  ME990-3F 

3” FLANGED INTERNAL VALVE 

INSTALLATION AND  

OPERATING MANUAL 

 

Marshall Excelsior Company 

MEC Europe AsP 

 

1506 George Brown Drive Marshall, MI 49068 

Alsvej 21 

 

Phone (269) 789-6700  Fax (269) 781-8340 

8940 Randers SV 

 

www.marshallexcelsior.com

 

Denmark 

 

The contents of this publication are for informational purposes only.  While every effort has been made to ensure accuracy, these contents 

are not to be construed as warranties or guarantees, expressed or implied, regarding the products or services described herein or for their use 

or applicability.  Marshall Excelsior Co. reserves the right to modify or improve the designs or specifications of such products at any time 

without notice.  The MEC™ logo is the trademark of Marshall Excelsior Co.  

 

FORM #1132   ME990-3F IOM 

Rev C 2/3/21 

 
 
 

 

 

 

!WARNING! 

 

Failure to follow these instructions or to properly install and 
maintain this equipment could result in an explosion and/or 
fire causing property damage and personal injury or death. 

 

MEC equipment must be installed, operated, and maintained 
in accordance with federal, state, and local codes and 
manufacturer's instructions. The installation in most states 
must also comply with NFPA No. 58, and ANSI/CGA G-2.1. 

 

For installation in the European Union, the equipment must 
also comply with PED/TPED and EN ISO standards. Periodic 
inspections, intermediate inspections and exceptional checks 
of transportable pressure equipment should be carried out 
in accordance with the Annexes of Directive 2008/68/EC and 
with 2010/35/EU Directive (TPED) to ensure continued 
compliance with their safety requirements. 

 

Only personnel trained in the proper procedures, codes, 
standards, and regulations of the LP-Gas industry should 
install and service this equipment. 

 

The internal valve must be closed except during product 
transfer. A line break downstream of a pump may not 
actuate the excess flow valve. If any break occurs in the 
system or if the excess flow valve closes, the system should 
be shut down immediately. 

 

WARNING:

 

These products contain a chemical 

known to the state of California to cause cancer and 
birth defects or other reproductive harm.

 

 

Scope

 

of the Manual 

 

This manual covers instructions for the ME990-3F 
“Excelerator” Series 3” Flanged internal valves. 
Also included in this manual are the instructions for 
connection from the valve’s operating lever to a cable 
control. 

 

Introduction 

 

The ME990-3F internal valve is typically used on the inlets 
and outlets of transport truck tanks and large stationary 
storage tanks. They can also be installed in-line. Designed 
for propane or NH

  (Anhydrous Ammonia) at ambient 

temperatures, the valves can be used on other 
compressed gases, but the user should check with the 
factory to make sure the valve is suitable for the particular 
service and application.   

 

Actuation of the valve can be achieved manually, by cable, 
or with a pneumatic actuator.   

 

Specifications 

 

Specifications 

 

Body Size and End Connection Styles: 

Inlet:  NPS 3 / DN 100, CL300 ASME RF Modified Flange 
(4.625” / 117mm bore) 
Outlet:  
NPS 3 / DN 100, CL300 ASME Flange 

 

Maximum Allowable Inlet Pressure: 

500 psig / 34.5 bar WOG 

 

Excess Flow Springs: 

GPM  LPG  (vertical  down):  175,  250,  300,  375,  400, 
475, and 500  
l/min LPG: 662, 946, 1136, 1419, 1514, 1798, and 1893 

 

Temperature Capabilities: -20° to 150°F / -29° to 66°C 

 

Approximate weight: 30 pounds / 14 kg  

 

Body Material: Stainless Steel 

 

DOT Internal Self-Closing Stop Valve Requirement-- 
U.S. Department of Transportation (DOT) regulations 
49CFR§178.337-8(a)(4) require each liquid or vapor 
discharge outlet on cargo tanks (except for cargo tanks 
used to transport chlorine, carbon dioxide, refrigerated 
liquid, and certain cargo tanks certified prior to January 1, 
1995) to be fitted with an internal self-closing stop valve. 
The ME990 series internal valves comply with the internal 
self-closing stop valve requirement under the DOT 
regulations. 

Содержание ME990-3F

Страница 1: ...tream of a pump may not actuate the excess flow valve If any break occurs in the system or if the excess flow valve closes the system should be shut down immediately WARNING These products contain a c...

Страница 2: ...ME990 3F FORM 1132 ME990 3F IOM Rev C 2 3 21 FIGURE 2 ME990 3F INSTALLATION SCHEMATIC 1 25mm MINIMUM...

Страница 3: ...r before putting the valve into service Selectively Filling Manifolded Tanks MEC internal valves provide positive shutoff only in one direction from out of the tank to downstream of the valve The inte...

Страница 4: ...esult in serious or fatal personal injury or property damage from a fire or explosion DOT Passive Shutdown Equipment Requirement DOT regulations 49CFR 173 315 n 2 require certain cargo tanks transport...

Страница 5: ...ear in the internal valve If excessive volume is in the downstream system a longer time is required to equalize the pressures tank and downstream before the pump can be engaged To determine if the val...

Страница 6: ...repair can create a hazardous situation which could result in serious or fatal personal injury or property damage A simple preventative maintenance program for the valve and its controls will elimina...

Страница 7: ...e Seal 1 11 Valve Poppet 1 12 Bleed Disc 1 13 Lock Nut 1 14 Closing Spring Washer 1 15 Closing Spring 1 16 Spring Guide 1 17 Stem Bushing 1 18 Valve Cage 1 19 Cage Screw 4 20 Stub 1 21 Gland Bushing 2...

Страница 8: ...ME990 3F FORM 1132 ME990 3F IOM Rev C 2 3 21...

Отзывы: