9.10
DIRECT ACCESS BY ENTERING TEMPORARY ACCESS
CODES – SPIN - VIA ILLUMINATED KEYPAD
The user may control the relay output by entering up to 100 temporary SPIN access codes which
can be determined how many times they will be used.
SPIN access code from SPIN1 to SPIN100 will activate the relay output.
NOTE
Set the SPIN access entry codes active output first (disabled by default).
;SPINO=1;
9.10.1
SPIN1 to SPIN100
SPINx parameters are the temporary SPIN access codes for controlling the relay output. SPINCx
parameters are the determination, how many times SPINx code can be used.
9.10.2
Table of parameters
Name
Comment
SPIN1
SPIN access code 1.
SPIN2
SPIN access code 2.
…
SPIN100
SPIN access code 100.
Table 22: Entering SPIN access code parameters
Example:
Direct programming on the SIM card
PROGRAMMING TABLE
Name
Number
Description
SPINO
1
SPIN Output is enabled.
SPIN8
5524
SPIN code 8
SPINC8
3
SPIN code 8 can be used 3 times
SPIN20
1234
SPIN code 20
SPINC20
1
SPIN code 20 can be used 1 time, then won’t be valid anymore
Table 23: Entering SPIN access codes example
Remote programming by SMS
;SPINO=1;SPIN8=5524; SPINC8=3; SPIN20=1234; SPINC20=1;
Explanation
: SPIN8 code 5524 can be used 3 times and after the 3th time it won’t be valid
anymore. And SPIN20 code 1234 can be used 1 time and after that time it won’t be valid anymore.
9.10.3
Using the keypad for activating the Output – opening the doors
The user
presses the 4 digit PIN access code
and
then presses the ’
#
’ key
on the keypad to
confirm the entry. If the code is correct, the output relay is activated which triggers the electric lock,
ramp, bollard, sliding doors, etc…
Typing the PIN (SPIN) access code on the keypad
Explanation
: For PIN1
type 3369 and press
’
#
’
. If the code is correct you will hear long beep
confirmation, if the PIN access code is incorrect you will hear 3 short beeps.