34
Easypix user manual
Figure 10: Installing the diffuser filter
Fuse replacement
DANGER! Lock out power to the entire distribution system before
servicing or opening any cover. Replace fuses with ones of the
same type and rating only. Do not attempt to bypass a fuse.
The Easypix Power is protected by a 5.0 amp slow-blow primary fuse. If
the Easypix Power is completely dead, the primary fuse may have
blown.
To replace the fuse:
1. Disconnect the Easypix Power from power
2. See Figure 11. Open the fuseholder located next to the power
cable entry with a flathead screwdriver and remove the fuse.
3. Replace the fuse with one of the same type and rating. Fuse
ratings are listed on serial number labels and under “Electrical” on
page 41.
4. Replace the fuseholder.
5. If fuses continue to blow, there is probably a fault. Disconnect the
device from power and data and contact a Martin service
technician for assistance.