The voltage and frequency of the
power supply must match the ventilator’s
specifications. An all-pole separation
device from the mains with a contact
gap of at least 3 mm is stipulated where
the ventilator is installed. Installation in humid rooms must be effected in
accordance with DIN/VDE 0100 T 701.
Light switch
All-pole
separation device
Ventilator
connection block
Wiring diagram
Technical data P11 (MP 100 S)
Protection class/type:
/ IP 24
Mains voltage:
230 V~50 Hz
Power input:
1,1–4,1 W
Sound pressure:
10–38 dB(A) 3m
Capacity:
10–83 m³/h
Max. supply pressure
110 Pa
Max. supply temperature: 40 °C
Max. duct:
6 m
Cleaning and maintenance
Clean the cover and the housing with control panel with a damp cloth.
Do not use aggressive cleaning agents!
We reserve the right to make technical changes.
15
16
17
The factory setting can be altered using button (12.5) and
(12.6) and, thus, adjusted to the applicable room situation.
To confirm the setting press button and (12.3 and 12.4), the
indicator lamp is now permanently illuminated. The settings mode ends
automatically after 10 seconds without entry.
The new type of humidity sensor registers the speed at which the
humidity in the room changes. If there is a rapid change it reacts to a
rise in room humidity caused by the user and switches on the ventilator.
Press button (12.7) to activate the humidity sensor. The LED lamp
illuminates to indicate that the sensor is active.
Activate the post-run timer (only with connected switched „L1“ phase)
by pressing button (12.8). The length of post-running time depends
on how long the ventilator was manually switched to the „Boost ventilation“
mode.
An active sensor is indicated by the illumination of the LED lamp.
Pressing any button displays the current operating status. To change
the setting you need to press button (12.5) and (12.6)
simultaneously for approx. 3 seconds. Press button (12.5) and
(12.6) for approx. 10 sec. to reactivate the factory setting.
Reattach the cover by turning clockwise.
Manual turn-on time (L1 active)
Post-run timer
0–5 min.
No post-running
5–10 min.
5 minutes
10–15 min.
10 minutes
15 + min.
15 minutes
ENGLISH
7