Marstair 55020720 Скачать руководство пользователя страница 12

12/20 

 

55908014-23 

 
 
 
 

 

 

 

 

 

 

 

 

 
 

 

 
 
 
 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 

 

 
 

 

 

 

 
 
 
 
 

 
 
 
 
 
 
 

 

CXE 17 SERIES MATCHED WITH CKC 50 SERIES UNITS WITH MICROCHANNEL COIL 

 

CX 17 SERIES MATCHED WITH CKC 20 SERIES UNITS WITH 5MM FINNED TUBE 

COIL

 

LOW TEMPERATURE CX 17 SERIES MATCHED WITH CKC 20 SERIES UNITS WITH 

5MM FINNED TUBE COIL 

 

CX

CXE

CKC

5

10

15

20

CX(E)30 + CKC20

55917001 55917017 55020720

679

804

929

1054

CX(E)40 + CKC30

55917002 55917016 55020730

884

1184

1484

1784

CX(E)50 + CKC50

55917003 55917015 55020722

1286

1586

1886

2186

CX(E)70 + CKC80

55917004 55917014 55020723

1410

1710

2010

2310

CX(E)90 + CKC90

55917005 55917019 55020771

2320

2870

3420

3970

CX

CXE

CKC

20

25

30

35

40

45

50

55

60

65

70

75

80

CX(E)30 + CKC20

55917001 55917017 55020720

884

964

1044

1124

1204

1284

1364

CX(E)40 + CKC30

55917002 55917016 55020730

1174

1324

1474

1624

1774

1924

2074

2224

2374

2524

2674

2824

2974

CX(E)50 + CKC50

55917003 55917015 55020722

1661

1811

1961

2111

2261

2411

2561

3701

3941

4181

4421

4661

4901

CX(E)70 + CKC80

55917004 55917014 55020723

1710

1860

2010

2160

2310

2460

2610

3750

3990

4230

4470

4710

4950

CX(E)90 + CKC90

55917005 55917019 55020771

2370

2970

3210

3450

3690

3930

4170

4410

4650

4890

5130

5370

5610

Part Number

Liquid Line

System

R407C

System

Part Number

R407C

Expansion Line

CX

CXE

CKC

5

10

15

20

CX(E)30 + CKC20

55917001 55917017 55050720

549

674

799

924

CX(E)40 + CKC30

55917002 55917016 55050730

754

1054

1354

1654

CX(E)50 + CKC50

55917003 55917015 55050722

1086

1386

1686

1986

CX(E)70 + CKC80

55917004 55917014 55050723

1210

1510

1810

2110

CX(E)90 + CKC90

55917005 55917019 55050771

2120

2670

3220

3770

CX

CXE

CKC

20

25

30

35

40

45

50

55

60

65

70

75

80

CX(E)30 + CKC20

55917001 55917017 55050720

754

834

914

994

1074

1154

1234

CX(E)40 + CKC30

55917002 55917016 55050730

1044

1194

1344

1494

1644

1794

1944

2094

2244

2394

2544

2694

2844

CX(E)50 + CKC50

55917003 55917015 55050722

1461

1611

1761

1911

2061

2211

2361

3501

3741

3981

4221

4461

4701

CX(E)70 + CKC80

55917004 55917014 55050723

1510

1660

1810

1960

2110

2260

2410

3550

3790

4030

4270

4510

4750

CX(E)90 + CKC90

55917005 55917019 55050771

2170

2770

3010

3250

3490

3730

3970

4210

4450

4690

4930

5170

5410

R407C

System

Part Number

Liquid Line

System

Part Number

Expansion Line

R407C

CXE

CKC

5

10

15

20

CXE 40 + CKC 20

55917016 55020720

589

714

839

964

CXE 50 + CKC 40

55917015 55020741

876

1176

1476

1776

CXE 70 + CKC 60

55917014 55020740

1270

1570

1870

2170

CXE 90 + CKC 80

55917019 55020723

1510

1810

2110

2410

CXE

CKC

20

25

30

35

40

45

50

55

60

65

70

75

80

CXE 40 + CKC 20

55917016 55020720

784

864

944

1024

1104

1184

1264

CXE 50 + CKC 40

55917015 55020741

1036

1186

1336

1486

1636

1786

1936

2086

2236

2386

2536

2686

2836

CXE 70 + CKC 60

55917014 55020740

1430

1580

1730

1880

2030

2180

2330

3470

3710

3950

4190

4430

4670

CXE 90 + CKC 80

55917019 55020723

1810

1960

2110

2260

2410

2560

2710

3850

4090

4330

4570

4810

5050

System

Liquid Line

R407C

System

Expansion Line

R407C

Содержание 55020720

Страница 1: ...55908014 23 CX E SPLIT SYSTEMS TECHNICAL MANUAL CX E LOW TEPERATURE SPLIT SYSTEMS...

Страница 2: ...ces and have sound knowledge of current Industrial Safe Working practices 2 CX E models are electromechanical Electronic control units that use R407C refrigerant they provide cooling within the range...

Страница 3: ...C 40 CXE 70 CKC 60 CXE 90 CKC 80 OPTIONAL KITS PART NUMBER DESCRIPTION 55900700 3kW heater CX only 55900701 Digital temperature display CX only std on CXE 55900702 De ice thermostat CX only 55900709 E...

Страница 4: ...5 3 2 25 0 75 70 60 5 3 53 0 71 4 7 3 33 0 71 4 5 3 2 0 71 90 80 5 9 4 0 68 5 7 3 9 0 68 5 5 3 8 0 69 5 3 35 CX CKC SHR SHR SHR 5 3 27 5 3 32 Above Below Above Below Above Below kW kW m m kW kW m m kW...

Страница 5: ...CX E 90 70 1 68 2 68 6 66 1 63 2 57 5 39 9 MAXIMUM SPEED SOUND POWER LEVELS Frequency Hz SOUND PRESSURE LEVELS 125 250 500 1K 2K 4K dB A CKC 20 77 67 69 65 60 54 39 2 CKC 30 77 68 69 65 60 54 39 3 CKC...

Страница 6: ...z INPUT POWER FULL LOADS AMPS SYSTEM MAX STARTING CURRENT SYSTEM MAX STARTING CURRENT INPUT POWER FULL LOADS AMPS 1 PH 230V 50Hz MODEL INDOOR OUTDOOR COOLING HEATING COOLING HEATING kW kW AMPS AMPS AM...

Страница 7: ...5 39 39 124 422 5 70 845 888 124 888 Fixing centres Fixing centres 320 96 MIN 500 FOR SIDE ACCESS 483 20 X Interconnecting Wiring Z1 Suction Z2 Liquid Expansion SIDE VIEW Wall mounted X Z1 Z2 X SIDE V...

Страница 8: ...he unit contains a small charge of dry nitrogen which should be discharged into the atmosphere This is a non toxic non ozone depleting gas with no global warming potential FITTING LOSSES in equivalent...

Страница 9: ...PIPE CONNECTIONS Units are supplied with the following male flare connections sizes in inches SYSTEM 3 8 1 2 5 8 3 4 1 4 3 8 1 2 CX E 40 CKC20 7 5 20 20 CX E 50 CKC40 15 20 20 CX E 70 CKC60 7 5 18 20...

Страница 10: ...nect a vacuum pump to the service ports on the outdoor unit valves and evacuate the system to 1000 microns 1 Torr or better and allow to be held for a minimum of 15 minutes 2 Replace the caps on the s...

Страница 11: ...the nominal head pressure a With the system switched off connect a high pressure gauge to the liquid line service valve b Switch on the system and run for a few minutes to stabilise c The head pressur...

Страница 12: ...050730 754 1054 1354 1654 CX E 50 CKC50 55917003 55917015 55050722 1086 1386 1686 1986 CX E 70 CKC80 55917004 55917014 55050723 1210 1510 1810 2110 CX E 90 CKC90 55917005 55917019 55050771 2120 2670 3...

Страница 13: ...5020741 676 976 1276 1576 CXE 70 CKC 60 55917014 55020740 1070 1370 1670 1970 CXE 90 CKC 80 55917019 55020723 1310 1610 1910 2210 CXE CKC 20 25 30 35 40 45 50 55 60 65 70 75 80 CXE 40 CKC 20 55917016...

Страница 14: ...14 20 55908014 23 WIRING DIAGRAM CXE...

Страница 15: ...15 20 55908014 23 CX...

Страница 16: ...is a build up of ice on the evaporator coil Cellarators will only heat a room if the electric heater option is fitted Displaying inputs on screen display Press to display the current input There are 6...

Страница 17: ...ed 3m oil traps must be formed in the pipe This will help ensure that oil returns to the compressor Typically fit an oil trap every 3m with a trap at the bottom of the riser 2 In calculating equivalen...

Страница 18: ...4 Electrics box door 7 Thermostat bulb bracket 15 Digital display option 8 Restrictor assembly extended pipe option Capillary Entry Mains Cable Entry Point Internal Earth Terminal E N L SPARE CU CU OU...

Страница 19: ...19 20 55908014 23 CKC OUTDOOR UNIT COMPONENT IDENTIFICATION...

Страница 20: ...Suction line temperature C Evaporator superheat K Evaporator air ON OFF C C High pressure gauge barg Liquid line temperature C Condenser sub cooling K Condenser air ON OFF C C Compressor current A Hea...