RISK OF ELECTRIC SHOCK! Always unplug the power cord before servicing the unit to avoid electric shock.
Troubleshooting Guide
WARNING
PROBLEM
PROBABLE CAUSE
SOLUTION
Compressor will not run
No voltage at wall receptacle
Check circuit breaker or fuse.
Service cord pulled out of wall receptacle Replace.
Low voltage causing compressor to cycle
on overload
Contact power company and confirm that voltage fluctuation
does not exceed 10% plus or minus from the nominal rating.
Power switch is in “Off” position
Turn switch on.
Inoperative control
Call for service (888-375-2938).
Compressor stuck
Call for service (888-375-2938).
Compressor windings open
Call for service (888-375-2938).
Compressor overload stuck open
Call for service (888-375-2938).
Relay lead loose
Call for service (888-375-2938).
Relay loose or inoperative
Call for service (888-375-2938).
Power cord disconnected from dispenser
Call for service (888-375-2938).
Faulty cabinet wiring
Call for service (888-375-2938).
Compressor runs but no
refrigeration
System out of refrigerant
Call for service (888-375-2938).
Compressor not pumping
Call for service (888-375-2938).
Restricted filter drier
Call for service (888-375-2938).
Restricted capillary tube
Call for service (888-375-2938).
Moisture in system
Call for service (888-375-2938).
Compressor short cycles
Erratic control thermostat
Call for service (888-375-2938).
Faulty relay
Call for service (888-375-2938).
Low voltage
Contact power company and confirm that voltage fluctuation
does not exceed 10% plus or minus from the nominal rating.
Compressor draws excessive wattage
Call service technician.
Compressor runs too much or
constantly
Temperature too low
Adjust temperature control.
Erratic control
Call service technician.
Abnormally high room temperature
Reduce room temperature or relocate dispenser.
Door or lid gaskets not sealing
Adjust or call for service (888-375-2938).
System undercharged due to leaks
Call for service (888-375-2938).
System undercharged from factory
Call for service (888-375-2938).
System overcharged
Call for service (888-375-2938).
System not clean
Call for service (888-375-2938).
Restricted filter drier
Call for service (888-375-2938).
Restricted capillary tube
Call for service (888-375-2938).
Noisy
Tubing vibrates
Call for service (888-375-2938).
Internal compressor noise
Call for service (888-375-2938).
Compressor vibrating on cabinet frame
Call for service (888-375-2938).
Beverage leaking or not
flowing
Tube kinked
Remove valve and pull tube straight through valve area.
Valve stuck
Clean valve and valve area or call for service (888-375-2938).