5. WARRANTY AND LIMITATION OF LIABILITY

This Martindale product is warranted to be free from defects in material 

and workmanship under normal use and service. The warranty period 

is 2 years and begins on the date of receipt by the end user. This 

warranty extends only to the original buyer or end-user customer, 

and does not apply to fuses, disposable batteries, test leads or to any 

product which, in Martindale’s reasonable opinion, has been misused, 

altered, neglected, contaminated, or damaged by accident or abnormal 

conditions of operation, handling or storage.  

Martindale authorised resellers shall extend this warranty on new and 

unused products to end-user customers only but have no authority to 

extend a greater or different warranty on behalf of Martindale.

Martindale’s warranty obligation is limited, at Martindale’s option, to refund 

of the purchase price, free of charge repair, or replacement of a defective 

product which is returned to Martindale within the warranty period.

This warranty is the buyer’s sole and exclusive remedy and is in lieu 

of all other warranties, expressed or implied, including but not limited 

to any implied warranty of merchantability or fitness for a particular 

purpose. Martindale shall not be liable for any special, indirect, incidental 

or consequential damages or losses, including loss of data, arising from 

any cause or theory.

Since some jurisdictions do not allow limitation of the term of an implied 

warranty, or exclusion or limitation of incidental or consequential 

damages, the limitations and exclusions of this warranty may not apply 

to every buyer. If any part of any provision of this warranty is held invalid 

or unenforceable by a court or other decision-maker of competent 

CM79 instruct rev1.indd   16

23/11/2015   11:01:01

16

jurisdiction, such holding will not affect the validity or enforceability of 

any other provision or other part of that provision.

Nothing in this statement reduces your statutory rights.

CM79 instruct rev1.indd   13

23/11/2015   11:01:01

17

CM79 instruct rev1.indd   12

23/11/2015   11:01:00

Specification
CM79
TRMS AC/DC Clamp Meter

ELECTRICAL

All specified accuracies are at 23°C ± 5°C, <80% RH for 1 year.

Temperature coefficient:  

Add 0.1 x (specified accuracy) per °C. (0°C to 18°C, 

28°C to 40°C).

Accuracies below are expressed as ± (percentage of r digits)

DC Voltage

Range

Resolution

Input 

impedance

Accuracy

600V

0.1V

1M

:

1.0% + 2

Overload protection: 660V DC or AC rms

AC Voltage 

(True RMS)

Range

Resolution

Input 

impedance

Accuracy

(50 to 500Hz)

600V

0.1 V

1M

:

1.2% + 5

Overload protection: 660V DC or AC rms

CM79 instruct rev1.indd   9

23/11/2015   11:00:59

Содержание CM79

Страница 1: ...tructions and product information are available at www martindale electric co uk 1 1 Meaning of Symbols and Markings Caution risk of danger refer to instructions Caution risk of electric shock Equipment protected by double or reinforced insulation Class II Application around and removal from hazardous live conductors is permitted CAT II Measurement Category II is applicable to test and measuring e...

Страница 2: ...ngers behind the clamp safety protection barrier When making current measurements using the clamps disconnect the test leads from the clamp meter terminals Cautions Avoid severe mechanical shock or vibration and extreme temperature When using test leads avoid excessive stresses to the cable entry points at the probe and 4mm plug connector To avoid possible corrosion from leaking batteries remove t...

Страница 3: ...function press for 2 seconds 8 3 11 Use of the TL16 Test Leads Before use always check the continuity of the test leads Where access to test points may require extended probe tips the probe tip caps may be removed by gently pulling them forward until they unclip from the probe body CAT III 1000V CAT IV 600V CAT II 1000V ONLY DO NOT USE ON CAT III or CAT IV installations 3 12 AC Current Measurement...

Страница 4: ...ar to an approved Calibration Laboratory for recalibration and certification Martindale Electric is pleased to offer you this service Please contact our Service Department for details Email service martindale electric co uk Tel 01923 650660 4 4 Cleaning To reduce the risk of surface leakage this instrument must be kept in a clean condition Prior to cleaning ensure that the instrument is disconnect...

Страница 5: ...erchantability or fitness for a particular purpose Martindale shall not be liable for any special indirect incidental or consequential damages or losses including loss of data arising from any cause or theory Since some jurisdictions do not allow limitation of the term of an implied warranty or exclusion or limitation of incidental or consequential damages the limitations and exclusions of this wa...

Страница 6: ... 2 032 CAT III 600V Class II double insulation EMC Conforms to BS EN 61326 1 Specification CM79 TRMS AC DC Clamp Meter SPECIFICATION FOR TL16 TEST LEADS Maximum voltage 1000V AC DC Maximum current 10A continuous Connector 4mm banana plug with fixed shroud Environmental Temperature Operating Storage 0 C to 40 C Altitude up to 2000m Pollution degree 2 Safety Conforms to BS EN 61010 031 CAT IV 600V C...

Отзывы: