Service and display messages
29
FAN
HD M FAN ERR
Head mid cooling fan has stopped running. Lamp is shut down. Error cleared when fixture is
reset.
FBEP
PAN FBACK ERR
Pan position magnetic indexing system timeout. Fixture is unable to correct pan position (but
pan movement will often still be possible).
FBET
TILT FBACK ERR
Tilt position magnetic indexing system timeout. Fixture is unable to correct tilt position (but tilt
movement will often still be possible).
FOER
FOCUS ERROR
Focus position electrical indexing system timeout.
IRER
IRIS ERROR
Iris position electrical indexing system timeout.
LAER
LAMP ERROR
The lamp is defective, has exploded, is missing, or the lamp cannot restrike after eight attempts.
Pan and tilt are locked. DMX control is disabled. Fixture reset command in control menus is
disabled.
MAER
MAGENTA ERROR
Magenta position electrical indexing system timeout.
PAER
PAN ERROR
Pan position electrical indexing system timeout.
PSER
PAN SENSOR ERROR
Fixture unable to retrieve reliable data from pan position sensor.
PTCM
P/T SENSOR CAL
Pan/tilt sensors are not calibrated.
PTTC
PT TEMP CUT OFF
Pan/tilt PCB temperature too high. Thermal cutoff activated. Lamp is shut down, fans set to max.
Error cleared when fixture is reset.
PUTC
PSU TEMP CUT OFF
PSU temperature too high. Thermal cutoff activated. Lamp is shut down, fans set to max. Error
cleared when fixture is reset.
SHUE
SHUTTER ERROR
Shutter position electrical indexing circuit timeout.
SLER
SAFETY LOOP
Lamp safety loop circuit activated. Lamp temperature circuit breaker has cut lamp power. Circuit
breaker resets automatically after lamp temperature has returned to normal operating range.
SSTO
SYSSTATE TIMEOUT
Some part of the system did not startup as expected. This error message is usually followed by
other more descriptive messages. Service intervention required. Fixture control possibly
disabled, depending on nature of error.
TIER
TILT ERROR
Tilt position electrical indexing circuit timeout.
TSER
TILT SENSOR ERR
Fixture unable to retrieve reliable data from tilt position sensor.
UECM
UPL ERR CMY
Could not upload new firmware to the color mixing system. Error cleared when new firmware is
uploaded successfully or power is cycled off and on.
UEEF
UPL ERR EFFECT
Could not upload new firmware to the projection system. Error cleared when new firmware is
uploaded successfully or power is cycled off and on.
UEPT
UPL ERR PAN/TILT
Could not upload new firmware to the pan/tilt system. Error cleared when new firmware is
uploaded successfully or power is cycled off and on.
UEUI
UPL ERR UI
Could not upload new firmware to the user interface system.
UEZF
UPL ERR Z/F
Could not upload new firmware to the zoom/focus system.
UITC
UI TEMP CUT OFF
User interface PCB temperature too high. Thermal cutoff activated. Lamp is shut down, fans set
to max. Error cleared when fixture is reset.
Short code
Long message and explanation
Table 4: Error messages