M
ARKET
F
ORGE
I
NDUSTRIES
, I
NC
.
35 G
ARVEY
S
TREET
E
VERETT
, MA 02149
T
EL
: 617-387-4100 T
ELEX
: 91-9494
F
AX
: 617-387-4456 O
UTSIDE
MA: 800-227-2659
Form No. S-4846
6
-
Rev. A
11/98
4-3
10. S
TEAM
ENTERS
COMPARTMENT
CONTINUOUSLY
. T
IMER
DIAL
NOT
TURNING
.
a. Constant steam position.
b. Faulty thermostatic
switch.
c. Faulty timer motor.
d. Faulty wiring.
a. Move knob to timing location.
b. Replace switch. See Subsection 5.4.8.
c. Replace timer. See Subsection 5.4.4.
d. Inspect condition of wire and tightness of
all connections. Correct as needed.
11. S
TEAM
CONTINUES
TO
FLOW
INTO
COMPARTMENT
AND
/
OR
BUZZER
FAILS
TO
SOUND
AT
END
OF
TIMER
SETTING
.
a. Timer contacts faulty.
b. Buzzer faulty.
c. Faulty wiring.
a. Replace timer. See Subsection 5.4.4.
b. Replace buzzer. See Subsection 5.4.9.
c. Inspect condition of wire and tightness of
all connections. Correct as needed.
12. B
URNERS
WILL
NOT
IGNITE
.
a. Manual gas shut-off valve
is not open.
b. Main POWER switch in
OFF position.
c. No water in boiler.
d. Electricity off.
e. Faulty hot surface igniter.
f. Faulty ignition module.
g. Faulty gas valve.
h. Faulty transformer.
a. Open.
b. Turn to ON position.
c. Check to be sure main power switch is on.
Check to be sure main water supply is on.
d. Turn on 110V electrical supply.
e. Check and replace.
f. Check and replace.
g. Check and replace.
h. Check and replace.
13. C
OLD
WATER
CONDENSER
DOES
NOT
FUNCTION
.
a. Main water line shut off.
b. Thermostat out of adjust-
ment or defective.
c. Loose coil nut.
d. No continuity in solenoid
coil.
a. Turn on.
b. Readjust for proper operation or replace if
defective.
c. Tighten coil nut.
d. Check coil for continuity. If open, replace.
14. B
OILER
OVERFILLS
WITH
WATER
.
Probes dirty.
Clean probes.
15. D
RAIN
WATER
TEMPERATURE
TOO
HIGH
.
a. Faulty 130°F thermostat
on the condenser tank.
b. Faulty tempering tank fill/
cool solenoid valve.
c. Faulty wiring.
a. Check 130°F thermostat. Replace if
necessary.
b. If 120V is verified at the solenoid cell, but
the valve fails to open, replace solenoid.
c. Check wiring.
4.
TROUBLESHOOTING (cont’d.)
TABLE 4-1 (cont’d.)
PROBLEM
PROBABLE CAUSE
REMEDY
4.3.1
Incoming Power
Before troubleshooting any of the electrical parts or
assemblies, verify that power is being supplied to the
cooker. Incoming power is connected at the boiler (or
direct-connected steam) control box located in the base
cabinet. With power connected to the cooker, an AC volt-
meter is used to measure 120 volts across L1 and L2. If
120 volts is present, and the cooker will not operate, the
fault lies within the electrical circuits of the cooker.