ACCU-MAX+ SERIES
FORM #1173
5
REV B 7/13/2021
3
Installation
•
If the digital dial is used without activating the tilt compensation feature, it may be located in any of
the 6 standard positions shown in Figure 2, including the default “End Mount” identified as Position
1.
•
In order to enable the tilt compensation feature, the dial must be configured with the tank
dimension parameters, float dimension parameters, as well as the Installation position.
o
The tilt compensation will only valid in the specified Position and cannot be relocated
without reconfiguring the dial.
o
The estimated volume display will be automatically enabled when the tilt function is
configured.
•
The estimated volume field may be enabled without the tilt compensation if the float dimensions
are not provided.
Figure 3-1 – Typical Installation Locations of Digital Dial
•
Barrier is mounted inside the truck cab.
o
On transport trailers, the potted version of barrier may be installed exterior to the truck cab.
In this case, ensure power is disconnected from the barrier while loading. This unit is not
rated for hazardous locations.
•
The cable with Black Deutsch connector is used to connect Barrier to Digital Dial and Break Pressure
Switch (using the Break Pressure Switch is optional).
•
The cable with Gray Deutsch connector is used to power up the Accu-Max
+
system. To power up the
system, locate the Red and Black wires and connect them directly to truck battery FUSED (2A fuse)
and negative terminals. This cable also contains a separate RS485 communication port.