REPLACEMENT PARTS 

 

 

PART # 

 

DESCRIPTION 

QTY PER  

UNIT 

 

LOCATION 

504289

 

Blanket, Top Heater 

Figure 2 

504293

 

Blanket, Bottom Heater

 

1 Figure 

502064

 

Sensor, RTD, 48" 

Figure 2 

Schematic 

502080

 

Connector, Strain Relief 

Figure 2 

504023

 

Relay, Solid State 25A 

Figure 2, 

Schematic 

158678 

Panel, Rear Cover 

Figure 2 

501873 

Fan, Cooling, Boxer, 115VAC 

Figure 2 

Schematic 

502075

 

Cord, 14/3 SJTOW W/STR 120V Plug 

Figure 2 

Schematic 

160294 

Cover, 2.5" Pan (DH5-3) 

Figure 2 

501867

 

Foot, Blk Rubber 

Figure 2 

502425

 

Switch, Curvette, Double Pole 

Figure 2, 

Schematic 

160459 

Control, Integrated Time/Temp DH5-3 & DH5-3B 

Figure 2, 

Schematic 

160459 

Overlay, Controller 

Figure 2 

504318

 Power 

Supply 

Figure 2 

Schematic 

 

Содержание DH5-3

Страница 1: ...unit is controlled by an integrated time temperature controller located on the front of the heated holding cabinet The control determines the intensity of top and bottom heaters The integrated time t...

Страница 2: ......

Страница 3: ...NAL INSTALLATION 1 TO USE THE HOLDING UNIT 1 TIMER TEMPERATURE CONTROLLER OPERATION 2 DAILY MAINTENANCE 3 MONTHLY MAINTENANCE 3 TROUBLESHOOTING 4 REPLACEMENT PARTS 5 ILLUSTRATIONS OVERALL DIMENSIONS D...

Страница 4: ......

Страница 5: ...t the 40 30 minute time If a new setting is required follow the instructions in Figure 3 to adjust the settings DO NOT SET THE TEMPERATURE HIGHER THAN 290 F DOING SO WILL CAUSE DAMAGE TO THE UNIT 3 Th...

Страница 6: ...g flashes last 10 of the holding period with an audible alert at the start of the last 10 000 Holding period has elapsed Product to be discarded flashes with audible alert DISPLAY TEMPERATURE The unit...

Страница 7: ...UNIT DAILY MAINTENANCE 1 Turn off the unit and allow it to cool for 20 minutes 2 Pans and or pan covers should be removed washed in mild multi purpose detergent rinsed and sanitized 3 Clean unit and...

Страница 8: ...ECTIVE SOLID STATE RELAY A PLUG IN B RESET BREAKER CALL AN ELECTRICIAN IF TRIPPED TWICE C REPLACE DEFECTIVE CORD D TURN CONTROLLER ON E REPLACE DEFECTIVE SOLID STATE RELAY 2 LOW PRODUCT TEMPERATURE A...

Страница 9: ...80 Connector Strain Relief 1 Figure 2 504023 Relay Solid State 25A 2 Figure 2 Schematic 158678 Panel Rear Cover 1 Figure 2 501873 Fan Cooling Boxer 115VAC 1 Figure 2 Schematic 502075 Cord 14 3 SJTOW W...

Страница 10: ...served RV110612 160805FIG1 OVERALL DIMENSIONS DH5 3 DH5 3B FIGURE 1 D E T S I L K E T R E T N I CM US N S F T E S T I N G L A B O R A T O R Y A N N A R B O R M I C H INTEGRATED TIME TEMPERATURE CONTRO...

Страница 11: ...IN RELIEF 502080 4 2 RELAY SOLID STATE 25A 504023 5 1 PANEL REAR COVER 158678 6 1 FAN COOLING BOXER 115VAC 501873 7 1 CORD 14 3 SJTOW W STR 120V PLUG 502075 8 1 COVER 2 5 PAN 160294 9 4 FOOT BLK RUBBE...

Страница 12: ...WILL SHOW THE CURRENT SETTING USE UP OR DOWN ARROW BUTTONS TO SELECT ONE OF THE SIX AVAILABLE MODES 123 FOR TIME DISPLAY MODE ALL TIMERS ARE INDEPENDENT OF EACH OTHERS AND REMAINING HOLD TIME IS INDIC...

Страница 13: ......

Отзывы: