MGT 2” 60M–600M NXT2 TWIN ALTERNATING
SYSTEM INFORMATION
5
SPECIFICATION CHART
SYSTEM SIZE
MODEL
60
90
120
150
210
240
270
300
450
600
VALVE SIZE (IN)
2
2
2
2
2
2
2
2
2
2
MAX CAPACITY (KILOGRAINS)
60
90
120
150
210
240
270
300
450
600
MIN CAPACITY (KILOGRAINS)
40
60
80
100
140
160
180
200
300
400
FLOWRATE (GPM)
CONTINUOUS FLOWRATE (GPM)
33
39
47
61
60
74
71
68
84
87
PEAK FLOWRATE (GPM)
49
54
64
80
77
97
94
91
105
110
BACKWASH & FAST FLUSH (GPM)
3.5
5
6
8
12
15
15
15
25
30
BRINE DRAW & RINSE (GPM)
1
1
1.2
1.5
2.8
3.2
3.2
3.2
4.7
4.7
BRINE TANK REFILL (GPM)
1
1
1
2
2
2
2
2
5
5
TIMER
SETTINGS
BACKWASH & FAST FLUSH (MIN)
10
10
10
10
10
10
10
10
10
10
BRINE DRAW & RINSE (MIN)
60
60
60
60
60
60
60
60
80
80
FAST FLUSH (MIN)
10
10
10
10
10
10
10
10
10
10
BRINE TANK REFILL (MIN)
10
15
20
13
18
20
23
25
15
20
SOFTENER
TANK
SIZE (IN)
13x54
14x65
16x65
18x65
21x62
24x72
24x72
24x72
30x72
36x72
GRAVEL (LBS)
0
30
35
40
80
120
120
120
225
400
RESIN (FT
3
)
2
3
4
5
7
8
9
10
15
20
FREEBOARD (IN)
16
21
21
24
18
30
25
21
22
23
BRINE SYSTEMS
EQUIPMENT
TANK SIZE
18x40
18x40
24x40
24x50
24x50
24x50
24x50
24x50
30x50
39x60
MAX SALT STORAGE (LBS)
270
270
530
630
540
510
490
410
640
1700
INJECTOR CODE
3
3
4
3C
4C
5C
5C
5C
6C
6C
INJECTOR COLOR
YEL
YEL
GRN
YEL
GRN
WHT
WHT
WHT
RED
RED
MAX
SALT DOSAGE- MAX (LBS)
30
45
60
75
105
120
135
150
225
300
REFILL TIME - MAX (MIN)
10
15
20
13
18
20
23
25
15
20
MIN
SALT DOSAGE- MIN (LBS)
12
18
24
30
42
48
54
60
90
120
REFILL TIME - MIN (MIN)
4
6
8
5
7
8
9
10
6
8
REGENERATION WASTE VOLUME (GAL)
126
156
188
228
366
520
536
544
860
1020
NOTES:
1. FLOW RATES
Continuous:
pressure loss does not exceed 15 psig.
Peak:
pressure loss does not exceed 25 psig
Backwash & Flush:
maximum flow to drain
Brine & Rinse:
Injector flow to drain
Brine Tank Refill:
flow to refill Brine Tank
2. SOFTENER TANK
Freeboard: distance in inches from surface of resin to top sealing flange of tank
3. SALT DOSAGE
Maximum 15 lbs./cu.ft. - regeneration efficiency: 2,000 grains/pound of salt
(factory setting)
Maximum 6 lbs./cu.ft. - regeneration efficiency: 3,000 grains/pound of salt
4. REGENERATION WASTE VOLUME -
Total gallons water discharged per
regeneration
5. OPERATING LIMITS:
Minimum operating pressure is 30 psi.
Maximum operating pressure is 120 psi.
Standard units are designed to soften unheated water within the range of
35-100°F.
6. POWER
Power requirements are 120 Volt, 60 Hertz, Single Phase, 2 amps
noninterrupted.
7. SALT
Salt specifications are pelletized or solar salt, 99% pure, containing
less than 1% insolubles (see Brine Tank Installation on page 8)
Содержание MGT 120