operate normally.  Refer  to defrost section. 

Thermistor  Resistance  Data 

Temp  (F) 

Temp  (C) 

Nominal  Resistance 

(OHMS)* 

-40

-40

169157 

-31

-35

121795 

-22

-30

88766 

-13

-25

65333 

-4

-20

48614 

-15

36503 

14 

-10

27681 

23 

-5

21166 

32 

16330 

41 

12696 

50 

10 

9951 

59 

15 

7855 

68 

20 

6246 

77 

25 

5000 

86 

30 

4029 

95 

35 

3266 

104 

40 

2665 

113 

45 

2186 

122 

50 

1803 

131 

55 

1495 

140 

60 

1247 

149 

65 

1044 

158 

70 

879 

167 

75 

743 

176 

80 

631 

*(+/-5%) 

23

Содержание MLFZ224

Страница 1: ...OWNERS GUIDE MARVEL UNDERCOUNTER REFRIGERATION T H E O R I G I N A L R E F R I G E R A T I O N E X P E R T S S I N C E 1 8 9 2 F O R M O D E L M L F Z 2 2 4...

Страница 2: ...lem free installation and operation WARNING WARNING You can be killed or seriously injured if you do not follow these instructions WARNING State of California Proposition 65 Warning This product conta...

Страница 3: ...ectrical Installing the anti tip device Integrated Panel Dimensions Integrated Panel Installation Maintenance Care and Cleaning Extended Non Use Operating Instructions Energy Savng Tips Service Obtain...

Страница 4: ...lace The owners manual is shipped inside the product in a plastic bag along with the warranty registration card and other accessory items Important Keep your carton and packaging until your appliance...

Страница 5: ...rrupters GFCI are prone to nui sance tripping which will cause the appliance to shut down GFCI s are generally not used on circuits with power equip ment that must run unattended for long periods of t...

Страница 6: ...ith the end of the 211 2 54 6 cm line Rear of cabinet line 5 Fasten the anti tip bracket to the floor using the supplied screw See Figure 15 6 Slide the cabinet back into position making sure the rear...

Страница 7: ...nti tip bracket is used the mini mum adjusted height of the cabinet is increased by 3 8 9 mm Figure 15a V notches in bracket V notches in bracket Figure 15 211 2 54 6 cm Front of cabinet line Rear Lev...

Страница 8: ...uct is pressed against the adjacent cabinet use a 5 8 thick panel The window cutout is for glass door models only Do not use a solid door panel on a glass door model INTEGRATED PANEL DIMENSIONS Top of...

Страница 9: ...ket retainer extrusions 3 on each side and 2 at the top and bottom which are used to fasten the panel to the front of the door The screws are provided in the literature pack Step 3 Assemble the Panel...

Страница 10: ...or swing reinstall hinges per Door Reversal Instructions Carefully slide lower hinge bushing over bottom hinge pin Install the new upper hinge bushing into adaptor plate Align hinge bushing with top h...

Страница 11: ...cuit Not shared with other appliances 5 When initially loading your new product or whenever large quantities of warm contents are placed within refrigerated storage compartment minimize door openings...

Страница 12: ...rsonal preference and provides the proper storage for your stored contents 11 When on vacation or away from home for extended pe riods set the appliance to warmest acceptable tem perature for the stor...

Страница 13: ...low ice to thaw naturally 4 Clean and dry the interior of the unit Ensure all water has been removed from the unit 5 The door must remain open to prevent formation of mold and mildew Open door a minim...

Страница 14: ...rt section In all correspondence regarding service be sure to give the service number serial number and proof of purchase Try to have information or description of nature of the problem how long the a...

Страница 15: ...r and part description Some parts will require color or voltage information If Marvel requires the return of original parts we will inform you when the parts order is taken This requirement will be no...

Страница 16: ...er and part description Some parts will require color or voltage information Marvel requires the return of original parts we will inform you when the parts order is taken This requirement will be note...

Страница 17: ...Of PROPERTY IN ACCORDANCE WITH FEDERAL OR LOCAL REGULATIONS FLAHHABLE REFRIGERANT USED R 600A Specifications Gloves and Eye Protection must be used R 600a is considered non toxic but is flammable when...

Страница 18: ...ended that a simple LPG gas detector is on site during service Ensure that all R 600a is removed from the system prior to brazing any part of the sealed system Only a clean dry leak free system should...

Страница 19: ...uate and charge with dry nitrogen for leak checks Repair leaks or replace system parts as required R 600A Specifications When re brazing the system must be purged with dry nitrogen and at least one ac...

Страница 20: ...microns prior to charging Weigh in the R 600a charge using a refrigerant scale run compressor an extra two minutes to clear the charging hoses Seal the Schrader Type access port a proper cap and seal...

Страница 21: ...um temperature temperature cool cool No Gas 0 PSIG to 25 Room Cool to hot temperature cool System Diagnosis Guide Condenser Capillary Evaporator Wattage Tube Very hot Warm Cold Normal Hot to warm Cool...

Страница 22: ...nvironment When in this mode the only functions will be the control and cabinet lights The compressor fans etc will not operate To enter exit this mode hold the light key and the power key for 5 secon...

Страница 23: ...connection you should replace the thermistor and the thermistor harness Thermistor error information can be found in the Control Operations Service section This unit has two thermistors Thermistor one...

Страница 24: ...nce accident or improper use maintenance instal lation service repair acts of God fire flood or other natural disasters The product must be installed operated and maintained in accordance with the Mar...

Отзывы: