5.3.1.
Recommended procedure
1) Activate the Clean Test.
2) Proceed directly to the activation of STEP 3.
3) Check on the display the passage of the level switch status from OFF to ON.
4) Check the pressure of the rinse circuit (min 1.5 - max 2.0 bar).
5) Check for leaks along the entire circuit.
6) Proceed directly to the END of the test.
7) At this point the tank is under pressure, so check that the level remains at least for one
minute
8) If you see the level go down, check the tightness of the drain valve
9) If everything is regular, the dosers are checked.
10) Reactivate the Clean Test by going directly to STEP 3
11) Go to STEP 4, checking the level indication on the display and go to END as soon as it
changes from ON to OFF, in this way there will remain a head of water in the tank.
12) Activate STEP 1 and wait for the indication on the display to return to ON, if it does not
occur, check the detergent dispenser (rotation, draft, etc.)
13) Repeat steps 10 and 11
14) Activate STEP 2 and wait for the indication on the display to return to ON, if it does not
occur, check the rinse aid dispenser (rotation, draft, etc.)
15) Go to STEP 4 and wait for the complete emptying of the system.
Содержание ANGELO PO COMBISTAR FX
Страница 1: ...1 Rev 0 ...
Страница 6: ...Copyright by Servizio Clienti ANGELO PO Spa 6 1 COMMERCIAL MODEL NUMBER ...
Страница 7: ...Copyright by Servizio Clienti ANGELO PO Spa 7 FX Models table ...
Страница 10: ...Copyright by Servizio Clienti ANGELO PO Spa 10 OVEN CONNECTION DIAGRAM FX 61 G3 ...
Страница 14: ...Copyright by Servizio Clienti ANGELO PO Spa 14 2 FUNCTIONAL DIAGRAM COMBI OVEN 6 7 10 1 9 5 11 12 13 14 15 ...
Страница 19: ...Copyright by Servizio Clienti ANGELO PO Spa 19 2 4 Steam producing operation injectors code ...
Страница 21: ...Copyright by Servizio Clienti ANGELO PO Spa 21 ...
Страница 44: ...Copyright by Servizio Clienti ANGELO PO Spa 44 ...
Страница 46: ...Copyright by Servizio Clienti ANGELO PO Spa 46 Fuses on Power Board ...
Страница 61: ...Copyright by Servizio Clienti ANGELO PO Spa 61 ...
Страница 67: ...Copyright by Servizio Clienti ANGELO PO Spa 67 Functional diagram gas system ...
Страница 104: ...Copyright by Servizio Clienti ANGELO PO Spa 104 ...
Страница 151: ...Copyright by Servizio Clienti ANGELO PO Spa 151 PICTURE 7 PICTURE 8 PICTURE 5 PICTURE 6 ...
Страница 162: ...Copyright by Servizio Clienti ANGELO PO Spa 162 6 15 Roll In adjustment RX201 RX202 ...
Страница 163: ...Copyright by Servizio Clienti ANGELO PO Spa 163 ...