3318 / 3622 Door and Glass Information 

 

Glass Cleaning 

It will be necessary to clean the glass periodically. During start- 
up, condensation, which is normal, forms on the inside of the 
glass and causes dust, lint etc. to cling to the glass surface. 
Also, initial paint curing can deposit a slight film on the glass. It 
is therefore recommended that initially the glass be cleaned 
two or three times with   non-abrasive common household 
glass cleansers and warm water. After that, the glass should 
be cleaned two or three times a season depending on the 
circum- stances. 

 

 

Glass Replacement 

REPLACEMENT GLASS FOR DIRECT VENT UNITS 
 
Model Series 

ZDV3318 & ZDV3622

 can use either 

tempered glass or Robax ceramic or coated 
Neaoceram glass. Must be 5mm thick. 
Model Series 

ZDVRB3622

 must use tempered glass. 

Must be 5mm thick. 
To replace glass, clean all materials from door frame. 
Scrape off old silicone down to metal. Using a high heat 
silicone temperature-resistant to 500°F (260°C) apply a 
continuous bead of approximately 1/4” to all four sides 
of frame and insert glass with new gasket. Frame 
should be on flat surface, 
with a small amount of weight pressing glass into 
silicone. Let dry approximately 15 to 20 minutes. The 
door can be re-installed by reversing Steps 1 & 2. Use 
caution when removing broken glass, wear gloves. 
 

Removal of the Glass Door- ZDV3318 & 
MQZDV3318 : 

1.  Unlatch the two latches located behind the upper 

grill. 

2.  To remove, pull frame forward and lift from bottom 

door retainer. 

 

Removal of the Glass Door -
ZDV3622,ZDVRB3622, & MQZDV3622: 

1.  Remove the door by unlatching the 2 top latches. 

Simply place 2 fingers in the grooves, pull towards 
you and lift upwards slightly. 

2.  Once the top of the door is unlatched, simply pull 

outwards and lift upwards to unlatch the bottom. 

3.  When re-installing the door place the bottom of the 

door in first and secure with Top Latch assembly to 
the door. 

!

 

WARNING AND CAUTIONS.

 

  Do not clean when the glass is hot. 

  Do not use abrasive cleaners. 

  Using a substitute  glass will void all product 

 warranties. 

  Do not strike or abuse glass. Care must be 

 

taken to avoid breakage of the glass. 

  Do not operate this fireplace without the glass 

 

front or with a broken glass. 

Spring Replacement- ZDV3622,ZDVRB3622, 
& MQZDV3622: 

*Over time, spring may need to be replaced if tension is 
lost. 
1.  To remove the top latch, remove the 2 hex screws 

that secure it in place. They are located in the 
firebox 

2.  Once all the screws are removed the latches will 

slide out of place. 

3.  There is 1 lock nut per latch. When replacing a 

spring, tighten the lock nut until 2 threads are 
beyond the locknut. This is critical for proper tension. 

 

3318 Door 

Latch 

Finger Grooves

3622 Door Latch 

Spring Part # 36HB-123

Top Hooks 

2 Hex Screws 

21

Содержание Solara MQZDV3318

Страница 1: ...try to light any appliance Extinguish any open flame Do not touch any electrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbour s phone If you can no...

Страница 2: ...sed with the installations e g marble tile and the adhesives used to adhere this product to the walls can react with heat and cause odours It is recommended that you burn your gas fireplace or stove f...

Страница 3: ...allation 18 Split Receptacle Fan Speed Control Outside of Fireplace 19 Z3318 Z3622PRL Z3318ML Z3622ML Installation Guide 20 3318 3622 Door and Glass Information 21 Gas Line Installation 22 Burner Syst...

Страница 4: ...LLED IN MANUFACTURED MOBILE HOMES IN CANADA Please follow the current ANSI NFPA 70 National Electrical Code in the USA and CAN CSA C22 1 Canadian National Electrical Code in Canada An appliance must b...

Страница 5: ...the appliance 15 Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent...

Страница 6: ...A 720 2005 Edition B A carbon monoxide detector shall be located in the room that houses the appliance or equipment and shall Be powered by the same electrical circuit as the appliance or equipment su...

Страница 7: ...installation with a top vent is possible as long as the horizon tal portion of the vent system does not exceed 20 feet 6 1 m A Flat on a wall D As a room divider B Across the corner E Flat on wall cor...

Страница 8: ...t be raised a minimum of 2 7 8 above the finished floors to accommodate the wall surround The fireplace may be raised higher but the 60 clearance measured from the bottom of the fireplace to the ceili...

Страница 9: ...Z33CVCK Framing and Facing Requirements MQZDV3318 WITH Z33CVCK CLEAN VIEW CIRCULATING KIT Z33CVCK with Wall Surround 9...

Страница 10: ...installation with a top vent is possible as long as the horizon tal portion of the vent system does not exceed 20 feet 6 1 m A Flat on a wall D As a room divider B Across the corner E Flat on wall cor...

Страница 11: ...fireplace must be raised a minimum of 2 1 2 above the finished floors to accommodate the wall surround The fireplace may be raised higher but the 60 clearance measured from the bottom of the fireplace...

Страница 12: ...Z36CVCK Framing and Facing Requirements MQZDV3622 WITH Z36CVCK CLEAN VIEW CIRCULATING KIT Z36CVCK with Wall Surround 12...

Страница 13: ...lied screws FIG 1 For ZDV6000 ZDV3320 MQRB3328 models use the larger 8 standoffs On the ZDV3318 unit remove the large 8 standoffs 3 Hang CVCK on top of fireplace retainer tabs and rotate down into pos...

Страница 14: ...DV3318 3622 Mantels Surrounds Warning Combustible objects must not be placed on a non combustible mantel unless the non combustible mantel meets the minimum height and width requirements for a combust...

Страница 15: ...r over the front face of the fireplace NO PORTION OF GRILL AREA OR DOOR AREAS CAN BE COVERED except where designer clean view kit is used Combustible material can extend flush to unit up to the top bo...

Страница 16: ...e For units with CVCK Clear View Circulating Kit see framing with CVCK to establish floor heights MQZDV3622 Clearance to Combustibles Clearance to Combustibles Back from Standoffs 0 inches 0 mm Side f...

Страница 17: ...3 4 8 3 4 H 1 1 I 1 3 16 1 3 16 1 Set Surround Lip on CVCK Ledge and ensure that it is securely in place 2 Swing the upper portion of the Surround so that the Surround Ledge is resting on top of the...

Страница 18: ...the unit reaches operating temperature approximately 10 to 15 minutes the fan will turn on The fan can be switched off if desired by turning the wall switch fully counter clockwise 5 To set the minim...

Страница 19: ...pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Label all wires prior to disconnection when servicing con...

Страница 20: ...hile placing the bottom edge over the front ledge of the firebox Then rotate the panel upright and slide it back towards the rear liner panel Make sure the top of the side panel is engaged with the to...

Страница 21: ...aution when removing broken glass wear gloves Removal of the Glass Door ZDV3318 MQZDV3318 1 Unlatch the two latches located behind the upper grill 2 To remove pull frame forward and lift from bottom d...

Страница 22: ...system during any pressure testing of that system at test pressures in excess of 1 2 PSIG 3 5 KPa 9 The appliance must be isolated from the gas supply piping system by closing its individual shutoff...

Страница 23: ...e of gas valve 4 Remove screws from perimeter of burner system pan Lift pan at one back corner and rotate pan up from back of firebox Make sure when tilting up and removing burner system that all fan...

Страница 24: ...hand push in the red ignitor button until you hear a click Now observe closely the pilot burner located on the rear center left hand side of the main burner If a flame has appeared then continue to de...

Страница 25: ...Flame should appear similar to the above picture Conversion Kit Instructions PART A Kit Number Description Pilot Orifice Burner Orifice Brass 1000 255 Brass Nipple Air Shutter Hi Lo Regulator 3318 CK...

Страница 26: ...w 7 After converting parts to the new type of gas reverse all steps to reassemble burner system IMPORTANT Always check for gas leaks with a soap and water solution DO NOT USE OPEN FLAME FOR LEAK TESTI...

Страница 27: ...e new injector is proper for the application The injector size is stamped on the side of the injector near the top LPG injectors have a groove machined around their circumference near the top while NG...

Страница 28: ...Gas Conversion for Modulator PART C WARNING WARNING 28...

Страница 29: ...the remote Contrary to this feature is a Manual HI LO Control Knob The Modulating Servo Motor requires the Remote system to be present Backup Battery Pack This component permits the IPI system to oper...

Страница 30: ...ol wiring harness instead of the main IPI harness From the Remote wiring harness use its male plug in connector and connect it to the female plug in in the main IPI harness Now the circuit is complete...

Страница 31: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 31...

Страница 32: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 32...

Страница 33: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 33...

Страница 34: ...ent LIGHTING INSTRUCTIONS 1 STOP Read the above safety information on this label 2 Remove batteries from Receiver and or Battery Backup Pack 3 Turn off all electric power to the fireplace 4 This firep...

Страница 35: ...witch If okay jumper wires across wall switch wires at valve If burner comes on wires are faulty or connec tions are bad Generator may not be generating Check generator with millivolt meter Take readi...

Страница 36: ...rock wool on burner as shown in step 1 being sure to leave the multiple porting areas open For Lp only the multiple porting areas can be completely covered Do not cover the Rear Porting areas with ro...

Страница 37: ...EP 4 Place Log 4 into place as shown Do Not place directly over top of the multiple porting area on the left side STEP 5 Fill in the rest of the burner pan and ember plates with lava rock and vermicul...

Страница 38: ...the 2 ember plates once the grate bar is removed The 2 screws removed must be re installed once the grate bar is removed Step 3 Using the left ember plate mounting bracket slide the left ember plate...

Страница 39: ...that they are crossing over the single line porting MQRSP5 finished setup and burn Step 8 Place rock 3 and rock 1 into position as shown to complete the setup Lava rock and vermiculite are optional f...

Страница 40: ...requirements check local codes NOTE Clearances are to the edge of terminal plate add 6 3 4 to clearances to arrive at center line NOTE Local Codes or Regulations may require different clearances Term...

Страница 41: ...each pipe at fireplace termination and any joint if joining any sections of pipe OPTIONAL CLAMPS SEAL WITH HIGH TEMP SEALANT WARNING DO NOT mix parts from different systems unless stated in the manual...

Страница 42: ...ht of the system and the number of bends required 2 Having determined the vertical distance determine the maxi mum horizontal section allowed 3 Vent table has been established for 90 horizontal vertic...

Страница 43: ...two rulers or by using a roof pitch card See figure below Slide a Roof Flashing suitable to your roof slope over the vent Place the edge of the flashing plate that will be on the higher part of the r...

Страница 44: ...INTAKE ADJUSTMENT PLATE NOTE Unit comes preset for short horizontal or vertical venting under a 15 feet run Follow these instructions when venting exceeds 15 foot run 1 Locate the 3 x 1 4 hex screws a...

Страница 45: ...Black 352 Z33ADTH Arch Door Frame Top Half Black 353T Fan Kit Blower Z33FK Fan Kit w Variable Speed Wall Mount Control Temperature Sensing 6000 P930 Blower Motor QLN657 1800 Z33FK MOTOR ZDV3318 Parts...

Страница 46: ...Frame Top Half Black 353T Fan Kit Blower Z36FK Fan Kit w Variable Speed Wall Mount Control Temperature Sensing 6000 081 Blower Motor QLN657 1800 Z36FK MOTOR Refractory Liners Z3622PRL Porcelain Refle...

Страница 47: ...00 150MP Hi Temp Millpac Sealant 840099 1000 214 Piezo Igniter 1244 17 MARK 21 1000 215 Pal Nut 18MMXI 5MM BLK 1364 03 1000 218 Switch Ivory 1451 001 1000 227 Cover Ivory 86001 001 1000 255 Orifice Br...

Страница 48: ...and other at risk individuals out of the room and away from hot surfaces Do not leave the fireplace remote control where it is accessible to children Termination Cap Safety All Units WARNING WHEN THE...

Страница 49: ...service or maintenance h damage repairs inoperation or inefficiency resulting from faulty installation or application i electricity or fuel costs or any increase in electricity or fuel cost whatsoever...

Отзывы: