Display   

Function   

Remaining backup time information 

 

Indicates the remaining backup time in pie chart. 

 

Indicates the remaining backup time in numbers. 

H: hours, M: minute, S: second 

Fault information 

 

Indicates that the warning and fault occurs. 

 

Indicates the warning and fault codes, and the codes are listed in 
details in 3-5 section. 

Mute operation   

 

Indicates that the UPS alarm is disabled.   

Output & Battery voltage information   

 

Indicates the output voltage, frequency or battery voltage. 

Vac: output voltage, Vdc: battery voltage, Hz: frequency 

Load information   

 

Indicates the load level by 0-25%, 26-50%, 51-75%, and 76-100%.   

 

Indicates overload. 

 

Indicates the load or the UPS output is short circuit. 

Mode operation information 

 

Indicates the UPS connects to the mains. 

 

Indicates the battery is working.   

 

Indicates the bypass circuit is working. 

 

Indicates the ECO mode is enabled. 

 

Indicates the Inverter circuit is working. 

 

Indicates the output is working. 

Battery information 

 

Indicates the Battery level by 0-25%, 26-50%, 51-75%, and 
76-100%. 

 

Indicates the battery is fault. 

 

Indicates low battery level and low battery voltage. 

Input & Battery voltage information 

 

Indicates the input voltage or frequency or battery voltage. 

Vac: Input voltage, Vdc: battery voltage, Hz: input frequency 

Содержание ULT-3K

Страница 1: ...ale Avenue City of Industry California 91748 U S A Tel 1 626 912 8388 Fax 1 626 912 8680 Toll Free 1 888 MARUSON E Mail Info MarusonUSA com Website www MarusonUSA com All trademarks are the property o...

Страница 2: ...s 2 2 Installation and setup 3 2 1 Rear panel view 3 2 2 Setup the UPS 5 3 Operations 7 3 1 Button operation 7 3 2 LCD Panel 7 3 3 Audible Alarm 9 3 4 LCD display wordings index 9 3 5 UPS Setting 10 3...

Страница 3: ...er them Do not connect domestic appliances such as hair dryers to UPS output sockets The UPS can be operated by any individuals with no previous experience Connect the UPS system only to an earthed sh...

Страница 4: ...must be kept well away from the batteries Caution risk of electric shock The battery circuit is not isolated from the input voltage Hazardous voltages may occur between the battery terminals and the...

Страница 5: ...thing inside the package is damaged Please keep the original package in a safe place for future use 2 1 Rear panel view 1K India Type IEC Type NEMA Type Schuko Type Universal Type 1KL India Type IEC T...

Страница 6: ...ersal Type 3KL India Type IEC Type Schuko Type Universal Type 1 AC input 2 Input circuit breaker 3 USB communication port 4 RS 232 communication port 5 SNMP intelligent slot option 6 External battery...

Страница 7: ...for 2K model Step 3 UPS output connection For socket type outputs simply connect devices to the outlets For terminal type input or outputs please follow below steps for the wiring configuration a Remo...

Страница 8: ...the ON Mute button on the front panel for two seconds to power on the UPS Note The battery charges fully during the first five hours of normal operation Do not expect full battery run capability duri...

Страница 9: ...in standby mode under power normal or transfer to Bypass mode if the Bypass enable setting by pressing this button Confirm selection key Press this button to confirm selection in UPS setting mode Sele...

Страница 10: ...frequency Load information Indicates the load level by 0 25 26 50 51 75 and 76 100 Indicates overload Indicates the load or the UPS output is short circuit Mode operation information Indicates the UPS...

Страница 11: ...twice every second Fault Continuously sounding Bypass Mode Sounding every 10 seconds 3 4 LCD display wordings index Abbreviation Display content Meaning ENA Enable DIS Disable ESC Escape HLS High loss...

Страница 12: ...voltage 100 presents output voltage is 100Vac 110 presents output voltage is 110Vac 115 presents output voltage is 115Vac 120 presents output voltage is 120Vac Default 127 presents output voltage is 1...

Страница 13: ...the nominal voltage Default 12V For 100 110 115 120 127 VAC models the setting voltage in parameter 3 is from 3V to 12V of the nominal voltage Default 6V 06 Bypass enable disable when UPS is off Inte...

Страница 14: ...mitation setting Interface Setting Parameter 3 Set up backup time on battery mode for general outlets 0 999 setting the backup time in minutes from 0 999 for general outlets on battery mode 0 When set...

Страница 15: ...er mode When input frequency is within 40 Hz to 70 Hz the UPS can be set at a constant output frequency 50 Hz or 60 Hz The UPS will still charge battery under this mode Battery mode When the input vol...

Страница 16: ...ltage high 12 x Charger failure 45 x Inverter voltage Low 13 x 3 8 Warning indicator Warning Icon flashing Alarm Low Battery Sounding every second Overload Sounding twice every second Battery is not c...

Страница 17: ...e every second UPS is overload Remove excess loads from UPS output UPS is overloaded Devices connected to the UPS are fed directly by the electrical network via the Bypass Remove excess loads from UPS...

Страница 18: ...up time is shorter than nominal value Batteries are not fully charged Charge the batteries for at least 5 hours and then check capacity If the problem still persists consult your dealer Batteries defe...

Страница 19: ...ler Storage Before storing charge the UPS 5 hours Store the UPS covered and upright in a cool dry location During storage recharge the battery in accordance with the following table Storage Temperatur...

Страница 20: ...t Ratio 3 1 Harmonic Distortion 3 THD linear load 6 THD non linear load Transfer Time AC Mode to Batt Mode Zero Inverter to Bypass 4 ms Typical Waveform Batt Mode Pure Sinewave EFFICIENCY AC Mode 88 8...

Отзывы: