Operating Instructions
MARKET FORGE MODULAR STEAM GENERATOR OPERATING INSTRUCTIONS
WARNING:
The installation of this appliance is to be in accordance with the current CAN 1-B149. 1 of CAN1-
B149.2 - Installation Code for Gas Burning Appliances and Equipment and/or Local Codes.
WARNING:
All Electrical connections are to be made in accordance with CSA C22.1 Canadian Electrical Code
Part 1 and/or Local Codes.
Market Forge has two types of steam generators; one has an automatic drain, the other a manual one. To determine which
you have, open cabinet doors and you will see a control box with 2 switches and an indicator light. Instruction label on the
control box will identify the steam generator as being
automatic
or
manual.
DAILY OPERATING, SHUT DOWN & CLEANING INSTRUCTIONS FOR
AUTOMATIC STEAM GENERATORS
First check to be sure that:
A. WATER switch is in the off position.
B. WATER supply valve is OPEN.
C. ELECTRICITY is connected.
D. That STEAM is turned on.
E. Proceed with daily operating procedure.
DAILY OPERATING PROCEDURE
STEP 1 Flip WATER switch from OFF to ON.
STEP 2 Wait 6 minutes for water to fill in steam generator.
(Gauge glass should indicate approx. 2/3 full.)
STEP 3 Flip heat switch from ON to OFF and release back to ON. Indicator
light will come on immediately (This is necessary to manually reset
the unit.) This also turns on HEAT.
DAILY SHUT-DOWN AND CLEANING
STEP 1 Flip WATER switch OFF. (Indicator light will go out and
steam generator will automatically drain.)
STEP 2 After steam generator has completely drained, repeat Steps 1 & 2.
Water is to remain in steam generator until next day use.
STEP 3 Repeat Steps 1 & 2.
Water is to remain in steam generator until next day use
NOTES:
If generator is not to be in use for extended periods, (2-3 mos.) contact your authorized
service dealer, for it must be cleaned and drained completely. Then add PM-Plus as per
instructions on Bottle.
If steam generator does not automatically drain when water switch is shut off, open manual
drain by turning knob counter clockwise. Electric steam generators should be blown-down
and refilled after every 4 hours of operation.