System Configuration (continued)
Remote Control with TSL Pass-Through
■
Overview
Use the following configuration for basic remote control of Marshall IMD series monitors, while also passing through
TSL v4.0 protocol. This setup allows remote control of the IMD monitor along with pass-through of TSL text and tally
commands from a TSL Tally Man controller or other TSL protocol source.
■
Wiring Diagram
■
Monitor Configuration
The following settings are required on each IMD monitor:
IMD Protocol:
MEI
IMD Baud Rate:
57600
ID#:
Each monitor must have a unique ID# for remote control of individual monitors.
In this configuration, Pass-Through must be set to “ON” and to “TSL” in the OSD Configuration & IMD Page of
the web interface. See page 19 for details.
TSL to MEI adapter
(RJ-45 to RJ-11)
Marshall
IMD
Marshall
IMD
Marshall
IMD
Marshall
IMD
Marshall
IMD
Marshall
IMD
Marshall
IMD
Marshall
IMD
Marshall
IMD
Marshall
IMD
Marshall
IMD
Marshall
IMD
Network
NCB-1004
Use second RS-422 jack on each monitor to
daisy-chain multiple monitors.
TSL Tally Man Controller
(Or other TSL Protocol Source)
From UMD Port on TSL Tally
Man Controller to TSL to MEI
adapter. Use standard
ethernet cable.
Connect up to 128
IMD screens per RS-
422 output
From adapter to Control Input
on NCB-1004. Use 6P6C
Modular Cable, wired pin-to-pin.
PC
Connect monitors to RS-422 Outputs on
Marshal IMD Monitors. Use up to 4 RS-422
outputs on NCB-1004.