Martin MAC Viper AirFX Скачать руководство пользователя страница 13

Service and maintenance

 13

Service and maintenance

Warning! Read “Safety Information” on page 4 before servicing the MAC Viper AirFX.

Warning! Disconnect the fixture from AC mains power and allow to cool for at least 30 minutes 
minutes before handling. Do not stare into the light output. Be prepared for the fixture to light and 
move suddenly when connected to power.

Warning! The MAC Viper AirFX™ contains components that are accessible and live at high voltage 
while the fixture is connected to power and that remain under tension for 30 minutes after power is 
disconnected. Only technicians who are authorized by Martin™ and who have access to the 
Martin™ service documentation for the MAC Viper AirFX are permitted to open the base and yoke of 
the fixture. The user may open the MAC Viper AirFX’s head only to carry out the service operations 
described in this section, following the warnings and instructions provided. Refer any service 
operation not described in this manual or the product’s User Guide to a qualified service technician.

Important! Excessive dust, smoke fluid, and particle buildup degrades performance, causes 
overheating and will damage the fixture. Damage caused by inadequate cleaning or maintenance is 
not covered by the product warranty.

The user will need to clean the MAC Viper AirFX periodically, The user may also replace gobos, color filters, 
the iris, the FX wheel and air filters in the head and update the firmware. All other service operations on the 
MAC Viper AirFX must be carried out by Martin Professional™, its approved service agents or trained and 
qualified personnel using the official Martin™ service documentation for the MAC Viper AirFX.

Installation, on-site service and maintenance can be provided worldwide by the Martin Professional Global 
Service organization and its approved agents, giving owners access to Martin’s expertise and product 
knowledge in a partnership that will ensure the highest level of performance throughout the product’s 
lifetime. Please contact your Martin supplier for details.

It is Martin policy to apply the strictest possible calibration procedures and use the best quality materials 
available to ensure optimum performance and the longest possible component lifetimes. However, optical 
components are subject to wear and tear over the life of the product, resulting in gradual changes in color 
over many thousands of hours of use. The extent of wear and tear depends heavily on operating conditions 
and environment, so it is impossible to specify precisely whether and to what extent performance will be 
affected. However, you may eventually need to replace optical components if their characteristics are 
affected by wear and tear after an extended period of use and if you require fixtures to perform within very 
precise optical and color parameters.

Tilt lock

The tilt position of the head can be locked at 45° for service. See Figure 1 on page 6. Push the lock in 
towards the yoke in one direction to lock the head and back in from the other side to unlock the head.

Important!

Release the tilt lock before applying power to the fixture and before packing the fixture in its 
flightcase.

Lamp

The MAC Viper AirFX is designed for use with a highly efficient 1000 watt short-arc Osram HTI 1000/PS 
Lok-it discharge lamp. This lamp has a color temperature of 6000 K, a color rendering index greater than 85 
and an average service life of 750 hours. Do not use any lamp that is not approved by Martin™ for the MAC 
Viper AirFX.

Warning!

Installing a lamp that is not approved may create a safety hazard or damage the fixture!

Lamp power is automatically reduced to approximately 800 W after 10 seconds when the dimmer/shutter is 
closed in order to reduce cooling fan activity and power consumption. The lamp returns to 1000 W as soon 
as the dimmer/shutter is opened.

Содержание MAC Viper AirFX

Страница 1: ...MAC Viper AirFX SAFETY AND INSTALLATION MANUAL...

Страница 2: ...anies disclaim liability for any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contain...

Страница 3: ...Power input 10 DMX data link 12 Service and maintenance 13 Tilt lock 13 Lamp 13 Lubrication 16 Access to the head 16 Cleaning 16 Replacing the head air filters 17 Access to projection effects 19 Repla...

Страница 4: ...use only It is not for household use This product presents risks of severe injury or death due to fire and burn hazards electric shock lamp explosion and falls Refer to Martin Service or an authorized...

Страница 5: ...bustible materials e g fabric wood paper at least 0 3 m 12 in away from the fixture Keep flammable materials well away from the fixture Provide a minimum clearance of 0 1 m 4 in around fans and air ve...

Страница 6: ...ackaged in either a cardboard box or a flightcase that is designed to protect the product during shipment The following items are included Osram HTI 1000 PS Lok it discharge lamp installed 2 omega bra...

Страница 7: ...e than with the yoke hanging vertically downwards use two clamps of half coupler type Do not use any type of clamp that does not completely encircle the structure when fastened Warning Position or sha...

Страница 8: ...f the base The arrow indicates the front of the fixture 4 Align the first clamp and bracket with 2 mounting points in the base See Figure 5 Insert the clamp bracket s fasteners into the base and turn...

Страница 9: ...Check that the tilt lock is released Check that there are no combustible materials within 0 3 m 12 in or surfaces to be illuminated within 3 4 m 11 2 ft of the fixture and that there are no flammable...

Страница 10: ...PowerCon input connector without a cable see Accessories on page 29 Installing a power input connector on a power cable To install a Neutrik PowerCon NAC3FCA input connector on a power cable see illu...

Страница 11: ...mains power on off switch B is set to O Off before inserting or removing the power input connector at the input socket A otherwise you may cause arcing at connector terminals that can damage them Shu...

Страница 12: ...t Heavier gauge cable and or an amplifier is recommended for longer runs To split the data link into branches use one of the splitter amplifiers available from Martin see under Accessories in the prod...

Страница 13: ...oved agents giving owners access to Martin s expertise and product knowledge in a partnership that will ensure the highest level of performance throughout the product s lifetime Please contact your Ma...

Страница 14: ...not touch it with your fingers Clean the lamp with an alcohol wipe and polish it with a clean dry lint free cloth before installing particularly if you accidentally touch the bulb To replace the lamp...

Страница 15: ...e sure that the lamp is correctly adjusted at all times A significant hot spot in the beam will focus extra heat onto optical components and may cause damage that is not covered by the product warrant...

Страница 16: ...To reinstall the head covers 1 See Figure 12 Hold each cover up to the head and fasten its safety wire retaining clip B into the head chassis by pressing the clip through its hole and then sliding it...

Страница 17: ...used but residues must be removed with distilled water Clean with a slow circular motion from center to edge Dry with a clean soft lint free cloth or low pressure compressed air Remove stuck particles...

Страница 18: ...snap into the housing and that the cover is located correctly with no gaps where air could bypass the filter 9 Reconnect the air filter fan connector B 10 Hook the rear end of the air filter housing i...

Страница 19: ...ad facing upwards and apply the tilt lock see Access to the head on page 16 3 See Figure 15 The projection module is closest to the front of the fixture Release its two Torx 20 retaining screws arrowe...

Страница 20: ...in parts Handle and store components with care Wear cotton gloves while handling them and keep them perfectly clean to reduce the risk of heat damage Gobos general The MAC Viper AirFX uses specially d...

Страница 21: ...t the gobo with the matted coating facing towards the front of the fixture away from the lamp Coated Glass Gobos The heavy matted aluminum coated borosilicate gobos in the MAC Viper AirFX are factory...

Страница 22: ...one at a time To replace a gobo 1 See Figure 20 Turn the aerial effect wheel so that the magnets arrowed in each goboholder all point in towards the center of the wheel 2 Grasp the goboholder by its t...

Страница 23: ...e gobo 8 See Figure 23 Push the goboholder back into its clip so that the jaws of the clip engage in the groove around the goboholder and the magnet arrowed points in towards the center of the gobo wh...

Страница 24: ...on clean cotton gloves and hold the filter near its outer edge between finger and thumb Pull the outer edge of the filter up from the color wheel slightly to release it then slide the filter carefully...

Страница 25: ...flat headed screwdriver to lever the retaining circlip A away from the static gobo wheel hub B to release the wheel Avoid bending the wheel during removal and storage 5 To install a static gobo wheel...

Страница 26: ...rol and display panel RDM Remote Device Management compatibility Software service functions Applying power Warning Before applying power to the fixture Carefully review the safety information starting...

Страница 27: ...rect addressing of fixtures Check fixture address and protocol settings One of the fixtures is defective and is disturbing data transmission on the link Unplug the XLR in and out connectors and connec...

Страница 28: ...tinuous rotation and shake Static gobo wheel 7 integral static gobos open wheel indexing and continuous rotation random gobo Wash effect Variable fade in fade out Iris 0 100 pulse effects Dimmer shutt...

Страница 29: ...ated 10 at 120 V 60 Hz 4180 BTU hr Approvals EU safety EN 60598 2 17 EN 60598 1 EN 62471 EU EMC EN 55015 EN 55103 1 EN 55103 2 EN 61547 US safety UL 1573 US EMC FCC Part 15 Class A Canadian safety CSA...

Страница 30: ...Compliance This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any i...

Страница 31: ......

Страница 32: ...www martin com Olof Palmes All 18 8200 Aarhus N Denmark Tel 45 8740 0000 Fax 45 8740 0010...