Marvel ML-150-12 Скачать руководство пользователя страница 4

1.2

 

Safety Instructions 

For safety reasons, installers are responsible for familiarizing themselves with the contents of this document 
and all warnings before performing installation.

 

1.2.1

 

General Safety Precautions 

Over-voltages or wrong wiring can damage the battery pack and cause deflagration, which can be extremely 
dangerous. 
All types of breakdown of the product may lead to a leakage of electrolyte or flammable gas. 
Avoid installing the battery pack where flammable materials are stored. Do not install in places where 
explosive gas or chemicals are present. 
The utility grid, solar input, and battery voltage must be disconnected from the Battery Pack wiring. Wiring 
must be carried out by a qualified person. 
Battery Pack is not user serviceable. 

1.2.2

 

Battery Handling guide 

Do not expose battery to open flame. 
Do not place the product nearby flammables. It may lead to fire or explosion in case of accident. 
Do not expose or place near water sources like downspouts or sprinklers. 
Do not store this product in a place exposed to direct sunlight. 
A ventilated area is strongly recommended for handling the product. 
Store at cool and dry place. (Do not store in greenhouses and storage areas for hay, straw, chaff, animal 
feed, fertilizers, vegetables or fruit products.) 
Store the product on a flat surface. 
Store the product out of reach of children and animals. 
Store the product where it should be minimal dust and dirt in the area. 
Do not disconnect, disassemble or repair by unquali

ed personnel. Service must be made by quali

ed 

personnel only. 
Do not damage the unit in such ways as dropping, deforming, impacting, cutting or penetrating with a sharp 
object. It may cause a leakage of electrolyte or 

re. 

Do not touch if liquid is spilled on the product. There is a risk of electric shock. Handle the battery wearing 
the insulated gloves. 
Do not step on the product or the product package. The product may be damaged. 
Do not place any foreign objects on the top of the Battery Pack. 
Do not put the battery pack upside down on the ground. 
Do not connect anode and cathode terminal block opposite direction. 
Do not charge or discharge damaged battery. 
If the battery pack is installed in the garage then ensure the product is above the height of the vehicle 
bumper. 
The battery pack only be installed indoors. If installed outdoors, do not allow the battery pack to be exposed 
to direct sunlight and water source as it may cause: 
-Power limitation phenomena in the battery 
(with a resulting decreased energy production by the system) 
-Premature wear of the electrical/electromechanical components and mechanical components. 
-Reduction in performance, service life and possible damage of the battery 
Only use the product with supplier recommend inverter and solar charge controller 

MPPT

Do not connect any AC conductors or Photo-voltaic conductors directly to the battery pack and should be 
only connected to the Inverter and solar charge controller 

MPPT

.

Содержание ML-150-12

Страница 1: ...xplain system configuration concepts and installation instructions Please note the image shown is for illustration purposes only Warning Read this entire document before installing or using this produ...

Страница 2: ...n 10 3 1Install Location 10 3 2Tools Safety Gears Required 10 3 2 1Tools 10 3 2 2Safety Gears For Personal Protection 10 3 3DC Cable Prepared 11 3 3 1Choose DC Cable 11 3 3 2Fabrication of DC Cable 11...

Страница 3: ...t of reach of children Read the instruction manual before starting installation and operation Heavy weight may cause serious injury to the back Do not dispose of the product with household wastes Recy...

Страница 4: ...he product where it should be minimal dust and dirt in the area Do not disconnect disassemble or repair by unquali ed personnel Service must be made by quali ed personnel only Do not damage the unit i...

Страница 5: ...eries if it is safe to do so power off the switch If the battery pack is not on fire yet extinguish the fire before the battery pack catches fire If the battery pack is on fire do not try to extinguis...

Страница 6: ...ltage and temperature it also makes a good communication between battery system and the host equipment Monitoring unit will automatically measure the battery charge and discharge current charge and di...

Страница 7: ...5 2 3 Appernce and Mechanical Drawing ML 150 12 ML 200 12 ML 200 24...

Страница 8: ...6 ML100 51 2 ML 200 48...

Страница 9: ...120A 100A 120A 15 Max Discharge Current RT 120A 5S 120A 5S 130A 8S 130A 8S 130A 8S 16 Over Discharge Protection Release Charging or Cut off loads and Restart 17 Discharge Temp Range 10 55 RT 25 Cycle...

Страница 10: ...w Main Interface Maximum and minimum cell voltage maximum and minimum cell temperature Press the menu key of main interface to enter the above interface Select the item and press the menu key to enter...

Страница 11: ...oading and unloading process should be light moving gently to prevent throwing rolling pressing Direct rain and mechanical impact of rain and snow should be avoided in transportation 2 5 2 Storage Pro...

Страница 12: ...ldren and animals CAUTION If the ambient temperature is outside of the operating range the battery pack may stop operating to protect the internal components The optimal temperature range for the batt...

Страница 13: ...or more information WARNING The torque rating range for DC terminal is 9NM 12NM and the suggested torque rating is 9NM Over torqueing may cause the bolt to break 3 3 2 Fabrication of DC Cable You can...

Страница 14: ...The pressure shall be maintained for 2 seconds during crimping Step4 Install the riveted terminal into the plug body Step5 Install the upper cover of the plug into the plug body Step6 Install the she...

Страница 15: ...S AND OR STRAPS TO HANDLE THE WEIGHT OF THE BATTERY WELL VENTILATED HEAVY DUTY BATTERY CABINET IS RECOMMENDED 3 4 1 Battery Installation Wall Mounted Battery Installation Step1 Use an M8 drill bit wit...

Страница 16: ...tion Step1 Use M8 drill bit with drilling depth of about 40mm and drill the corresponding hole position according to the following battery installation dimensions Step2 Move the battery to the corresp...

Страница 17: ...ls note the distance of batteries Vertical Battery Parallel Installation Tips Hole drilling installation shall be carried out according to the installation method of single battery in Chapter 3 4 1 Pl...

Страница 18: ...r part is connected normally Step 2 Check whether the communication harness is connected normally as required Step 3 Setting a corresponding communication protocol between and battery and inverter Ple...

Страница 19: ...rotocol V1 13 1 PYLON CAN Bus protocol PYLON low voltage V1 2 20180408 1 PYLON PYLON low voltage protocol RS485 V3 5 20200227 2 Growat Growatt Bms CAN BUS protocol low voltage v1 08 2 Growat SPF RS485...

Страница 20: ...ol click Enter to automatically jump to the third number At the time the third number is in flashing state and enters the CAN protocol selection state The selection range is 15 bits 0 D Select corresp...

Страница 21: ...step according to the mode shown in the figure below NOTE Both Master and RS485 ports can connect with PC and other parallel batteries The Master RS485 communicate to PC need to buy USB to 485 tool Ma...

Страница 22: ...ter software Master port One RS485 interface is used for external inverter communication and this port can also be used as the CAN communication port CAN RS485 port 4 4 1 Master RS485 CAN Ports Introd...

Страница 23: ...x03 3 ON ON OFF OFF 4 0x04 4 OFF OFF ON OFF 5 0x05 5 ON OFF ON OFF 6 0x06 6 OFF ON ON OFF 7 0x07 7 ON ON ON OFF 8 0x08 8 OFF OFF OFF ON 9 0x09 9 ON OFF OFF ON 10 0x0A 10 OFF ON OFF ON 11 0x0B 11 ON ON...

Страница 24: ...y non technician System design and installation are not in compliance with standards and regulations Failure to comply with the local safety regulations Transport damage including painting scratch cau...

Отзывы: