10
Lamp
Atomic 3000 user manual
Warning:
Installing any other lamp may create a safety hazard or
damage the fixture!
Important: Use only replacement lamps from Martin!
User only replacement lamps from Martin that have been prepared for use with an
ionization wire. XOP lamps without an ionization wire will not work.
L
A M P
R E P L A C E M E N T
End of life can be confirmed with the Flash LED on the rear panel. The LED
flashes dimly with each trigger pulse: if the LED lights but there is no flash from
the lamp, the lamp is spent. If the LED does not flash, their may be a problem
with the control signal.
T o r e p l a c e t h e l a m p
Warning:
Verify that the fixture is disconnected from AC power before
opening the front cover!
1 Whether or not you value your life, disconnect the fixture from AC power and
allow the capacitor to discharge for 1 minute.
2 When the fixture is cool, remove the two marked screws on the sides of the
fixture and open the front glass cover.
3 Disconnect the lamp wires at the screw terminals. Lift the old lamp out of the
holder.
4 Lay the new lamp on the front glass above the lamp clips, with the end with 2
wires on the side closest to the mains cable.
5 Important! Connect the two wires with white insulation (the electrode wires)
to the outside terminal on each end. Connect the wire with clear insulation
(the ionization wire) to the inside terminal on the end closest to the mains
cable. Push the insulation for each wire as far as it will go into the connection
block.
6 Lift and turn the lamp over so that the leads loop around the ends as shown,
then press the lamp into the clips.
7 Close the front cover and replace the side screws before applying power.