SWM1P™
9
* Connect the live wire (L) and the neutral wire (N) to the terminals of the
Marmitek sunblind module.
* Connect the black and the brown wire of the motor connection to
respectively the DN and UP terminal of the sun blind module.
* Connect the blue wire of the motor connection to the wire connector of the
neutral wires.
* Connect the yellow/green wire of the motor connection to the wire
connector of the earth wires.
* Connect the purple input wire of the sun blind module to the momentary
contact for the ON/UP control.
* Connect the white input wire to the pulse contact for the OFF/DOWN control.
* Isolate the grey input wire.
* Isolate the pink input wire.
* Connect the live wire (L) to the P-terminal of the momentary switch.
* Check if the motor’s direction of running matches with the commands for
Up/Down. (Up = ON, Down = OFF) Check this by sending the ON and OFF
commands through the mains to the sunblind module using an interface (for
instance: PRU512, PRU256, CM15Pro). If the direction of running does not
match the commands sent, then switch the motor connection of the brown
and the black wire on the sunblind module (DN and UP terminals). Then check
if the direction of running of the motor matches with the operation of the
Up/Down key of the momentary switch. Switch the white and the purple input
wires on the momentary switch if the direction of running does not match the
operation for Up/Down.
P
PROG.
N
DN
UP
L
SWM1P
Figure 3.