6
INSTALLATION
Utility Connections
WARNING
DO NOT USE APPLIANCE DURING PRO-
LONGED POWER FAILURE AS THE VENT
HOOD MAY NOT BE IN OPERATION RESULT-
ING IN INADEQUATE VENTING!
INITIAL PILOT LIGHTING
CAUTION
When lighting pilots and checking for leaks,
do not stand with your face close to the com-
bustion chamber.
Check for Gas Leaks
1. Remove the kick plate and the component cover at
the rear of the oven
2. Check pilot tubing and burner tubing for leaks at the
connectors with a soapy water solution.
3. Light the pilot as described above.
4. Turn the thermostat to any setting and the burner
should light.
5. Check the burner orifice elbow connection down-
stream of the valve with a soapy water solution.
6. Check the burner visually for blue flame. There should
be no yellow tips or soot. If yellow tipping occurs, call
an authorized service person to adjust the burner air
shutter.
DISCLAIMER
All MARKET FORGE INDUSTRIES, INC. appliances are
adjusted and tested before leaving the factory, effectively
matching them to sea level conditions. Adjustments and
calibrations to assure proper operation may be necessary
on installation to meet local conditions; low gas charac-
teristics, to correct possible problems caused by rough
handling or vibration during shipment, and are to be per-
formed only by qualified service personnel. These adjust-
ments are the responsibility of the customer and/or dealer
and are not covered by our warranty.