18
(Adjust oil flow to the right range)
An abrupt stop during operation
1.
Couplers are not connected
2.
Damage of control valve
1.
Check each connected parts
2.
Replace a control valve *
Oil leakage from control lever
1. Damage, wear or harden of O ring
1. Replace O ring *
Profuse Oil leakage from front end
1.
Damage of U cup packing
2.
Damage of U cup packing due to the
scratch of piston rod.
1.
Replace U cup packing *
2.
Replace U cup packing, remove the
scratch on piston rod *
Latch is nearly coming off
1. Damage of lock spring
2. Ware of latch
1. Replace lock spring *
2. Replace latch *
High pressure hose shakes intensely
1. Damage of accumulator diaphragm
1. Replace diaphragm *
Release the control valve but the breaker
does not stop
1. Foreign substance is caught in the
valve rod
1. Disassemble, clean and adjust *
For items with *, ask Maruzen dealers for service and maintenance.