Martin MPL PENINSULA Скачать руководство пользователя страница 29

28

53D9042. Rev 1 03/03

L

IMITED

  W

ARRANTY

FACTORY-BUILT FIREPLACE AND COMPONENTS

(

EXCEPT

 

BLOWERS

)

W

HAT

 

IS

 

COVERED

 

AND

 

FOR

 

HOW

 

LONG

• F

IVE

-Y

EAR

 C

OVERAGE

 - For five years from the date this fireplace and components are first purchased for use,  Martin

Hearth & Heating will, at its option, repair or replace any defective part of this fireplace or components, or refund to you
a sum not to exceed the factory retail price in effect at the time of purchase.

• T

EN

-Y

EAR

  C

OVERAGE

  - From the sixth through the tenth year following the date this fireplace or accessory is first

purchased for use, Martin Hearth & Heating will make available to you, at our factory, a free replacement for any
defective part in this fireplace or accessory.

• T

WENTY

-F

IVE

-Y

EAR

 A

VAILABILITY

 

OF

 R

EPLACEMENT

 P

ARTS

 - From the eleventh through the twenty-fifty year following the date

this fireplace or accessory is first purchased for use, Martin Hearth & Heating will make available at our factory
replacement parts for this fireplace or accessory, which you may purchase for the list price current at the time your
purchase order is received.

W

HAT

 I

S

 N

OT

 C

OVERED

This limited warranty does not cover:

• Transportation or shipping cost.
• The cost of a service call to diagnose trouble.
• Painted surfaces.
• Damage or defect caused by improper installation, accident, misuse, abuse or alteration.
• Poor ventilation of smoke or gases caused by air-conditioning and heating systems, exhaust fans, or pressure

differentials produced by wind.

• Broken glass components
• Cracks in ceramic and castable parts that do not affect safe operation.
• We do not warrant this fireplace to be in compliance with your local building code.  Building codes vary greatly

throughout the country, and you should determine whether your local building code contains restrictions on the use
of this fireplace before you purchase it.

• Blowers or fans, which are warranted separately.
• Heat loss due to the passage of heat or air through or around the fireplace.

Also, under our five year coverage, we do not pay the cost of removal and replacement of any portion of the structure in
which the fireplace is situated, made necessary by the repair, removal or re-installation of the fireplace.

And under our twenty-five year warranty of availability of replacement parts, we only promise to maintain a supply of
replacement parts at our factory for you to purchase.

L

IMITATIONS

 

AND

 E

XCLUSIONS

1.

No one has authority to add to or vary this limited warranty, or to create for Martin Hearth & Heating any other
obligation of liability in connection with this fireplace and accessory.

2.

Martin Hearth & Heating 

SHALL

 

NOT

 

BE

 

LIABLE

 

FOR

 

INCIDENTAL

CONSEQUENTIAL

SPECIAL

 

OR

 

CONTINGENT

 

DAMAGES

 

YOU

 

MIGHT

SUFFER

 

AS

 

A

 

RESULT

 

OF

 

ITS

 

BREACH

 

OF

 

THIS

 

WRITTEN

 

WARRANTY

 

OR

 

ANY

 

IMPLIED

 

WARRANTY

.  Some states do not allow the exclusion

of limitation of incidental or consequential damages, so the above limitations may not apply to you.

3.

This warranty applies only to the original purchaser of the fireplace or to the original owner of the dwelling when the
fireplace is installed in a new dwelling and may not be transferred.

5.

This warranty applies only to a fireplace sold and used in the United States.

Содержание MPL PENINSULA

Страница 1: ...ON OPERATION AND MAINTENANCE MANUAL THIS FIREPLACE IS LISTED BY OMNI TEST LABORATORIES FOR USE WITH L SERIES CHIMNEY SYSTEM COMPONENTS 53D9042 Rev 1 03 03 GLASS DOORS ARE REQUIRED ON THIS MODEL FIREPL...

Страница 2: ...er factory built fireplace properly can result in a house fire or other occurrences that could cause deaths injuries and property damages It is very important that the persons installing and or superv...

Страница 3: ...as INTENDED PRODUCT USAGE The fireplace is designed to sit directly on a combustible floor The fireplace must be installed with clearances to combustible building materials specified in this manual On...

Страница 4: ...ped with doors should be operated only with the doors fully open or doors fully closed If doors are left partly open gas and flame may be drawn out of the fireplace opening creating risks of both fire...

Страница 5: ...6 4 CLEARANCES 53D9042 Rev 1 03 03...

Страница 6: ...nterfere with chimney performance and cause the fireplace to spill smoke into the room Since the pitch of the roof influences the opening size required at the roof level table 1 should be used as a gu...

Страница 7: ...CLEARANCES 6 53D9042 Rev 1 03 03...

Страница 8: ...ng chimney cap For use with flat chase top terminations 612 0 6 12 pitch flashing for contemporary installation 1212 6 12 12 12 pitch flashing for contemporary installation LF FS 2 17 inch firestop sp...

Страница 9: ...f the fireplace To help prevent the crack from developing the hearth extension materials must be firmly fastened in place Wall ties should be screwed to the face of the fireplace and imbedded in the m...

Страница 10: ...operly install the chimney This is an important part of the installation and the sections of this manual pertaining to chimney installation should be reviewed very thoroughly For your safety some of t...

Страница 11: ...CHIMNEY INSTALLATION 10 53D9042 Rev 1 03 03...

Страница 12: ...11 53D9042 Rev 1 03 03 CHIMNEY INSTALLATION...

Страница 13: ...tly to a building frame member or ceiling joist as shown by Figure 13 You must use at least two 8 penney nails per strap ELBOW INSTALLATION The following are important points that should be observed w...

Страница 14: ...13 53D9042 Rev 1 03 03 CHIMNEY INSTALLATION...

Страница 15: ...CHIMNEY INSTALLATION 14 53D9042 Rev 1 03 03...

Страница 16: ...NTERMEDIATE SECTIONS 4 0 0 1 0 1 1 0 1 1 0 2 1 0 2 1 0 2 1 3 2 1 3 2 1 3 2 4 3 2 4 3 2 4 3 5 4 3 5 4 3 5 4 6 5 4 6 5 4 6 5 7 6 5 7 6 5 7 6 8 3 1 0 0 1 0 0 2 0 1 2 0 1 3 0 2 3 1 2 0 1 3 0 2 3 1 2 0 1 3...

Страница 17: ...under the shingles 3 Set the flashing on the roof Hold a section of the outside pipe 13 diameter on the flashing and scribe a line around the flashing then cut the top off the flashing by cutting 1 4...

Страница 18: ...should be soldered together to form two watertight seams 3 Place the outer telescope inside the hole in the chase cover and lower it down into the mating pipe of the chimney until the support bracket...

Страница 19: ...r will not be connected 2 Place the insulation ring between the AK 4 starting collar and fireplace wall and place the starting collar 4 inch into the hole on the side of the fireplace Fasten it in pla...

Страница 20: ...ENDATIONS NOTE The use of outside air for combustion is optional unless required by building codes It is only necessary to supply outside combustion air to one side of the fireplace Use the model AK4...

Страница 21: ...n Unions must be of the ground joint type 4 Some code authorities prohibit or place restrictions on the use of gas appliances in fireplaces Check with local code authorities before proceeding with the...

Страница 22: ...hing the base to the supporting floor will further reduce the possibility of such a crack developing Wall ties should be fastened to the face of the fireplace with sheet metal screws and placed in the...

Страница 23: ...MPL NO PART NAME QTY PART NO 1 Panel Front Ptd Assy 4 042988 2 Panel End Ptd Assy 1 042990 3 Panel End Vented Ptd Assy 1 043006 4 Post Corner Ptd Assy 4 043008 5 Cap Corner Post 2 043009 6 Flange Nail...

Страница 24: ...tle combined with other wood goes a long way Start your fire with a mixture of softwood and hardwood then add some fruit or nut wood for nostalgic aroma Since most woods will not burn well when freshl...

Страница 25: ...e is equipped with glass doors close them DO NOT LEAVE CHILDREN OR PHYSICALLY OR MENTALLY HANDICAPPED OR SENILE PERSONSALONE WITH A BURNING FIREPLACE You ll need a minimum of three logs preferably fou...

Страница 26: ...to determine if a creosote buildup has occurred If creosote has accumulated it should be removed to reduce the risk of a chimney fire The chimney cap can be removed for inspection maintenance and cle...

Страница 27: ...s for the installation of the fireplace 4 Do insulate the exterior walls surrounding the fireplace to prevent excessive heat loss from the fireplace 5 Do trim the face of the fireplace only with nonco...

Страница 28: ...lace flammable liquids gases or pressurized containers near the fireplace 16 Don t neglect to instruct all responsible persons in the proper and safe operation of the fireplace 17 Don t fail to instru...

Страница 29: ...onents Cracks in ceramic and castable parts that do not affect safe operation We do not warrant this fireplace to be in compliance with your local building code Building codes vary greatly throughout...

Страница 30: ...Contact the nearest dealer If you cannot locate your dealer call or write Martin Hearth Heating as indicated below 2 If you do not receive satisfactory service from the dealer within a reasonable time...

Страница 31: ...30 53D9042 Rev 1 03 03 NOTES...

Страница 32: ...ATTENTION APPLIANCE INSTALLER PLEASE RETURN THESE OPERATING AND INSTALLATION INSTRUCTIONS TO THE CONSUMER 53D9042 REV 1 03 03...

Отзывы: