background image

2

Avoid severe mechanical shock or vibration and extreme temperature.

To avoid possible corrosion from leaking batteries, remove the batteries if discharged, or when the 
unit is not in use for an extended period.

2. INTRODUCTION

2.1 Inspection

Examine the shipping carton for any sign of damage. Inspect the unit and any accessories for 
damage. If there is any damage then consult your distributor immediately.

2.2 Description

The DTL84 has the following functions and features:

‹

  Four channel inputs

‹

  Selectable thermocouple type (K, J, E, T, N, R, S)

‹

 Differential 

temperature 

measurement

‹

 Temperature 

alarm 

function

‹

  Fast response and sampling rate

‹

  Instant recall function

‹

  Adjustable auto power off

‹

   Bluetooth connection to PC or mobile device

‹

  iOS & Android APP available to download from APP store

‹

  USB PC interface with Windows software included.

2.3 Accessories

 The DTL84 comes with the following accessories:

‹

  2 x K-type thermocouples

‹

 Bluetooth 

adaptor

‹

  4 x 1.5V AAA LR03 batteries

‹

  DTL84 software CD

‹

  Micro USB cable 

‹

 Storage 

case 

‹

 Instructions

2.4 Battery Installation  

Refer to Section 6.1 (Battery Replacement). 

2.5 Bluetooth Adaptor Installation

Refer to Section 6.2 (Bluetooth Adaptor Installation).

3

3. OPERATION 

3.1 Description of Press Buttons and DTL84 Elements

1

Thermocouple input sockets

2

LCD display

3

Turns the DTL84 on/off

4

Turns the backlight on/off

5

W

MIN

MAX
AVG

 

Selects max, min or average readings

6

W

 

HOLD

Selects the data hold function

7

°

°

F

W

Selects the temperature scale

8

REC

W

Starts/stops the record function

9

RECALL

Recalls saved readings

10

SET

Enters/exits Set-up function

11

MEM

W

Saves readings to the memory

12

USB interface

13

Bluetooth adaptor

14

Bluetooth adaptor compartment

15

Tilt stand

16

Battery compartment

4

3.2 Description of LCD symbols

 

Indicates low battery

MIN

Minimum recorded value is displayed

MAX

Maximum recorded value is displayed

AVG

Average reading is displayed

SET

Setup option indicator

Auto power off is active

REC

Indicates recording is active

FULL

Memory full indicator

MEM

88

Indicates memory location of stored data

RECALL

88

Indicates memory location when recalling stored data

TYPE

 

KJET

Indicates selected thermocouple type

T1 T2 T3 T4

Temperature channel

T1-T2

T1-T2 differential temperature mode selected

ALARM

Indicates temperature alarm selected

Hi

Indicates high temperature alarm tripped 

Lo

Indicates low temperature alarm tripped

OFFSET

Probe error compensation

°

C

°

Indicates temperature scale

HOLD

Display hold mode is active

n

N-type thermocouple is selected

r

R-type thermocouple is selected

S

S-type thermocouple is selected

Bluetooth pairing/standby

Bluetooth connected

3.3 Low Battery Indication  

If the 

 symbol is displayed, the battery needs replacing as measurement accuracy can no 

longer be guaranteed (See section 6.1 Battery Replacement).

5

3.4 Power On/Off

Press 

 to power on the meter. Press and hold 

 for 3 seconds to power off.

3.5 Backlight

Press 

 to turn on the display backlight. Press 

 again to turn off the backlight.  

It will automatically turn off after 30 seconds if there is no further operation of the meter. 

3.6 Data Hold 

To hold displayed readings, press 

W

 

HOLD

 The HOLD symbol will be displayed.

Press again to exit the Data-Hold mode. 

Note: 

When Data-Hold mode is selected the 

W

MIN

MAX
AVG

 

°

°

F

W

 

RECALL

 

SET

 

buttons are disabled.

3.7 Record Function

Measurement data recorded at set time intervals can be saved to the internal memory. Refer to 4.4 
(Setting Data Recording Interval Time) to set the required time interval.

Press 

REC

W

 to start recording data. The 

REC

 symbol will be displayed.

To stop recording, press 

REC

W

 again. 

The recorded data can be downloaded to a PC using the DTL84 software.

Note: 

‹

   During recording, the 

°

°

F

W

 and 

SET

 buttons are disabled so any required settings need to be 

selected before starting the data logger function.

‹

   When the memory is full (32,000 results), the "

FULL

" symbol will flash on the LCD. The data 

logger function will stop.

‹

   When the battery power is low, the 

 symbol appears on the screen and the data logger 

function will not start. If the battery is running low during data logging, it will stop recording 
automatically.

3.8 Memory Function

Press 

MEM

W

 to save the current displayed temperature readings to memory. The 

MEM

 symbol and 

the number of the memory location will appear on the screen for 2 seconds. 

Press 

MEM

W

 again to store further sets of results. 

The memory has 0-99 locations. 

3.9 Recalling Saved Results

Press 

RECALL

 to recall saved results. The 

RECALL

 

symbol and the number of the last used memory 

location will be displayed. 

The time the data was save will be displayed in hours, mins, secs for 2 seconds before the saved 
temperature readings are displayed.

Press the arrow keys 

W

 

HOLD

 

REC

W

 

W

MIN

MAX
AVG

 

°

°

F

W

 t

o select the required memory location. 

Press 

RECALL

 or 

 to exit RECALL mode. 

Отзывы: