background image

 

   

RUSH™ Scanner 1 LED User Manual 

41 

Construction 

Color ......................................................................................................... Black 
Housing ......................................... High-impact flame-retardant thermoplastic 
Protection rating ....................................................................................... IP 20 

Installation 

Mounting points ............................. Adjustable bracket, surface or truss mount 
Location .................. Indoor use only, must be fastened to surface or structure 
Orientation ...................................................................................................Any 

Connections 

AC power input .................................................................... Neutrik PowerCon 
AC power throughput .......................................................... Neutrik PowerCon 
DMX data in/out ........................................................ 3-pin  &  5-pin locking XLR 

Electrical 

AC power ............................................................ 100-240 V nominal, 50/60 Hz 
Power consumption ................................................................................  168  W 
Typical half-cycle RMS inrush current at 240 VAC ................................... 10 A 
Fuse ...................................................................................................... T 6.3 A 
Power supply unit ................................... Auto-ranging electronic switch mode 

Typical power and current 

100 V, 60 Hz ................................................................ 1.7 A, 170 W, PF 0.997 
120 V, 60 Hz ................................................................ 1.4 A, 165 W, PF 0.994 
230 V, 50 Hz ................................................................ 0.7 A, 162 W, PF 0.937 

Figures obtained at nominal voltage. Figures are typical, not maximum, allow 
for +/- 10% variation 

Thermal  

Cooling ............................................................................................. Forced air 
Maximum ambient temperature (T

a

 max.) .................................. 40° C (104° F) 

Minimum ambient temperature (T

a

 min) .......................................... 0°C (32° F) 

Total heat dissipation ................................................................... 570 BTU/hr.* 

*Calculated, +/- 10%, at full intensity 

Approvals 

  

     

   

 

EU safety ....................... EN 60598-2-17 (EN 60598-1), EN 62471, EN 62493  
EU EMC ................................................ EN 55015, EN 55103-1, EN 55103-2, 
 

EN 61000-3-2, EN 61000-3-3, EN 61547 

US safety ............................................................................................. UL 1573 
US EMC .......................................................................... FCC Part 15 Class B 

Содержание RUSH Scanner 1 LED

Страница 1: ...RUSH Scanner 1 LED User Manual...

Страница 2: ...oss occasioned by the use of inability to use or reliance on the information contained in this manual Martin Harman and all other trademarks in this document pertaining to services or products by Mart...

Страница 3: ...16 Control data link 18 Tips for reliable data transmission 18 Connecting the DMX data link 18 Fixture setup 20 Using the control menus 20 DMX settings 20 Effects settings 23 Calibration settings 24 S...

Страница 4: ...d Warning Risk Group 2 product according to EN 62471 Do not look directly into the beam Do not view the light output with optical instruments or any device that may concentrate the beam This lighting...

Страница 5: ...installation or maintenance work and when the fixture is not in use Ensure that the fixture is electrically connected to ground earth Use only a source of AC power that complies with local building a...

Страница 6: ...suit the application In the USA and Canada the cables must be UL listed type SJT or equivalent In the EU the cables must be type H05VV F or equivalent Suitable cables with Neutrik PowerCon connectors...

Страница 7: ...ertain control menu items are selected To minimize the risk of eye irritation or injury disconnect the fixture from power at all times when the fixture is not in use and provide well lit conditions to...

Страница 8: ...ith missing or damaged covers shields or any optical component Block access below the work area and work from a stable platform whenever installing servicing or moving the fixture In the event of an o...

Страница 9: ...mounting brackets Before using the product for the first time 1 Read Safety information on page 4 before installing powering operating or servicing the fixture 2 Unpack and ensure that there is no tra...

Страница 10: ...t In standalone operation the display shows the number of the selected standalone show 3 Buttons MENU Press to activate the menu Within the menu press to escape and return to the previous level Press...

Страница 11: ...ated scene changes in show mode 8 9 10 11 DMX input output sockets For your convenience both 3 pin and 5 pin XLR sockets are provided for DMX input and output throughput Connect suitable DMX data cabl...

Страница 12: ...you install the fixture in a location where it may cause injury or damage if it falls secure it as directed in this user manual using a securely anchored safety cable that will hold the fixture if the...

Страница 13: ...the clamp when installed In all other installations use a half coupler clamp see illustration on right To clamp the fixture to a truss 1 Check that the rigging structure can support at least 10 times...

Страница 14: ...14 RUSH Scanner 1 LED User Manual Rigging with short and long brackets...

Страница 15: ...e that the surface and all fasteners used can support at least 10 times the weight of all fixtures and equipment they will support Fasten the fixture securely Do not stand it on a surface or leave it...

Страница 16: ...the fixture and easily accessible so that the fixtures can easily be disconnected from power Do not insert or remove live Neutrik PowerCon connectors to apply or cut power as this may cause arcing at...

Страница 17: ...n see Accessories on page 42 you can relay mains power from one fixture to another by connecting fixtures to power in a linked daisy chain MAINS OUT throughput socket to MAINS IN input socket Using 14...

Страница 18: ...e designed for RS 485 devices standard microphone cable cannot transmit control data reliably over long runs 24 AWG cable is suitable for runs up to 300 meters 1000 ft Heavier gauge cable and or an am...

Страница 19: ...utput from the controller to the first fixture s male 3 pin or 5 pin XLR DMX input connector 2 Connect the first fixture s DMX output to the DMX input of the next fixture and continue connecting fixtu...

Страница 20: ...ing a change press MENU To exit the control menus completely press and hold MENU DMX settings DMX address The RUSH Scanner 1 LED uses 16 DMX channels The DMX address also known as the start channel is...

Страница 21: ...Mode Nine pre programmed standalone shows are available To set the show that the fixture will run in Show Mode 1 Select SHOW MODE and press ENTER 2 Use the DOWN and UP buttons to select a show from 0...

Страница 22: ...h the Master fixture When sound activation is running the SOUND status LED on the control panel flashes in sync with the music beat To set sound activation 1 Select SOUND MODE and press ENTER to confi...

Страница 23: ...o be linear as DMX value is increased MODE 2 SQUARE LAW light intensity control is finer at low levels and coarser at high levels MODE 3 INVERSE SQUARE LAW light intensity control is coarser at low le...

Страница 24: ...ion 1 Power the fixture on if matching multiple fixtures aim them so that their projections are side by side 2 Select DIMMER CALIBRATE and press ENTER 3 Using the DOWN and UP buttons change the value...

Страница 25: ...lumination can be turned on or off To adjust the backlight settings 1 Select BACK LIGHT menu and press ENTER 2 Select ON to illuminate the display or OFF for a dark display 3 Press ENTER to confirm yo...

Страница 26: ...ixed gobos Gobo wheel 1 shown from front lens side Images will be flipped left right when projected Individual gobos on wheel 1 can be rotated clockwise and counter clockwise and a gobo shake function...

Страница 27: ...ture incorporates a prism than can be inserted into the beam providing split effects The prism can be set to an indexed position or rotated clockwise or counter clockwise Strobe effects The strobe eff...

Страница 28: ...nadequate cleaning or maintenance is not covered by the product warranty The cleaning of external optical lenses must be carried out periodically to optimize light output Cleaning schedules for lighti...

Страница 29: ...the surface hard lift particles off with a soft repeated press Dry with a soft clean lint free cloth or low pressure compressed air Remove stuck particles with an unscented tissue or cotton swab mois...

Страница 30: ...us scrolling 0 White 1 14 White Red 15 Red Color 1 16 29 Red Deep Blue 30 Deep Blue Color 2 31 44 Deep Blue Lavender 45 Lavender Color 3 46 59 Lavender Magenta 60 Magenta Color 4 61 74 Magenta Yellow...

Страница 31: ...us scrolling 0 White 1 14 White Pink 15 Pink Color 1 16 29 Pink CTO 3200K 30 CTO 3200K Color 2 31 44 CTO 3200K UV Purple 45 UV Purple Color 3 46 59 UV Purple Light Yellow 60 Light Yellow Color 4 61 74...

Страница 32: ...Gobo wheel 1 rotating gobos Gobo selection 0 4 Open 5 9 Gobo 1 10 14 Gobo 2 15 19 Gobo 3 20 24 Gobo 4 25 29 Gobo 5 30 34 Gobo 6 Gobo rotation set direction and speed on channel 7 35 39 Gobo 1 40 44 Go...

Страница 33: ...fixed gobos Continuous scrolling 0 Open 1 14 Open Gobo1 15 Gobo 1 16 29 Gobo 1 Gobo 2 30 Gobo 2 31 44 Gobo 2 Gobo 3 45 Gobo 3 46 59 Gobo 3 Gobo 4 60 Gobo 4 61 74 Gobo 4 Gobo 5 75 Gobo 5 76 89 Gobo 5 G...

Страница 34: ...ockwise rotation fast slow 127 129 Stop 130 253 Counter clockwise rotation slow fast 254 255 Stop 11 0 255 Focus infinity near 12 0 255 Pan 0 170 13 0 255 Pan fine control 14 0 255 Tilt 0 75 15 0 255...

Страница 35: ...ntrol panel display 165 194 No function 195 199 Store color wheel 1 calibration 200 204 Store color wheel 2 calibration 205 209 Store gobo wheel 1 wheel calibration 210 214 Store gobo wheel 1 gobo cal...

Страница 36: ...ion music trig Off No sound activation Sound Sense 0 100 Microphone sensitivity for sound activation DMX State Show Mode If DMX signal stops fixture enters show mode Blackout If DMX signal stops fixtu...

Страница 37: ...ttings No Reset Reset fixture Offset adjustment The Offset menu is used to adjust the home position of the various effects To access the Offset menu 1 Press the MENU button to enter the menu structure...

Страница 38: ...e Check all power connections and cables Replace the fixture fuse The fixture does not react to the beat of music Sound activation disabled Sound activation sensitivity too low for music source Ensure...

Страница 39: ...all DMX cables and connections to ensure the integrity of the physical link Ensure that the DMX link is terminated Check that all devices on the DMX link use standard DMX polarity Ensure that the fix...

Страница 40: ...zed Electronic dimming 0 100 four dimming curve options Pan 170 coarse fine control Tilt 75 coarse fine control Control and Programming Control options DMX standalone synchronized master slave DMX cha...

Страница 41: ...f cycle RMS inrush current at 240 VAC 10 A Fuse T 6 3 A Power supply unit Auto ranging electronic switch mode Typical power and current 100 V 60 Hz 1 7 A 170 W PF 0 997 120 V 60 Hz 1 4 A 165 W PF 0 99...

Страница 42: ...erCon connectors 2 25 m 7 4 ft P N 11541510 Power relay cable 14 AWG SJT 1 5 mm2 H05VV F with PowerCon connectors 3 25 m 10 7 ft P N 11541511 Power connectors Neutrik PowerCon NAC3FCA power input conn...

Страница 43: ...where applicable Help preserve the environment Ensure that this product is recycled at the end of its life Your supplier can give details of local arrangements for the disposal of Martin products Phot...

Страница 44: ......

Страница 45: ......

Страница 46: ......

Страница 47: ......

Страница 48: ...www martin com Olof Palmes All 18 8200 Aarhus N Denmark Tel 45 8740 0000 Fax 45 8740 0010...

Отзывы: