background image

MCVP42   

 

 

 

 Parts List 

Fireplace Part Numbers 

MCVP42N 

(Millivolt) Fireplace Decorative rated, 
NG, Tempered Glass, Safety Screens 

MCVP42NH 

(Millivolt) Fireplace Heater rated, NG, 
Ceramic Glass, Safety Screens 

MCVP42NE 

(IPI) Fireplace Decorative Rated NG, 
Tempered Glass, Safety Screens 

MCVP42NHE 

(IPI) Fireplace Heater Rated NG, 
Ceramic Glass, Safety Screens 

MCVP42LP 

(Millivolt) Fireplace Decorative Rated 
LP, Tempered Glass, Safety Screens 

MCVP42LPH 

(Millivolt) Fireplace Heater Rated LP, 
Ceramic Glass, Safety Screens 

MCVP42LPE 

(IPI) Fireplace Decorative Rated LP, 
Tempered Glass, Safety Screens 

MCVP42LPHE 

(IPI) Fireplace Heater Rated LP, 
Ceramic Glass, Safety Screens 

MCVP42 Options  

M42LOG3 

Driftwood Log Set- 6 Pcs  
(Use with GT only) 

M42LOG4 

Oak Log Set- 8 Pcs  
(Use with LG only) 

VLBIT4 

Log Bits - Large Four Piece Kit 

VLBIT6 

Log Bits - Small Six Piece Kit 

MP42GT 

Glass Tray- Requires 10LBS Glass 

M42LG 

Log Grate 

42MVB-258

 

Pilot Shield - for MP42GT & M42LG

 

ZG5C 

Decorative Ember Glass 

–Bronze 5LB

 

RBCB1 

Cannonballs- Assorted size and colors 

ULK3 

Universal Light Kit 

3927ZDV-P779-1 

Bulb 10W 12V 64418 or [Sylvania 
58691] (light bulbs NOT covered under 
Warranty.) 

5143-P77912    

Lamp Assembly 58mm (light bulbs 
NOT covered under Warranty.) 

3927ZDV-P601 

Transformer MET60-1 

MCVP42 OPTIONS 

– MQ DEALER ONLY - 

MQ42LOG1 

Driftwood Log Set- 8pcs 
(Use with GT or LG) 

MQ42LOG2 

Oak Log Set- 7pcs 
(Use with GT or LG) 

MQSTONE 

Decorative Stones 

MQROCK2 

Rock Set Natural 

MQROCK3 

Rock Set Multi-Color 

MQEMBER 

Glowing Embers 

MQG5W 

Decorative Glass 1/2” White 5LB 

MQG5A 

Decorative Ember Glass Cobalt Blue 
5LB 

MQG5B 

Decorative Ember Glass 

– Black 5LB 

MQG5ZG 

Decorative Glass- Zircon Glacier Ice 
5LB 

Refractory Liners 

MP42RLT 

Refractory Liner Traditional  
(Use with LG only) 

MP42PL 

Porcelain Reflective Liner 
(Use with GT or LG) 

Child Safety Screens 

MP42CSSL 

Child Safety Screen (Large) 

MP42CSSS 

Child Safety Screen (Small) 

Door Glass 

42HB-310 

Tempered Glass-for Decorative 
Units 

42HB-311 

Ceramic Glass-for Heater Rated 
Units 

42MCVP-315T 

Tempered Glass-for Decorative 
Units 

42MCVP-315C 

Ceramic Glass-for Heater Rated 
Units 

46ZRB-123A 

Door Latch Assembly 

Replacement Burner Assembly / Burner 

42MP-200A 

Fireplace Burner  

42MP-BLPSI 

Burner Assembly- Propane c/w Valve 
System (MCVP42LP) 

42MP -BLPSIH 

Burner Assembly- Propane c/w Valve 
System (MCVP42LPH) 

42MP -BNGSI 

Burner Assembly- Natural Gas c/w Valve 
System (MCVP42N) 

42MP-BNGSIH 

Burner Assembly- Natural Gas c/w Valve 
System (MCVP42NH) 

42MP-BLPSIE 

Burner Assembly- Propane c/w Valve 
System (MCVP42LPE) 

42MP-BLPSIHE 

Burner Assembly- Propane c/w Valve 
System (MCVP42LPHE) 

42MP-BNGSIE 

Burner Assembly- Natural Gas c/w Valve 
System (MCVP42NE) 

42MP-BNGSIHE 

Burner Assembly- Natural Gas c/w Valve 
System (MCVP42NHE) 

Conversion Kit 

42MP-CKLP 

LP Conversion Kit for MCVP42 Millivolt 

42MP-CKLPH 

LP Conversion Kit for MCVP42H Millivolt 

42MP-CKNG 

NG Conversion Kit for MCVP42 Millivolt

 

42MP-CKNGH 

NG Conversion Kit for MCVP42H Millivolt 

42MP-CKLPI 

LP Conversion Kit for MCVP42 IPI

 

42MP-CKLPHI 

LP Conversion Kit for MCVP42H IPI 

42MP-CKNGI 

NG Conversion Kit for MCVP42 IPI

 

42MP-CKNGHI 

NG Conversion Kit for MCVP42H IPI 

Baffle Conversion Kit 

42MP-BCKNG 

NG Heater / upgrade Kit for MCVP42N / NE 
to MCVP42NH /NHE 

42MP-BCKLP 

LP Heater / upgrade Kit for MCVP42LP / 
LPE to MCVP42LPH /LPHE 

Accessories 

Z1MT 

Thermostat Millivolt Wall Mount 

Z80PT

 

Thermostat Programmable Digital 
Millivolt Wall Mount (1F80-40) 

Valve System Parts / Millivolt 

1000-P136WR 

Generator / Thermopile 

1001-P069SI 

Electrode Sparker 915.069 TC SIT 

1001-P216SI 

Thermocouple 290.216 TC SIT 

1001-P165SI

 

Orifice Pilot NG 977.165 TC SIT

 

1001-P167SI

 

Orifice Pilot LP 977.167 TC SIT

 

1001-P280SI

 

Tubing 24”

 

1001-P633SI

 

Valve Nova LP Hi/Lo 0820651

 

1001-P634SI

 

Valve Nova NG Hi/Lo 0820652

 

1001-P713SI

 

Pilot Burner LP 199.713 TC SIT

 

1001-P714SI

 

Pilot Burner NG 199.714 TC SIT

 

 
 

63

Содержание Atrium MCVP42LPH

Страница 1: ...on of R Co Inc 2340 Logan Ave Winnipeg Manitoba Canada R2R 2V3 Ph 204 632 1962 Printed in Canada May 5 2015 Part 42MCVP MAN14 For Propane Horizontal installations the venting must be an additional one...

Страница 2: ...ece Driftwood Log Set For use with GT Glass Tray 24 MQ42LOG1 8 Piece Driftwood Log Set For use with M42LG Log Grate 25 MQ42LOG2 7 Piece Oak Log Set For use with GT Glass Tray 26 MQ42LOG2 7 Piece Oak L...

Страница 3: ...ls 51 Configuration 3 Remote ON OFF Variable HI LO and Fan 52 Electronic Ignition Lighting Instructions 53 VENTING Vent Termination 54 General Vent Installation 55 Installation of Side Wall Venting 55...

Страница 4: ...oddlers young children and other at risk individuals out of the room and away from hot surfaces Do not leave the fireplace remote control where it is accessible to children Termination Cap Safety All...

Страница 5: ...ce 15 Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning ma...

Страница 6: ...in the living area outside the bedroom s The carbon monoxide detector shall comply with NFPA 720 B A carbon monoxide detector shall be located in the room that houses the appliance or equipment and sh...

Страница 7: ...stallations e g marble tile and the adhesives used to adhere this product to the walls can react with heat and cause odours It is recommended that you burn your gas fireplace or stove for a minimum of...

Страница 8: ...it with metal studs minimum 20 gauge Minimum of 1 2 DUROCK cement board this non combustible panel is ULC listed as a wall shield floor protector and fasten to the entire perimeter framing Use fibergl...

Страница 9: ...adian National Electrical Code in Canada An appliance must be grounded to the steel chassis of the home with 8 ga copper wire using a serrated or star washer to penetrate paint or protective coating t...

Страница 10: ...e of Fireplace Fireplace to be covered with Non Combustibles e g Concrete Board for Flat Wall appearance Qty 4 Nailing Tabs are located on flue side of fireplace Nailing Tab Framing Stud Drywall Non C...

Страница 11: ...of where the stand off locations are These stand offs are provided as indicators to illustrate the boundaries for framing Therefore no framing material is permitted to extend beyond these stand offs V...

Страница 12: ...MCVP42 Locating Your Appliance See Mantel Leg Clearances Instruction for the proper placement of fireplace MCVP42 Fireplace Dimensions ISLAND ALL UNITS MAY BE VENTED VERTICALLY PENINSULA 12...

Страница 13: ...additional one foot above the minimum vertical rise off the flue before going horizontal Framed fireplace opening 55 MIN for NG 67 MIN for LP Plus Rise of Per Foot 55 MIN for NG 67 MIN for LP Plus Ri...

Страница 14: ...FACE OF THE FIREPLACE MUST BE NON COMBUSTIBLE It is also recommended to attach Non combustible facing to framing Combustibles i e Drywall may be installed flush with top of Fireplace Side facing to be...

Страница 15: ...n Step Two Use Drywall to finish face of wall NOTE Drywall will be flush with fireplace face Step 3 A brick tile or other non combustible border may be applied over fireplace face to conceal border Na...

Страница 16: ...terial s that will not combust Check your local codes and regulations to determine whether your mantel is combustible or Non Combustible The advantage of a Non Combustible Mantel is that it can begin...

Страница 17: ...he full width and depth of the appliance must be used Carpet may extend 1 inch above the floor of the appliance Minimum Ceiling Height from bottom of fireplace 61 Top from Stand offs 0 Top of 90 Bend...

Страница 18: ...cal from top to bottom Hook lower clip onto glass door frame Press down and push upper clip under top glass door frame Screens shown locked in place Clips First install smaller end screen Then install...

Страница 19: ...Glass Heat Deflectors to install Porcelain Liners WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may re...

Страница 20: ...move Baffle Heater Rated Units or Deflectors Decorative Units Refer to Baffle Removal Deflector Removal sections of manual 2 Orient tabs in upper firebox as shown 3 Insert Liner into Firebox 4 Bend Ta...

Страница 21: ...o ledge at top of firebox Replace end screw first Replace 4 remaining screws ZCV42MCVP Deflector Removal Decorative Units To Remove Deflectors Remove 2 DT Screws holding each Deflector in place To Rep...

Страница 22: ...t Area Must Not Be Covered The following items can be used with the Glass Tray ULK3 Light Kit MQLOG1 MQLOG2 M42LOG3 RBCB1 Cannonballs VLBIT4 or VLBIT6 Decorative Glass MQSTONE MQROCK2 or MQROCK3 MQEMB...

Страница 23: ...ate to end of burner tray with screws To Remove 1 Remove screws holding Grate Assemblies in place 2 Remove screws holding Grate Plate in place 3 Remove from firebox Contents of Kit 1 2 Log Grates 2 2...

Страница 24: ...GT Glass Tray 2 3 4 5 6 8 7 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damag...

Страница 25: ...or failure to use only parts specifically approved with this appliance may result in property damage or personal injury 2 5 6 8 1 3 4 7 PILOT Place 350 Embers from M42LG in Burner Tray Place Insulati...

Страница 26: ...GT Glass Tray 2 3 4 5 6 7 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage o...

Страница 27: ...ailure to use only parts specifically approved with this appliance may result in property damage or personal injury 1 3 1 4 2 7 5 6 PILOT Place 350 Embers from M42LG in Burner Tray Place Insulation Wo...

Страница 28: ...ith GT Glass Tray 2 3 4 5 6 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage...

Страница 29: ...lure to use only parts specifically approved with this appliance may result in property damage or personal injury 1 8 1 2 3 4 5 6 7 8 PILOT Place 350 Embers from M42LG in Burner Tray Place Insulation...

Страница 30: ...ening Remove glass door first NOTE When using a remote control the 51 UHS Box must be used Batteries for Remote Receiver can be changed by lifting 51 UHS up through opening 51 UHS can be inserted remo...

Страница 31: ...black and red wires at transformer or plug black and red transformer wires together if 120V receptacle will be switch controlled REFER TO COMPONENT LOCATIONS SECTION OF MANUAL FOR TRANSFORMER PLACEME...

Страница 32: ...onged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Label all wires prior to disconnection when servicing contr...

Страница 33: ...bjects MQ Glass can be placed directly on Burner and on Glass Tray MQ Ember can be placed directly on Burner Only Lava Rock Supplied with Base Unit CANNOT be placed on Burner Place Lava Rock in channe...

Страница 34: ...ce Maximum amount 10lbs on Burner Tube and Burner Tray 15lbs on Glass Tray 25lbs Max total MQG5W Decorative Glass 1 2 White MQG5A Decorative Ember Glass Cobalt Blue MQG5B Decorative Ember Glass Black...

Страница 35: ...be used on some installations If sooting occurs change position of or remove affected objects MQEMBER To be placed directly on Burner and Burner Ports Place these glowing ember chunks randomly May be...

Страница 36: ...2 Engage door in lower latches at an angle of between 15 and 30 degrees 3 Swing door up and pull top latches over door lip at each corner 4 Replace Access Cover below Glass Door 30 15 WARNING Wait un...

Страница 37: ...glass Wear gloves Removal of Large Glass Doors 1 Remove the door by unlatching the 2 top latches Simply place 2 fingers in the grooves and pull and lift upward slightly 2 Once the top of the door is...

Страница 38: ...ny pressure testing of that system at test pressures in excess of 1 2 PSIG 3 5 KPa 9 The appliance must be isolated from the gas supply piping system by closing its individual shutoff valve during any...

Страница 39: ...rear center left hand side of the main burner If a flame has appeared then continue to depress the control knob for 20 seconds If the flame did not appear then continue to depress the red igniter butt...

Страница 40: ...ge Check generator with millivolt meter Take reading at generator terminals of gas valve Should read 325 millivolts minimum while holding valve knob depressed in pilot position and wall switch off Rep...

Страница 41: ...e main burner was never on Exercise caution when working within the area ALL WORK SHOULD BE PERFORMED BY A QUALIFIED AND CERTIFIED TECHNICIAN Monthly Flame Inspection It is recommended to turn on the...

Страница 42: ...lot Orifice See Pilot Conversion and Hi Lo valve regulator by following instructions supplied with the Conversion Kit Refer to Gas Specifications Chart for inlet pressures and input ratings Clock mete...

Страница 43: ...is stamped on the side of the injector near the top LPG injectors have a groove machined around their circumference near the top while NG injectors do not have a groove fig 4 Refer to the Appliance M...

Страница 44: ...Gas Conversion for Modulator PART C WARNING WARNING 44...

Страница 45: ...anual Then refer to Burner Removal instructions above to remove burner Remove fourteen 14 screws around edge of Burner Pan Carefully work the burner pan loose lift the assembly upward to remove it fro...

Страница 46: ...Switch Remote Receiver Module IPI Module Fan Control Module UHS Box Cover Backup Battery Pack Modulating Servo Motor Is an add on valve component that permits HI LO functionality to be controlled by t...

Страница 47: ...press the Thermostat Key The LCD display on the Transmitter will change to show that the room thermostat is ON and the set temperature is now displayed To adjust the set temperature press the Up or D...

Страница 48: ...or 1002 P910si Electrode Flame Sensor 35 Length 5 1002 P302si IPI Ignition Board 6 1002 P850si AC Wall Adapter 7 1002 P12BH Battery Pack 8 1002 P912si Wiring Harness 9 1001 P166si Orifice Pilot NG 62...

Страница 49: ...Configuration 1 Basic Manual HI LO and Manual ON OFF Capabilities 49...

Страница 50: ...and Manual HI LO Optional For units with remote HI LO capabilities a modulating servo is required to be installed on the valve The connectors to this servo must be connected to the Remote Harness as...

Страница 51: ...I or Millivolt system can be powered by the AC Adapter This is advantageous if you do not want to use batteries Simply connect the AC Adapter into the Remote Control Wiring Harness as per the diagrams...

Страница 52: ...Configuration 3 Remote ON OFF Variable HI LO Lights and Fan NOTE FAN IS NOT AVAILABLE ON 42MCVP UNITS ULK LIGHT KIT 52...

Страница 53: ...e department LIGHTING INSTRUCTIONS 1 Stop Read the above safety information on this label 2 Remove batteries from receiver and or Battery Backup Pack 3 Turn off all electric power to the fireplace 4 T...

Страница 54: ...ally L Clearance above paved sidewalk or a paved driveway located on public property 7 feet 2 1m minimum 3 M Clearance above highest point of exit on roof 18 inches 45cm N Clearance to perpendicular w...

Страница 55: ...f fireplace to center of vent see the Framing Your Gas Fireplace section Cut a hole through the wall allowing for a 12 x 12 inside diameter in combustible walls for wall thimble or a 9 diameter hole i...

Страница 56: ...ght of the system and the number of bends required 2 Having determined the vertical distance determine the maxi mum horizontal section allowed 3 Vent table has been established for 90 horizontal verti...

Страница 57: ...te comes in two sizes In the future Wall Thimble mount plate will be smaller than Termination Plate as a running change has been implemented Wall Thimble may need to be trimmed on outside mount plate...

Страница 58: ...Thimble Wall Thimble Wall Thimble 15 3 4 13 5 16 1 3 16 Termination New Wall Thimble Old Termination 13 3 4 13 5 16 3 16 New Wall Thimble New Termination Wall Thimble 13 3 4 New Termination Old Wall...

Страница 59: ...a Roof Flashing suitable to your roof slope over the vent Place the edge of the flashing plate that will be on the higher part of the roof slope under the shingles Both the sides and the lower edge l...

Страница 60: ...Clearances in horizontal venting Straight through roof support configuration b Flex bend configuration c Termination mounting 43ft Z58VT Restrictor Remove for Runs Under 15 Feet 60...

Страница 61: ...ownward vertical vent runs are NOT permitted NOTE MODELS EQUIPPPED WITH INTERMITTENT PILOT IGNITION Downward vertical vent runs are permitted however Cold Climate Switch Standing Pilot Mode must not b...

Страница 62: ...panded 5 Expanded Z58FK8 Flex Kit 5 8 Dia x 4 Unexpanded 8 Expanded Z58FK20 Flex Kit 5 8 Dia x 10 Unexpanded 20 Expanded Kits are complete with spring stand offs silicone ZDV5FC Flex Connector 5 Diame...

Страница 63: ...hild Safety Screen Large MP42CSSS Child Safety Screen Small Door Glass 42HB 310 Tempered Glass for Decorative Units 42HB 311 Ceramic Glass for Heater Rated Units 42MCVP 315T Tempered Glass for Decorat...

Страница 64: ...0 150MP Hi Temp Millpac Sealant 840099 1000 214 Piezo Igniter 1244 17 MARK 21 1000 215 Pal Nut 18MMXI 5MM BLK 1364 03 1000 218 Switch Ivory 1451 001 1000 227 Cover Ivory 86001 001 1000 255 Orifice Bra...

Страница 65: ...other than in a normal residential environment c damages caused by any unauthorized alteration or repair of the unit affecting its stability or performance d damages caused by improper matching or app...

Отзывы: