Read Carefully
- These instructions are written to help you prevent
difficulties that might arise during installation of heaters. Studying the
instructions first may save you considerable time and money later.
Observe the following procedures, and cut your installation time to a
minimum.
TO REDUCE RISK OF FIRE OR ELECTRIC SHOCK:
1. Use minimum 60° copper wire only.
2. Heater air flow must be directed parallel to, or away from,
adjacent walls.
3. Observe wall, floor, and ceiling clearance requirements.
4. All wiring must conform to national and local electrical codes and
the heater must be grounded as a precaution against possible
electrical shock. Heater circuit must be protected with proper
fuses. See Table 1 on page 4.
5. The mounting structure and the anchoring hardware must be
capable of reliably supporting the weight of the heater and, if
used, the mounting bracket.
6. All electrical power must be disconnected at the main service box
before installing, inspecting, cleaning or servicing the heater. This
is a precaution to prevent serious electrical shock.
Installation & Maintenance Instructions
SAVE THESE INSTRUCTIONS
UH Series
Electric Space
Heater
WARNING
!
FILE #E21609
• Heater is shipped from factory wired for these wattages. Heater can be field adjusted to the other wattages. Refer to “Adjusting the Heat Output” on page 4.
•• 48" (1219mm) when heater air flow is between 45° downward and vertical.
Heater Rating and Voltage
•7500 W @ 240V
6250W @ 240V
5000W @ 240V
3750W @ 240V
1
25,598
21,331
17,065
12,799
Yes
6'
(1829)
11'
(3353)
6'
(1829)
8'
(2439)
18'
(5486)
••13"
(330)
1
19,198
15,990
12,799
9,598
Yes
6'
(1829)
11'
(3353)
6'
(1829)
8'
(2439)
18'
(5486)
••13"
(330)
•5625W @ 208V
4685W @ 208V
3750W @ 208V
2812W @ 208V
Horizontal Air
Throw, ft. (mm)
Min. Distance from
Mounting Hole to
Wall, in (mm)
Min.
Vertical Installation
Horizontal Installation
Mounting Height, ft. (mm)
Max.
Min.
Max.
Contactor
Built-in
Phase
SPECIFICATIONS: UH724ST
BTU per
Hr.
BTUH