4 Remove outlet box cover by pulling downward while 

simultaneously pushing in side of cover at indicated point to 
release locking tab. Connect wire from wall switch to motor 
leads and light receptacle wires using approved wire connector -
white to white, black to black. Models A664IC, MM664IC, 
MM667IC, and MM667ICF Fan/Lights can be wired so that 
fan and light function independently of each other or wired so 
that when light is on the fan is on. (See the wiring diagrams 
on the next page.) Connect ground wire to green screw in 
outlet box. Replace outlet box cover insuring locking tab is 
engaged.

5. Use appropriate size duct for best performance. Model MM648

uses 3” duct.  Model MM748, MM748H, A664IC, MM664IC,
MM667IC, and MM667ICF uses 4” duct.

IMPORTANT: Be sure nothing obstructs the discharge of the fan. 
Take precautions to ensure that insulation does not get into duct
work or fan discharge opening.

NOTE: 

Numbers 6 thru 9 apply to models MM664IC, MM667IC and MM667ICF only.

6. Remove lens from grille. 

7. Place light plug into receptacle. Align the center hole in the reflector with the threaded screw hole in the grille mounting 

bracket. On models MM664IC, MM667IC, AND MM667ICF, align the off-center hole in the reflector with tab on the grille 
mounting bracket. Fasten using the screw supplied. See Fig. 1.

8. For models MM664IC and MM667IC, install type A-19, 100 watt (max) light bulb. For model MM667ICF, install one of the 

following 13 watt twin tube compact fluorescent lamps: 

• Sylvania F13DTT/27K

• Phillips PL-C 13W/27/USA

• Osram F13DTT/27K

• General Electric F13DBX23T4/SPX27

9.  Replace lens.

CAUTION:

BE SURE ALL WIRING COMPLIES WITH LOCAL AND NATIONAL ELECTRICAL CODES.

AND HOUSING IS PROPERLY GROUNDED.

-3-

FIG. 7

ROOF CAP

ROOF

ROUND
DUCT

Содержание MM648

Страница 1: ...ted construction 5 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating and Air Conditioning Engineers ASHRAE and the loc...

Страница 2: ...ling a 8 self tapping screw through the obround hole in the duct adapter and the small round hole in the housing 2 Attach housing to joist with screws or nails Housing is stamped to show a line at 3 4 for standard sheetrock and plaster and 3 8 for drywall See Fig 5 3 Run 120VAC 60Hz power leads from wall switch or timer to appropriate knockout in housing Use a BX or Romex connector on outlet box W...

Страница 3: ...ing obstructs the discharge of the fan Take precautions to ensure that insulation does not get into duct work or fan discharge opening NOTE Numbers 6 thru 9 apply to models MM664IC MM667IC and MM667ICF only 6 Remove lens from grille 7 Place light plug into receptacle Align the center hole in the reflector with the threaded screw hole in the grille mounting bracket On models MM664IC MM667IC AND MM6...

Страница 4: ...iability and buyer s exclusive remedy are limited to the repair of defective goods or the shipment of equivalent goods or the granting of a reasonable allowance on account of any defects as the seller may elect To obtain performance under this warranty you must 1 Contact the Marley Engineered Products Service Department at 1 800 642 HEAT between the hours of 9 00 a m and 5 00 p m C S T Monday thro...

Отзывы: