This UPS utilizes voltage that may be hazardous. Do not attempt to
disassemble the unit. The unit contains no user replaceable parts.
Only factory service personnel may perform repairs.
This pluggable type A equipment with battery already installed by
the supplier is operator installable and may be operated by laymen.
The mains socket outlet that supplies the UPS shall be installed
near the UPS and shall be easily accessible.
During the installation of this equipment it should be assured that
the sum of the leakage currents of the UPS and the connected
loads does not exceed 3.5mA.
Unplug the UPS prior to cleaning and do not use liquid or spray
detergent.
Connection to any other type of receptacle other than a two-pole,
three-wire grounded receptacle may result in shock hazard as well
as violate local electrical codes.
In the event of an emergency, press the "OFF" button and
disconnect the power cord from the AC power supply to properly
disable the UPS.
Do not allow any liquids or any foreign object to enter the UPS. Do
not place beverages or any other liquid-containing vessels on or
near the unit.
This unit intended for installation in a controlled environment
(temperature controlled, indoor area free of conductive
contaminants). Avoid installing the UPS in locations where there is
standing or running water, or excessive humidity.
Do not plug the UPS input into its own output.
Do not attach a power strip or surge suppressor to the UPS.
Do not attach non-computer-related items, such as medical
equipment, life-support equipment, microwave ovens, or vacuum
cleaners to UPS.
To reduce the risk of overheating the UPS, do not cover the UPS'
cooling vents and avoid exposing the unit to direct sunlight or
installing the unit near heat emitting appliances such as space
heater or furnaces.
MODEL
POW-1100A(S)
POW-1600AS
POW-2200AS
CAPACITY
1100VA/600W
1600VA/900W
2200VA/1200W
OUTLET
NUMBER
NEMA(120V)
6
8
8
IEC(230V)
4
6
6
INPUT
Voltage
110/115/120VAC or 220/230/240 VAC
Voltage
Range
81-145VAC or 162-290 VAC
Frequency
50/60 Hz (auto sensing)
OUTPUT
Voltage
110/115/120VAC or 220/230/240 VAC
Frequency
Regulation
(Batt. Mode)
60 Hz or 50 Hz ± 1 Hz
Waveform
Simulated Sine Wave
BATTERY
Battery Type
& Numbers
12V/7Ahx2
12V/9Ahx2
12V/9Ahx2
Backup Time
Up to 60 min.
Up to 85 min.
Up to 90 min.
PROTECTION
Full
Protection
Discharge, overcharge, and overload protection
PHYSICAL
Dimension
(DxWxH)
320 x 130 x 182 (mm)
12.6 x 5.1 x 7.2 (inch)
Net Weight
8.2 kgs
18.1 lbs
10.4 kgs
22.9 lbs
10.6 kgs
23.4 lbs
Do not dispose of batteries in a fire as they may explode.
A battery can present a risk of electrical shock and high short circuit
current. The following precautions should be observed when
working on batteries:
1) Remove watches, rings, or other metal objects from the hands.
2) Use tools with insulated handles.
3) Wear rubber gloves and boots.
4) Do not lay tools or metal parts on top of batteries.
5) Disconnect charging source prior to connecting or disconnecting
batteries terminal.
Internal battery voltage is 12VDC.Sealed, lead-acid, 6-cell battery.
Servicing of batteries should be performed or supervised by
personnel knowledgeable of batteries and the required precautions.
Keep unauthorized personnel away from batteries.
When replacing batteries, replace with the same number and type
of sealed lead-acid battery.
Do not open or mutilate the battery or batteries. Released
electrolyte is harmful to the skin and eyes and may be toxic.
Attention, hazardous through electric shock. Also with
disconnection of this unit from the mains, hazardous voltage may
still be accessible through supply from battery. The battery supply
should be therefore disconnected in the plus and minus pole at the
connectors of the battery when maintenance or service work inside
the UPS is necessary.
Battery Recycling Information
Your UPS contains non-spillable Sealed Lead Battery. On the battery,
you will find the battery name. Please reference below chart for
recycling information or contact your local distributor for assistance.
Battery Name
Recycling inside the USA
Recycling outside the USA
RITAR Battery
(800) 273-8599
N/A
Problem
Probable Cause
Solution
No LED display
on the front
panel.
Low battery.
Charge the battery at least 8
hours.
Battery fault.
Replace the battery with
the same type of battery.
The UPS is not
turned on.
Press the power switch
again to turn on the UPS.
Alarm continuously
sounds when the
mains is normal.
The UPS is overloaded.
Remove some loads first.
Before reconnecting
equipment, please verify
that the load matches the
UPS capability specified in
the specs.
When power fails,
backup time is
shorten.
The UPS is overloaded.
Remove some critical load.
Battery voltage is too
low.
Charge the battery at least
8 hours.
Battery defect. It
might be due to high
temperature operation
environment, or
improper operation
to battery.
Replace the battery with
the same type of battery.
The mains is normal
but LED is flashing.
Power cord is loose.
Reconnect the power cord
properly.
If any abnormal situations occur that are not listed above, please call
for service immediately.
Product Warranty and Service Information:
For U.S. customers, please register your product at www.MarusonUSA.com.
For international customers, please contact your local authorized distributor or
e-mail [email protected] for assistance.
Maruson Technology Corporation
1351 Titan Way, Brea, CA 92821, USA
P.O. Box 1986, Walnut, CA 91788, USA
Toll Free: 1-888-MARUSON
TEL: +1-714-870-6888
FAX: +1-714-870-4888
E-mail:[email protected]
Web Site: www.MarusonUSA.com
Safety Caution
SAVE THESE INSTRUCTION-This manual contains important instructions for models
Power UPS 1100/1600/2200 that should be followed during installation and maintenance of the UPS and batteries.
Panel Information
Specification
*Specifications are subject to change without notice.
*Battery backup time based on basic PC and varies with equipment, configuration,
battery age, temperature, etc
Troubleshooting