background image

SPECIFICATIONS

General

Captured Conductor Size: 30mm maximum.

Low Battery Indicator: Red LED lighting.

Operating Temperature: 0° C to 50° C, Max 70% R.H.

Storage Temperature: -20° C to +70° C, Max 80% R.H.

Weight: 290gm typical

Dimensions: 178mm (H) x 70mm (W) x 33mm (D).

Electrical 

Accuracy (At 23°  ±  5° C, 70% R.H maximum)

DC Current: 0 to 600A, ±  (2% r 2A)

AC current: 50Hz to 400Hz

0 to 400A, ±  (2% r 2A)

400A to 500A, ±  (3% r 2A)

500A to 600A, ±  (6% r 2A)

Load Resistance: 10K Typical.

Output: 0 to 600mV (AC and DC) for 0 to 600A.

Met

Metrohm House, Imperial Park, Imperial Way, Watford, Hertfordshire, WD24 4PP, UK 

Tel: 01923 441717  Fax: 01923 446900.

Due to policy of continuous development, Martindale reserves the right to alter equipment specification and description

 

outlined in this document without prior notice. No part of this document shall be deemed to be part of any contract for the

 

equipment unless specifically referred to as an inclusion within such contract.            

©

 

Martindale Electric Co. Ltd. 2000

CT60

AC/DC Current

Clamp

INSTRUCTION MANUAL

Отзывы: