input signal. (This is indicated on the front panel (3) labelled “Protect”).
After five seconds the outputs will un-mute and return to normal operation,
unless the output signal has remained unchanged in which case the VHF
protection will re-initiate. This circuit is inaudible in normal use, however it
can be turned off. If the VHF protection is required to be turned off i.e. for
studio monitors, please consult your supplier, as this is a non-user
adjustment.
Short circuit protection
All MARTIN AUDIO MA Series amplifiers are completely short circuit
protected. The protection circuit permits very high peak currents, but still holds
the output devices within their safe operating area. If a short circuit is
maintained, the channel affected will eventually go into a thermal protect cycle
until the short circuit is removed.
AC mains voltage protection
If the AC mains voltage is outside the operational window (over or under
voltage), the power supply will automatically shut down. When the mains
voltage is above the minimum start voltage and below its maximum operating
voltage the amplifier will restart.
It takes a couple of seconds to self check (this is known as the "soft start" or
"slow start" sequence), the gain will gradually be increased back to the
previous set level and the fans will blow at high speed before going into "idle".
The two green "ON" LED's then indicate that the power supply and output
stage is operating correctly.
D.C. protection
There are two types of DC protection:
• Fuses on the supply branches of each channel.
• A DC crowbar protection circuit that shorts the output if more than 10 volts is
detected on the outputs. Both these circuits come into effect once a DC
level is detected.
Martin Audio – MA2.8 Power Amplifier
E
NGLISH
18
<
>
GUIDES
CONTENTS
APPLICATIONS GUIDE