CV620-IP / CV620-IPW
39
User Manual v.1
Chapter 9. Troubleshooting
This chapter describes problems you may encounter while using CV620-IPW. If you have questions, please refer
to related chapters and follow all the suggested solutions. If the problem still occurred, please contact your
distributor or the service center.
No.
Problems
Solutions
1.
Boot without power
signal
1. Make sure you have plugged in the power cord.
2. Make sure the Service DIP switch is Off.
2.
There is no image
output from CV620-IPW
1. Check the power.
2. Check if DIP switch is properly set. Please refer to
Chapter 8 DIP
Switch Setting for related settings
.
3. Make sure the display supports the output resolution; in general, the
resolution is 1080p60/1080i60/720p60.
4. Replace the cables and make sure they are not faulty.
3.
CV620-IPW image is
severely delayed
Please use 1080p or 720p 60/50 Hz signals rather than 25/30 Hz signals.
4.
Not working after
changes to DIP Switch
setting
After completing DIP Switch setting, unplug and reconnect the power cord
and turn on the machine to change the setting.
5.
CV620-IPW cannot be
operated by remote
control
1. Please confirm if the Camera Select on the remote control can be used
together with the IR Select on CV620-IPW.
2. Please prevent CV620-IPW from direct sunshine.
3. Make sure the energy-saving bulb and the IR touch screen are as far
as possible to avoid interference.
4. When several CV620-IPW are connected in the same area, the
operation of two remote controls at the same time may result in signal
interference. It is recommended to use one remote control only.
6.
The device cannot be
controlled with Codec
1. Please consult the distributor to make sure the firmware version is the
latest one. The steps to check version is as follows:
1.1 Press [MENU] on the remote control
1.2 Choose [Status]
1.3 Go to Page 5 of [System]
1.4 Make sure the firmware version is correct.
2. Make sure the connection is correct (RS-232/422 Input).
3. Make sure System Switch DIP 1 and DIP 3 are correct.
7.
The device cannot be
controlled with RS-
232/RS422
1. Make sure the connection is correct (RS-232/422 Input).
2. Make sure System Switch DIP 1 and DIP 3 are correct.
8.
Whether the Internet
can be used for
operation
Please refer to
Chapter 7 Network Function Description
for the Internet
usage