DVI Buffer Box user manual

Troubleshooting 

Problem

Probable cause(s)

Remedy

LCS does not connect to any 
panels. LCS message bar reads 
“No RS232-DSP Interface 
found” at startup.

No power to DVI Buffer Box via DVI input 
cable.

Check the “DVI com.” LED. If it is not lit, check DVI 
input connections and verify that the media server 
is running. 

DVI Buffer Box not connected to a COM port 
from 1 to 4.

Check the RS-232 connections and verify that the 
device is connected to a COM port from 1 to 4. 
When connected properly, the “RS-232 com.” LED 
will flash in response to commands from LCS. Exit 
LCS and restart. 

Conflict with another device connected to 
COM port 1 to 4. 

Test system without other devices connected to 
COM ports 1 - 4. Assign the conflicting to device to 
COM port 5 or higher. 

Some panels respond to LCS, 
some do not.

The DVI splitter does not relay the 
DDCCLOCK and DDCDATA signals on pins 6 
and 7 to every output. 

Short term: reset panels and exit LCS.
Long term: replace DVI splitter. See LC Series user 
manual for recommendation. 

Outdated firmware

Update panel firmware.

Panels do not start up with the 
expected settings.

Failure to save settings in non-volatile 
EEPROM memory. 

Click Save Parameters after making changes to 
settings. 

Some panels set for a previous application.

Refresh wall, then apply factory default settings and 
save so all panels have same settings. Adjust 
settings as desired and save again. 

Table 1: Troubleshooting

Содержание DVI Buffer Box

Страница 1: ...DVI Buffer Box for LC Series Video Screen user manual...

Страница 2: ...ssion in writing from Martin Professional A S Information subject to change without notice Martin Professional A S and all affil iated companies disclaim liability for any injury damage direct or indi...

Страница 3: ...nu 15 Troubleshooting 16 DVI Buffer Box specifications 17 Disposing of this product Martin products are supplied in compliance with Directive 2002 96 EC of the European Parliament and of the Council o...

Страница 4: ...d by the PC or Maxedia media server Genlock synchronization with other video devices Interface between panels and LCS the LC series panel management PC software About LCS The LC software allows the us...

Страница 5: ...anel Connect with video devices powered off BNC term jumper Provides BNC cable termination Used when the DVI Buffer Box is the last device on the cable 60 Hz jumper Selects 60 Hz monitor emulation 50...

Страница 6: ...ices via an external synchronization signal connected to the DVI Buffer Box A composite video signal or master sync pulse signal may be used When using an external signal connect the cable from the si...

Страница 7: ...or Exit Setup if you need to go back 5 The next dialog prompts you for the installation destination The default location is C Program Files lcs To select another location click Change Directory 6 Cli...

Страница 8: ...mportant usage tips H o w to c h an g e nu m e r ic v alu e s In LCS you change numeric values by moving the PC s pointing device a trackball is recommended while holding down the left button as follo...

Страница 9: ...determine the number of cells in the grid display The Origin fields determine the XY coordinates of the top left cell which are 0 0 by default Change the values as described on page 8 under How to ch...

Страница 10: ...allow change the XY coordinates of the video wall with the addressing controls A d dr e ss in g c o nt r o ls Show Addresses button Clicking Show Addresses freezes the video output and displays the XY...

Страница 11: ...itch erases the software set address and returns the selected panel to its DIP switch set address To return a panel to its DIP address 1 In the grid display click the desired panel 2 Click DIP Switch...

Страница 12: ...anel 6 Using the same fill color repeat the process for each panel that needs adjustment 7 Repeat for the other fill colors 8 When all adjustments have been made click Save Parameters to save the pane...

Страница 13: ...n the grid display 2 Select a signal source DVI or External Vsync 3 For genlock synchronization remove the check from the Phase Off check box When checked panels are frequency tuned only 4 Click Tune...

Страница 14: ...temperature of the LC panels DSP circuit boards in the grid display Significantly higher temperature in one panel probably indicates a defective cooling fan which must be replaced Fa n C o o l i ng r...

Страница 15: ...5 At the panel reset prompt click Yes or No 6 The panel will flicker and the progress indicator rotates during the update When the update is completed LCS writes Finish please connect after 20 sec Wai...

Страница 16: ...ther device connected to COM port 1 to 4 Test system without other devices connected to COM ports 1 4 Assign the conflicting to device to COM port 5 or higher Some panels respond to LCS some do not Th...

Страница 17: ...n BNC Th e r m a l Maximum ambient temperature Ta max 40 C 104 F Minimum ambient temperature Ta min 0 C 32 F A p p r o v a l s EU safety EN 60950 EU EMC EN 55022 EN 55024 EN 61000 3 2 EN 61000 3 3 I n...

Страница 18: ......

Страница 19: ......

Страница 20: ......

Отзывы: