background image

11-5. Transmit The Data Logger 

You can transmit the stored temperature to pc. The function can only be 
used when the unit is in LOG mode, and it can transmit all of the stored 
temperature one time. The function works as follows: 

 

While in LOG mode, press the trigger and then press the 

“down”

 arrow 

button until reach LOG 

“TrM”.

 

 

When LOG location “TrM” shows in the display, press “laser/backlight” 
button. A tone will sound and the LOG location will automatically change 
to “1”, all of the stored temperature transmit to pc. 
 

11-6. Wireless Transmit Function 

 

In the MAX, MIN, DIF, AVG mode, press the 

“USB”

 button to stir up 

the Wireless Transmit function, 

“USB”

 will be displayed on the upper 

right corner of the LCD.  
Press the USB button again; this function will be turned off.  

 

After the Wireless Transmit function is turned on, firstly connect the USB 
interface (RF 433MHz) to the computer and wireless transmitter and open 
the software on the computer, then the IR temperature readings on the 
Thermometer will be transmitted to the computer. 

 

Wireless Transmit is allowed to use within a 30m area. 

Note:

 Data will only be transmitted under SCAN state. 

Note: Measurement considerations 

Holding the meter by its handle, point the IR sensor toward the object 
whose temperature is to be measured.  
The meter automatically compensates for temperature deviations from 
ambient temperature. Keep in mind that it will take up to 30 minutes to 
adjust to wide ambient temperatures are to be measured followed by high 
temperature measurements, some time (several minutes) is required after 
the low (and before the high) temperature measurements are made. 
This is a result of the cooling process, which must take place for the IR 
sensor. 
 
 
 
 
 
 
 
 

Содержание MIT-371

Страница 1: ...IR Thermometer with Wireless USB Interface Product Code MIT 371 User Manual WWW MARMONIX CO...

Страница 2: ...Buttons 10 Measurement Operation 11 Data Logger 11 1 Storing Data 11 2 Infrared 11 3 Recalling Data 11 4 Log Clear Function 11 5 Transmit The Data Logger 11 6 Wireless Transmit Function 12 Battery Rep...

Страница 3: ...contact temperature measurement Type K temperature Measurement Dual laser sighting 150ms faster sampling time Wireless USB Interface RF 433Hz Unique flat surface modern housing design Automatic Data...

Страница 4: ...below Te focal point for each unit is 914mm 36 The spot sizes indicate 90 encircled energy CAUTION LASER RADIATION AVOID DIRECT EYE EXPOSURE MAXIMUM OUTPU 1Mw WAVELENGTH 630 670nm CLASS LASER PRODUCT...

Страница 5: ...ponse 8 14um Emissivity Digitally adjustable from 0 1 to 1 0 Over range Indication LCD will show OL OL Polarity Automatic no indication for positive polarity Minus sign for negative polarity Diode Las...

Страница 6: ...Auto obtain Emissivity 6 Lock and laser on symbols 7 High alarm and low alarm symbol 8 Temperature values for the MAX MIN DIF AVG HAL LAL LAL TK and LOG 9 Symbols for EMS MAX MIN DIF AVG HAL LAL TK An...

Страница 7: ...witching C F Lock ON OFF and Set Alarm 1 C F 2 LOCK ON OFF 3 Set Alarm Select the temperature units C or F by using C Fswitch To lock the unit on for continuous measurement slide the middle switch LOC...

Страница 8: ...e LCD IR temperature value will be in the middle of LCD and Type K temperature value is at the lower side of the LCD Contact the Type K probe to the object surface and test the temperature of same poi...

Страница 9: ...rs in the lower left corner A LOG location number will be shown below LOG and the stored temperature for that location will be display To move to another LOG location press the UP and Down keys 11 4 L...

Страница 10: ...urned off After the Wireless Transmit function is turned on firstly connect the USB interface RF 433MHz to the computer and wireless transmitter and open the software on the computer then the IR tempe...

Страница 11: ...ture of an object The unit s optics sense emitted reflected and transmitted energy which is collected and focused on to a detector The unit s electronics translate the information into a temperature r...

Страница 12: ...s It will measure the surface temperature of the glass instead Steam dust smoke etc can prevent accurate measurement by obstructing the unit s optics 14 3 Emissivity Emissivity is a team used to descr...

Страница 13: ...94 Snow 0 83 Plastic 0 85 to 0 95 Glass 0 90 to 0 95 Timber 0 90 Ceramic 0 90 to 0 94 Paper 0 70 to 0 94 Marble 0 94 Chromium oxides 0 81 Plaster 0 80 to 0 90 Copper oxides 0 78 Mortar 0 89 to 0 91 Ir...

Отзывы: