![Marmitek MS9470 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/marmitek/ms9470/ms9470_manual_1730039019.webp)
19
MS9470/MS9770/MS9970
5.6 DELAY TIMES
ARMING
When arming the security system by means of the remote controls KR21 or SH624 in the ARM AWAY mode, the system will
arm with a instantaneously (factory default). In case you want to arm the system delayed, you can program the base station
for a delay. (N.B.: Arming the system by means of the ARM AWAY button on the base station, always will result in a delayed
arming of the system).
ALARM SENSORS
When the security system is armed, sensors can activate the system either instantaneously or with a delay. This depends on
the settings of the SC2800 base station and the switch setting of the sensors. Refer to the list below for a complete
overview.
Every time you press a key you hear a short confirmation beep.
1. Set the mode switch to the INSTALL position: All indicators of occupied zones come on
2. Key in your 4 digit PIN code (factory default [0000] refer to 5.8)
3. Press key number 5
4. Press ENTER
5. Press 0 for instantaneous alarm
or
Press 1 for delayed alarm
6. Reset the mode switch to the RUN 1 or RUN 2 position: Zone indicators go out
OVERVIEW DELAY TIME:
SC2800 base station operation “instantaneous alarm”
Arming of the system with remote controls:
Instantaneous
Arming of the system with ARM AWAY button of base station:
Delay of one minute
Arming of the system with ARM HOME button of base station:
Instantaneous
Alarm activation by a DS10 door/window contacts:
Instantaneous when switch is in MIN position,
30 seconds when in MAX position
Alarm activated by an MS10 motion sensors:
Instantaneous
SC2800 base station operation “delayed alarm”
Arming of the system with remote controls:
Delay of one minute
Arming of the system with ARM AWAY button of base station:
Delay of one minute
Arming of the system with ARM HOME button of base station:
Delay of one minute
Alarm activation by a DS10 door/window contacts:
Instantaneous when switch is in MIN position,
30 seconds when in MAX position
Alarm activated by an MS10 motion sensors:
Delay of 30 seconds