Dismantle the not worked
button
to change new one.
Fan stop
If everything normal, only the fan not work, use multi
‐
meter to check if voltage exist
terminal for fan.
If exist voltage, then
change the fan, if not exist voltage, then change sensor
LM2576T
‐
12V
or change the main board.
No Display or
incompletely
display
If led light up but no display or incompletely display, change the
Digital Tube
, or change the whole main board(display board)
No response
of active
function
Check if MENU function
S
‐
01 ~ S
‐
04
, adjust the sound active sensitivity to be higher(0~255), if not MENU data problem, then
change the microphone or change the whole main board
Led light up
but color not
normal
Change the corresponding color’s sensor
LM317S
on led board.
Some MENU
button not
work
Indicator light