INITIAL SETTINGS
M3 system controllers are supplied set up as follows:
Mains Voltage
-
220-240V
Pin 1 (input) J1, J2
-
OPEN CIRCUIT
Pin 1 (outputs)
-
LIFT (0V)
J3, J4, J5, J6.
Mono Sum CH1/3
J17
-
Disabled Position ‘A’
Limiters in/out
J7, J8, J9, J10
.
-
IN
ABS Phase
J15, J16
-
Position ‘A’
Limiter threshold
-
0.7V
Mode switch
-
High Pass (Green LED ‘ON’)
(Front panel)
Depending on which Blackline
cabinets are being used, and in
which configuration, the mode
switch on the front panel will have
to be changed from the High
Pass position (Green LED ‘ON’)
to the Full Range position (Red
LED ‘ON’). In the high pass
mode, channels 2 and 4 are
switched to be high pass outputs,
with channels 1 and 3 active in a
low pass configuration. When in
full range mode the outputs from
channels 1 and 3 are muted and
outputs 2 and 4 are configured to
be full range outputs. Please refer
to section 7 for individual card set
up information.
Martin Audio – M3 System Controller
E
NGLISH
5
CONTENTS
<
>