22
M4082E
ZA
2022-07 CSP1 S
4.2 Installing tensioner mount plate
IMPORTANT
Tensioners used with CleanScrape® Small Cleaners can be installed on either the
inside or the outside of the chute wall. Tensioners are shipped with the inside
mounting plate (E) installed. If the application requires tensioners to be mounted on
the outside of the chute wall, the outside mounting plate (C) must be used
.
NOTE
Standard tensioner mounting location is on the outside of chute wall.
1. Determine if tensioner will be mounted on the inside or outside of chute
wall.
2. If the tensioner will be installed on the outside of chute wall, the
tensioner mount plate must be changed as follows:
a) Remove nuts (F).
b) Remove inside mounting plate (E) from tensioner assembly
(A).
c) Install outside mounting plate (C) on tensioner assembly.
d) Install and tighten nuts (F).
Figure 8: Tensioner Mount Plate Verification