6
I
NSTALLATION
3
The RoboColor Pro 400 package includes mounting bracket and fittings, 3-pin XLR
data cable, mains cable, and this users guide. The fixture is adjusted at the factory so
that only a few basic procedures are necessary before the fixture is ready for use.
Warning!
Disconnect the unit from AC power before proceeding.
Important! Verify that the voltage and frequency settings match your power
supply before connecting to power.
INSTALL LAMP
The Philips MSD 200 is the only lamp approved for use in the RoboColor Pro 400.
1 Remove the 3 thumbscrews that secure the access plate of the lamp socket
assembly at the rear of the RoboColor and withdraw the lamp socket assembly.
2 Hold the Philips MSD 200 lamp (not included) in a clean cloth to avoid
contaminating the glass bulb and carefully insert it into the socket. Clean the
lamp with the alcohol wipe packaged with the lamp.
3 Replace the lamp socket assembly and tighten the thumbscrews.
See also the lamp alignment procedure on page 13.
INSTALL MOUNTING BRACKET
The bracket allows you to turn or tilt the RoboColor to the desired position.
1 On each side of the RoboColor is a stud for the mounting bracket. Fit a plastic
washer, a star washer, and then the mounting bracket onto these studs.
2 Lock the mounting bracket using the two lever handles.
CONNECT TO POWER
If there is no plug on the mains cable, you must install one that fits your mains
outlet before connecting the fixture to power.
•
Connect the brown wire to the LIVE pin, connect the blue wire to the NEUTRAL
pin and connect the yellow/green wire to the EARTH pin (ground).
User.fm Page 6 Monday, April 17, 2000 11:22 AM