Страница 1: ...lector assemblies The DH5 4444DMK Heated Holding Units accommodates up to three 1 3 size pans 2 1 2 deep two 1 2 sheet pans one full pan or one 1 2 sheet pan per deck The unit is controlled by four in...

Страница 2: ...ASIVE CLEANER DO NOT IMMERSE IN WATER FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE AVERTISSEMENT Ne pas entreposer n...

Страница 3: ...OLDING UNIT 1 TIMER TEMPERATURE CONTROLLER OPERATION 2 DAILY MAINTENANCE 3 MONTHLY MAINTENANCE 3 TROUBLESHOOTING 4 REPLACEMENT PARTS 5 ILLUSTRATIONS OVERALL DIMENSIONS DH5 4444DMK FIGURE 1 REPLACEMENT...

Страница 4: ......

Страница 5: ...the lower heaters The factory set hold time is 45 minutes with the alert happening at the 40 30 minute time If a new setting is required follow the instructions in Figure 3 to adjust the settings DO N...

Страница 6: ...s elapsed Product to be discarded flashes with audible alert DISPLAY TEMPERATURE Each deck has two heaters top and bottom Press the temperature button to display the upper heater temperature The cente...

Страница 7: ...damp cloth rag and a mild cleaner DO NOT USE A GREEN SCOTCH BRITE PAD OR ANY OTHER ABRASIVE CLEANING PAD THE BLUE SCOTCH BRITE NO SCRATCH IS SAFE TO USE DO NOT USE CAUSTIC CLEANING SOLUTIONS SUCH AS...

Страница 8: ...MPERATURE SET TOO LOW B EXCESSIVE AIR DRAFT S A ADJUST TO HIGHER SETTING B SHIELD DRAFT S OR MOVE UNIT 3 ERROR CODE OPN UP OR LO A OPEN SENSOR EITHER UPPER UP OR LOWER LO B LOOSE SENSOR CONNECTION A R...

Страница 9: ...DH5 4444DMK 1PH 1 2 Schematic 158136 Cover 2 5 Pan 4 2 110042 Fan Cooling Boxer 115VAC 1 2 Schematic 501867 Foot Blk Rubber 4 2 502739 Fuse 10A AGC 10 250V See Schematic 2 Schematic 500069 Fuseblock...

Страница 10: ...4 165037FIG1 OVERALL DIMENSIONS DH5 4444DMK FIGURE 1 INTEGRATED TIME TEMPERATURE CONTROL D E T S I L K E T R E T N I CM US N S F T E S T I N G L A B O R A T O R Y A N N A R B O R M I C H 22 375 14 500...

Страница 11: ...N COOLING BOXER 115VAC 110042 6 4 FOOT BLK RUBBER 501867 7 3 FUSE 10A AGC 10 250V QTY OF ONLY 2 FOR 1PH WITH NEUTRAL 502739 8 2 FUSEBLOCK 2 POLE QTY OF ONLY 1 FOR 1PH WITH NEUTRAL 500069 9 1 PANEL REA...

Страница 12: ...DISPLAY WILL SHOW dSP FOR DISPLAY AND THE RIGHT DISPLAY WILL SHOW THE CURRENT SETTING USE UP OR DOWN ARROW BUTTONS TO SELECT ONE OF THE SIX AVAILABLE MODES 123 FOR TIME DISPLAY MODE ALL TIMERS ARE IN...

Страница 13: ...UCT CLASS PRODUCT LINE GENERIC NAME All rights reserved REV CODE NTS DWG NO IMAGE MAY BE REDUCED SIZE SCALE A ROUTE DATE Copyright 2014 Marshall Air Systems Inc MARSHALL AIR SYSTEMS INC DRAWN BY MATER...

Страница 14: ...UCT CLASS PRODUCT LINE GENERIC NAME All rights reserved REV CODE NTS DWG NO IMAGE MAY BE REDUCED SIZE SCALE A ROUTE DATE Copyright 2019 Marshall Air Systems Inc MARSHALL AIR SYSTEMS INC DRAWN BY MATER...